Lennox Hearth MP04-VDLPM GAS Conversion Kits, Millivolt Appliances, 2 Installation Code

Page 28

GAS CONVERSION KITS

WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S IN- STRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COM- PLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT. THE QUALIFIED SERVICE AGENCY PERFORMING THIS INSTALLATION ASSUMES RESPONSIBILITY FOR THIS CONVERSION.

AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISÉSAVOIRLAJURIDICTION. SIL'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDEDECARBONEPEUTRÉSULTERLEDOMMAGES CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS DANS LES INSTRUCTIONS DE PROPRIÉTAIRE PROVISIONNÉES AVEC L'ÉQUIPEMENT.

In Canada:

THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1

AND .2 INSTALLATION CODE.

LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN1- B149.1 ET.2.

Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the neces- sary components needed to complete the task including labeling that must be affixed to en- sure safe operation.

Kit part numbers are listed here and the following steps detail the conversion procedure.

Step 1. Turn off the gas supply to the appliance.

Step 2. Carefully remove the logs. Exercise care so as not to break the logs.

Step 3. Refer to Figure 47.

Remove the burner assembly with attached venturi tube.

Natural To Propane Gas Conversion Kit

Models No.

Unit Type

Catalog No.

 

 

 

MPLDV30

millivolt

H6163

 

 

 

MPLDV35

millivolt

H6975

 

 

 

MPLDV40

millivolt

85L59

 

 

 

MPLDV45

millivolt

85L69

 

 

 

MPLDV30

electronic

H6166

 

 

 

MPLDV35

electronic

H6973

 

 

 

MPLDV40

electronic

H6168

 

 

 

MPLDV45

electrnoic

H6169

 

 

 

Propane to Natural Gas Conversion Kit

Model No.

Unit Type

Catalog No.

 

 

 

MPLDV30

millivolt

H6165

 

 

 

MPLDV35

millivolt

H6968

 

 

 

MPLDV40

millivolt

H6177

 

 

 

MPLDV45

millivolt

85L62

 

 

 

MPLDV30

electronic

H6170

 

 

 

MPLDV35

electronic

H6974

 

 

 

MPLDV40

electronic

H6172

 

 

 

MPLDV45

electronic

H6173

 

 

 

Millivolt Appliances

Step 4. SIT Systems - Refer to Figure 48 on page 29 and the instructions provided with the kit. Using a Torx T20, remove and discard the three pressure regulator mounting screws. Remove the pressure regulator, spring, pop- pet, diaphragm and bushing. Discard all removed components.

Ensure the rubber gasket installed on the back of the replacement pressure regulator is prop- erly positioned and install the new pressure regulator using the new screws supplied with the kit. Tighten screws to 25 In. lb. torque.

Burner Assembly

Orifice

Gas Valve

Assembly

Air Adjustment

Arm

Figure 47

28

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 28
Contents OTL Report No -F-47-5 MPLDV-35NM-2Table of Contents Millivolt And Electronic Models All ModelsModel Orifice size Nat PropTypical Locations LocationModel No Shelf Height inches mm Top Vent ApplicationVertical Vent Termination Clearances Appliance and Vent ClearancesVent Termination Clearances Horizontal Vent Termination ClearancesTypical Installation Sequence Detailed Installation StepsRouting GAS Line Horizontal Vent Termination ClearancesCanadian Installation US Installation Meter/regulator assembly= Clearance to service regulator vent outlet Feet 91cm Inches 30cmModel No 903 1035 419 9651030 1162 419 1092 FramingModel No These fireplaces must be vented directly to the outside Install the Vent SystemVertical Termination Systems Roof Vent Section Length Chart Vent / 45 Degree Starter Elbow Connection 10 1/2 Min 267 mmConnection Framing Dimensions for Roof Pitch 10-1/2 267 mm12/12 10-1/2Vertical Vent FIGURES/TABLES SupportBracket Ceiling Firestop/Spacer SV4.5VF Detail ViewHorizontal Outside Wall Termination System Plan the vent runTypical Horizontal Vent Installation Install firestop/spacer at ceilingFrame exterior wall opening Four incline channels on the collar refer to onInstall Firestop/Spacer at exterior wall Install the desired terminationMm as shown in Figure Slide the collars of the termination ontoHorizontal Vent FIGURES/TABLES Exterior Wall ThicknessConnection not Directly AT Appliance Connection Directly AT ApplianceWall Wall Firestop/SpacerWall Ceiling Firestop/Spacer SV4.5VFInstall the Outer Flex Pipe Pull and extend the inner flexible vent pipePull and extend the outer flexible vent pipe Route Flex VentField Wiring Millivolt Wiring See FigureElectronic Wiring See Figure After the wiring is complete, replace the cover plateConnecting GAS Line Installing the Glass Door and Optional Hood Installing the Glass DoorING Embers and Volcanic Stones MillivoltBurner Adjustments Burner AdjustmentFinishing Requirements Wall DetailsCold Climate Insulation Installation AccessoriesMantel Clearances Cat Cat. No. Model No. DescriptionGAS Conversion Kits .2 Installation CodeMillivolt Appliances Pilot Orifice Electronic Appliances Dexen Electronic Valves Model No Orifice size NaturalPage Page 850,043M REV. F 09/2008 West Taft Avenue Orange, CA