Note: Combustible wall finish materials and/or surround materials must not be allowed to be placed in direct contact with the area defined by the appliance front face (black sheet metal). Never allow combustible materials to overlap the appliance front face. See Figure 44 on page 25. Combustible mantle materials may be placed in front of
Vertical installation clearances to combustible mantels vary according to the depth of the mantel. See Figure 45. Mantels constructed of non- combustible materials may be installed at any height above the appliance opening; however, do not allow anything to hang below the hood.
|
| MANTEL CLEARANCES |
| ||
|
|
| Inches (mm) |
| |
|
|
|
| 12 (305) MANTEL |
|
|
|
|
| 10 (254) MANTEL |
|
|
|
|
| 8 (203) MANTEL |
|
18 |
|
|
| 6 (152) MANTEL |
|
(457) |
|
|
|
|
|
16 |
|
|
| 4 (102) MANTEL |
|
(406) | 14 |
|
|
| TOP OF |
| (356) | 12 |
| 2 (51) MANTEL | APPLIANCE |
|
| (305) | 10 |
|
|
|
|
| (254) | 8 |
|
|
|
|
| (203) |
|
Figure 45 |
|
|
|
|
|
COLD CLIMATE INSULATION
Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated in Figure 46.
Combustible Materials |
| |
Allowed In Shaded |
| Top View Of |
Area “Safe Zone” |
| |
| Fireplace | |
|
| |
12" |
|
|
| 45° | 5" |
|
| |
17" |
|
|
|
| Min. Distance |
|
| |
Side |
| Side Wall |
|
| |
Wall | Side |
|
| Wall | Min. Distance To |
14" |
| |
| Unprotected Side Wall |
Figure 46
For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked or stuffed with unfaced fiberglass insulation. In cold climates, if the fireplace is being installed on a cement slab, a sheet of plywood or other raised platform can be placed underneath to prevent conducting cold up into the room. It also helps to sheetrock inside surfaces and tape for maximum air tightness and caulk firestops.
INSTALLATION ACCESSORIES
Listed Secure Vent™Components
Cat.No. | Model No. | Description |
**94L10 | SV4.5HTSS | Horizontal Small Square |
|
| Termination with |
|
| Firestop/Spacer (96K80) |
|
| and Adapter (74L61) |
**98L27 | SV4.5HTSSL | Horizontal Small Square- |
|
| Long Termination with |
|
| Firestop/Spacer (96K80) |
|
| and Adapter (74L61) |
**May be used with 30" and 35" models only.
Se
a
lant
Listed Secure Flex™Components
Cat. | Model | Description | |
No. | No. | ||
| |||
10K81 | SFMP | Mil Pac Black | |
|
| Sealant | |
89L40 |
| Mil Pac Black | |
|
| Sealant - Bulk Pack 12 | |
91L66 | Gear Clamp 4.5in. (114 mm) for | ||
|
| Flex (6 pieces) | |
91L67 | Gear Clamp 7.5 in. (190.5 mm) | ||
|
| for Flex (6 pieces) | |
H2248 | SF4.5HF | Firestop/Spacer - 10 Pack | |
|
| Horizontal | |
H2249 | SF4.5VF | Firestop/Spacer - 10 Pack | |
|
| Vertical | |
|
|
|
26
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.