Lennox Hearth MP54-VDLPM Cold Climate Insulation, Installation Accessories, Mantel Clearances

Page 26

Note: Combustible wall finish materials and/or surround materials must not be allowed to be placed in direct contact with the area defined by the appliance front face (black sheet metal). Never allow combustible materials to overlap the appliance front face. See Figure 44 on page 25. Combustible mantle materials may be placed in front of non-combustible facing materials, as shown in Figure 45.

Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with these exceptions: they must not cover any portion of the glass or hood; they may cover any portion of the top radiant panel or the air gaps surrounding the top radiant panel up to the installed hood.

Vertical installation clearances to combustible mantels vary according to the depth of the mantel. See Figure 45. Mantels constructed of non- combustible materials may be installed at any height above the appliance opening; however, do not allow anything to hang below the hood.

 

 

MANTEL CLEARANCES

 

 

 

 

Inches (mm)

 

 

 

 

 

12 (305) MANTEL

 

 

 

 

 

10 (254) MANTEL

 

 

 

 

 

8 (203) MANTEL

 

18

 

 

 

6 (152) MANTEL

 

(457)

 

 

 

 

 

16

 

 

 

4 (102) MANTEL

 

(406)

14

 

 

 

TOP OF

 

(356)

12

 

2 (51) MANTEL

APPLIANCE

 

 

(305)

10

 

 

 

 

 

(254)

8

 

 

 

 

 

(203)

 

Figure 45

 

 

 

 

 

COLD CLIMATE INSULATION

Combustible materials may project beyond the sides of the fireplace opening as long as they are kept within the shaded areas illustrated in Figure 46.

Combustible Materials

 

Allowed In Shaded

 

Top View Of

Area “Safe Zone”

 

 

Fireplace

 

 

12"

 

 

 

45°

5"

 

 

17"

 

 

 

 

Min. Distance

 

 

8-1/4" To Protected

Side

 

Side Wall

 

 

Wall

Side

 

 

Wall

Min. Distance To

14"

 

 

Unprotected Side Wall

Figure 46

For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked or stuffed with unfaced fiberglass insulation. In cold climates, if the fireplace is being installed on a cement slab, a sheet of plywood or other raised platform can be placed underneath to prevent conducting cold up into the room. It also helps to sheetrock inside surfaces and tape for maximum air tightness and caulk firestops.

INSTALLATION ACCESSORIES

Listed Secure Vent™Components

Cat.No.

Model No.

Description

**94L10

SV4.5HTSS

Horizontal Small Square

 

 

Termination with

 

 

Firestop/Spacer (96K80)

 

 

and Adapter (74L61)

**98L27

SV4.5HTSSL

Horizontal Small Square-

 

 

Long Termination with

 

 

Firestop/Spacer (96K80)

 

 

and Adapter (74L61)

**May be used with 30" and 35" models only.

Se

a

lant

Listed Secure Flex™Components

Cat.

Model

Description

No.

No.

 

10K81

SFMP

Mil Pac Black Hi-Temperature

 

 

Sealant

89L40

SFMP-12

Mil Pac Black Hi-Temperature

 

 

Sealant - Bulk Pack 12

91L66

SF-GC4-6

Gear Clamp 4.5in. (114 mm) for

 

 

Flex (6 pieces)

91L67

SF-GC7-6

Gear Clamp 7.5 in. (190.5 mm)

 

 

for Flex (6 pieces)

H2248

SF4.5HF

Firestop/Spacer - 10 Pack

 

 

Horizontal (3-1-1 spacing)

H2249

SF4.5VF

Firestop/Spacer - 10 Pack

 

 

Vertical (1-1-1 spacing)

 

 

 

26

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Image 26
Contents OTL Report No -F-47-5 MPLDV-35NM-2Table of Contents Model Orifice size Millivolt And Electronic ModelsAll Models Nat PropModel No Shelf Height inches mm Typical LocationsLocation Top Vent ApplicationVent Termination Clearances Vertical Vent Termination ClearancesAppliance and Vent Clearances Horizontal Vent Termination ClearancesRouting GAS Line Typical Installation SequenceDetailed Installation Steps Horizontal Vent Termination Clearances= Clearance to service regulator vent outlet Feet 91cm Canadian Installation US InstallationMeter/regulator assembly Inches 30cm1030 1162 419 1092 Model No903 1035 419 965 FramingModel No Vertical Termination Systems Roof Install the Vent SystemThese fireplaces must be vented directly to the outside Vent Section Length Chart Connection 10 1/2 Min 267 mmVent / 45 Degree Starter Elbow Connection 12/12 Framing Dimensions for Roof Pitch10-1/2 267 mm 10-1/2Bracket Vertical Vent FIGURES/TABLESSupport Ceiling Firestop/Spacer SV4.5VF Detail ViewHorizontal Outside Wall Termination System Plan the vent runFrame exterior wall opening Typical Horizontal Vent InstallationInstall firestop/spacer at ceiling Four incline channels on the collar refer to onMm as shown in Figure Install Firestop/Spacer at exterior wallInstall the desired termination Slide the collars of the termination ontoHorizontal Vent FIGURES/TABLES Exterior Wall ThicknessWall Connection not Directly AT ApplianceConnection Directly AT Appliance Wall Firestop/SpacerWall Ceiling Firestop/Spacer SV4.5VFPull and extend the outer flexible vent pipe Install the Outer Flex PipePull and extend the inner flexible vent pipe Route Flex VentElectronic Wiring See Figure Field WiringMillivolt Wiring See Figure After the wiring is complete, replace the cover plateConnecting GAS Line ING Embers and Volcanic Stones Installing the Glass Door and Optional HoodInstalling the Glass Door MillivoltFinishing Requirements Burner AdjustmentsBurner Adjustment Wall DetailsMantel Clearances Installation AccessoriesCold Climate Insulation Cat Cat. No. Model No. DescriptionMillivolt Appliances .2 Installation CodeGAS Conversion Kits Pilot Orifice Electronic Appliances Dexen Electronic Valves Model No Orifice size NaturalPage Page 850,043M REV. F 09/2008 West Taft Avenue Orange, CA