Lennox Hearth MP03-VDLPM, MN04-VDLPM, MN03-VDLPM, MP54-VDLPM Cat. No. Model No. Description

Page 27

INSTALLATION ACCESSORIES CONTINUED

Listed Secure Vent™Components

Cat.No.

Model No.

Description

H1968

SV4.5HT-2

Horizontal Square Termination

 

 

with Firestop/Spacer (96K80)

 

 

and Adapter (74L61)

H2152

SV4.5CGV-1

Vertical Termination

H4687

SV4.5CTS

Chase Top Term. Square

H4716

SV4.5CTS-B

Chase Top Term. Square, Blk

H4717

SV4.5CTS-TC

Terra Cotta Termination

77L70

SV4.5L6

6 inch (152 mm) Vent Section

77L71

SV4.5L12

12 inch (305 mm) Vent

Section

 

 

77L72

SV4.5L24

24 inch (610 mm) Vent

Section

 

 

77L73

SV4.5L36

36 inch (914 mm) Vent

Section

 

 

77L74

SV4.5L48

48 inch (1219 mm) Vent

Section

 

 

77L75

SV4.5LA

Telescopic Section

77L76

SV4.5E45

45 Degree Elbow

77L77

SV4.5E90

90 Degree Elbow

The following flashings come packaged with a storm collar.

77L78

SV4.5F

Flat Roof Flashing

77L79

SV4.5FA

1/12 to 7/12 Adjust. Flashing

77L80

SV4.5FB

7/12 to 12/12 Adjust. Flashing

77L81

SV4.5SC6

Storm Collars (6 collars/box)

H6183

SV4.5HF5

Firestop/Spacer Horizontal

 

 

(5-1-1 spacing)

H6184

SF4.5HF5

Firestop/Spacer Flex Horizontal

 

 

(5-1-1 spacing)

H2247

SV4.5VF

Firestop/Spacer - 10 Pack

 

 

Vertical (1-1-1 spacing)

96K93

SV4.5SU

Support Strap

96K94

SV4.5RSA

Attic Insulation Shield

96K92

SV4.5SP

Support Plate

87L02

SV4.5

Termination Guard

 

HGS

 

99L03

SV4.5HRK36

Horizontal Riser Kit 36"

99L02

SV4.5HRK14

Horizontal Riser Kit 14"

Listed Secure Flex™Components

Cat.

Model

Description

No.

No.

 

These termination kits include firestop/spacer, gear clamps and flex adapter.

H1969

SF4.5HT-2

Horizontal Square Termination

 

 

without Flex

77L87

SFKIT12

Flex Square Term. with 12 in.

 

 

(305 mm of *compressed Flex

77L88

SFKIT18

Flex Square Term. with 18 in.

 

 

(457 mm) of *compressed Flex

77L89

SFKIT24

Flex Square Term. with 24 in.

 

 

(610 mm) of *compressed Flex

77L90

SFKIT36

Flex Square Term. with 36 in.

 

 

(914 mm) of *compressed Flex

77L91

SFKIT48

Flex Square Term. with 48 in.

 

 

(1219 mm) of *compressed Flex

56L74

SFVT30

Vertical Termin. for Flex (flat to

 

 

6/12) with Flex Adapter, section

 

 

of rigid vent, roof support collar

 

 

assembly, roof flashing and

 

 

storm collar.

56L75

SFVT45

Vertical Termin. for Flex (6/12 to

 

 

12/12) with Flex Adapter section

 

 

of rigid vent, roof support collar

 

 

assembly, roof flashing and

 

 

storm collar.

60L10

SF-18

18 ft. (5.49 m) *compressed Flex

98K03

SF-12

12 ft.(3.66 m) *compressed Flex

Cat. No. Model No. Description

These termination kits include firestop/spacer, gear clamps and flex adapter.

**94L09

SF-HTSS

Horizontal Small Square

 

 

Termination without Flex

**94L04

SFKIT12SS

Flex Small Square Term. with

 

 

12 in. (305 mm of

 

 

*compressed Flex

**94L05

SFKIT18SS

Flex Small Square Term. with

 

 

18 in. (457 mm) of

 

 

*compressed Flex

**94L06

SFKIT24SS

Flex Small Square Term. with

 

 

24 in. (610 mm) of

 

 

*compressed Flex

**94L07

SFKIT36SS

Flex Small Square Term. with

 

 

36 in. (914 mm) of

 

 

*compressed Flex

**94L08

SFKIT48SS

Flex Small Square Term. with

 

 

48 in. (1219 mm ) of

 

 

*compressed Flex

Cat. No.

Model No.

Description

H1988

CTSA-33

Chase Top Shroud Kit,

 

 

Arch Top 3 x 3

H1985

CTSO-33

Chase Top Shroud Kit,

 

 

Open Top 3 x 3

H1987

CTSO-44

Chase Top Shroud Kit,

 

 

Open Top 4 x 4

H1986

CTSO-46

Chase Top Shroud Kit,

 

 

Open Top 4 x 6

H5820

4.5HTSK

Termnation Shroud Kit

*All compressed flex vents can be expanded up to two times. **May be used with 30" and 35" models only.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

27

Image 27
Contents MPLDV-35NM-2 OTL Report No -F-47-5Table of Contents Nat Prop Millivolt And Electronic ModelsAll Models Model Orifice sizeTop Vent Application Typical LocationsLocation Model No Shelf Height inches mmHorizontal Vent Termination Clearances Vertical Vent Termination ClearancesAppliance and Vent Clearances Vent Termination ClearancesHorizontal Vent Termination Clearances Typical Installation SequenceDetailed Installation Steps Routing GAS LineInches 30cm Canadian Installation US InstallationMeter/regulator assembly = Clearance to service regulator vent outlet Feet 91cmFraming Model No903 1035 419 965 1030 1162 419 1092Model No Install the Vent System These fireplaces must be vented directly to the outsideVertical Termination Systems Roof Vent Section Length Chart 10 1/2 Min 267 mm Vent / 45 Degree Starter Elbow ConnectionConnection 10-1/2 Framing Dimensions for Roof Pitch10-1/2 267 mm 12/12Ceiling Firestop/Spacer SV4.5VF Detail View Vertical Vent FIGURES/TABLESSupport BracketPlan the vent run Horizontal Outside Wall Termination SystemFour incline channels on the collar refer to on Typical Horizontal Vent InstallationInstall firestop/spacer at ceiling Frame exterior wall openingSlide the collars of the termination onto Install Firestop/Spacer at exterior wallInstall the desired termination Mm as shown in FigureExterior Wall Thickness Horizontal Vent FIGURES/TABLESWall Firestop/Spacer Connection not Directly AT ApplianceConnection Directly AT Appliance WallCeiling Firestop/Spacer SV4.5VF WallRoute Flex Vent Install the Outer Flex PipePull and extend the inner flexible vent pipe Pull and extend the outer flexible vent pipeAfter the wiring is complete, replace the cover plate Field WiringMillivolt Wiring See Figure Electronic Wiring See FigureConnecting GAS Line Millivolt Installing the Glass Door and Optional HoodInstalling the Glass Door ING Embers and Volcanic StonesWall Details Burner AdjustmentsBurner Adjustment Finishing RequirementsInstallation Accessories Cold Climate InsulationMantel Clearances Cat. No. Model No. Description Cat.2 Installation Code GAS Conversion KitsMillivolt Appliances Model No Orifice size Natural Pilot Orifice Electronic Appliances Dexen Electronic ValvesPage Page West Taft Avenue Orange, CA 850,043M REV. F 09/2008