Lennox Hearth LMDVT-3328-CNE Same manner as any SV4.5 vent component refer to Step E

Page 18

J. Assemble vent run to exterior wall - If not previously measured, locate the center of the vent at the exterior wall. Prepare an opening as described in Step B. Assemble the vent system to point where the terminus of the last section is located relative to the exterior surface to which the termination is to be attached as shown in

12-1/8"

7"

(178)

To help minimize water infiltration it is recommended that the Firestop/Spacer (SV4.5HF) be installed on the exterior side of the wall.

10-1/2"

SV4.5 HT-2 Termination

Figure 35 and Table 12 on Pages 18 & 19.

If the terminus of the last section is not within this distance, use the telescopic vent section SV4.5LA, as the last vent section. For wall thicknesses greater than that shown in Figure 35, refer to Table 12 on Page 19. This Table lists the additional venting components needed (in addition to the termination and adapter) for a particular range of wall thicknesses.

K. Attach termination adapter - Attach the adapter (adapter - SV4.5RCH - provided with the termination) to the vent section or telescoping vent section), elbow or appliance collar as shown

(308 mm)

5-1/8"

(130 mm)

Adapter

SV4.5RCH

6 to 48 inch Vent Section, Telescopic vent section, Elbow or Appliance Collar

(267mm)

3"

(76 mm)

1"

(25.4 mm)

Note: Centerline of Vent Piping is NOT the Same as the Centerline of the Framed Opening.

See Figure 14 on Page 9 for Min.

Distance to Base of Appliance.

Base of Appliance

18

in Figure 34 in the same manner as any SV4.5 vent component (refer to Step E).

L. Install Firestop/Spacer at exterior wall

-When using the square termination, install SV4.5HF (Secure Vent), SF4.5HF (Secure Flex) Firestop/Spacer over the opening at the exterior side of the framing, long side up, with the 3 inch spacer clearance at the top as shown in Figure 34, and nail into place.

(The Firestop/Spacer may also be installed over the opening at the interior side of framing).

M. Install the Square Termination (SV4.5HT-2)

Install the square termination - For the last step

,from outside the exterior wall, slide the collars of the termination onto the adapter (the outer inside the outer and the inner outside the inner) until the termination seats against the exterior wall surface to which it will be attached. Orient the housing of the termination with the arrow pointed upwards. Secure the termination to the exterior wall. The horizontal termination must not be recessed into the exterior wall or siding by more than the 1-1/4" (32 mm) as shown in Figure 35.

IMPORTANT

The vent termination is hot while in operation and for a period of time following the use of the fire- place. To prevent contact with hot surfaces, we recommend the use of a Termination Guard. See Items 12 and 13 on Page 31. This can be purchased at your local dealer.

Figure 34 - INSTALLING SQUARE HORIZONTAL TERMINATION (SV4.5HT-2)

Use silicone caulking to seal

Maximum Wall Thickness

the top and sides of the

 

10 in. (254 mm)

termination, up to the

 

Interior Surface of

Exterior Surface of Siding

underlayment, stucco, or

masonry wall surface.

Finished Wall

Exterior Surface of

 

 

Maximum Extent of

Framing

Siding

 

6 in. to 9-1/4 in.

 

Vent Run Sections

Caulk

 

 

Relative to Exterior

(152 to 235 mm)

 

 

Surface of Framing

 

 

 

Last Vent Section.

 

 

 

Use Telescopic Vent

 

 

 

Section (SV4.5LA), If

 

 

 

Necessary

SV4.5 HT-2

 

 

 

Termination

Caulk

 

SV4.5 HT-2

 

 

 

 

 

 

Termination

 

 

 

Adapter

 

 

 

SV4.5RCH

1-1/4” Maximum Recess of

 

 

 

 

 

 

Square Termination

Stucco

 

 

into Exterior Finishing Material

 

vFor thicknesses greater

 

 

 

 

 

 

than 10", see Table 12

 

 

Venting Connection and Exterior Wall Recessing of the Horizontal Square

Figure 35

Termination (SV4.5HT-2).

 

 

 

 

Horizontal terminations have been designed to perform in a wide range of weather condi- tions. Our terminations meet or exceed industry standards.

When selecting the locations of your horizontal terminations, do not place the termina- tion where water from eaves and adjoining rooflines may create a heavy flow of cascad- ing water onto the termination cap. If the cap must be placed where the possibility of cascading water exists, it is the responsibility of the builder to direct the water away from the termination cap by using gutters or other means.

Take care to carefully follow the installation instructions for the termination, including the use of silicone caulking where required.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Image 18
Contents Vented GAS Fireplace Heaters Direct Vent Models 850,029M REV. G 05/2008OTL Report No -F-31-5 Table of Contents SIT Millivolt Honeywell MillivoltMassachusetts And New York City, NY Re- quirements Cold Climate InsulationLocation MassachusettsHorizontal Vent Termination Clearances Manufactured Home RequirementsVertical Vent Termination Clearances Vent Termination Clearances= Clearance to service regulator vent outlet Feet 91cm Canadian Installation US InstallationMeter/regulator assembly Inches 30cmPanel or louvers Minimum Clearances to CombustiblesAppliance and Vent Clearances Adjacent to itFraming Detailed Installation StepsTypical Installation Sequence Routing Gas LineThis center mark see Figure Fireplace specificationsFrom Vent Size Vertical Venting Through the CeilingNatural Fireplace Framing specificationsSchedule Black Iron Pipe Inside Diameter Inches PropaneInstall the Vent System General Information These fireplaces must be vented directly to the outsideCross Section Vertical Termination Systems Roof Vertical Straight InstallationVent Section Length Chart Effective Vent LengthVertical Offset Installation Attach vent components to each otherVertical Vent FIGURES/TABLES PitchIf the vent system extends more than 5 feet 524 Elbow Only 305 048 610 572 914 096 219 610 305 219 829 914 438Table B Maximum Minimum Feet Meter Ratio V to H ratio is524 610 305 048 219 572 829 914 096 438 Table CMaximum Minimum Feet Meter Table D + H1 Maximum MinimumTypical Horizontal Vent Installation See on Page 12 or onInstall Firestop/Spacer at exterior wall Same manner as any SV4.5 vent component refer to Step ESee on Page 9 for Min Feet Meter Horizontal Vent FIGURES/TABLESTable F Maximum 914Horizontal Vent Figures / Tables 524 305 Minimum524 Elbow Only 048 610 572 914Install the Outer Flex Pipe Flexible Vent SectionAttach Flex Vent to Termination Field Wiring Wiring Optional Forced Air Blower KitSee Figure Connecting Gas Line Schematic Representation OnlyChecking Appliance Opera- tion Control Compartment AccessLouver Panel Instructions Ref SIT and Honeywell Millivolt Appliance CheckoutInstall VERMICULITE, VOL Electronic Appliance CheckoutCanic STONE, Glowing Embers and Logs LOG SET Catalog Number H3366Shown here 1 through 6 and per the instructions on Model LMDV-4035 Catalog Number H3365Burner Adjustments Flame Appearance and sooting Installing the Glass DoorInstalling Glass Enclosure Panels Air Shutter Adjustment GuidelinesFinishing Requirements Wall Details Burner Air Shutter Adjustment ProcedureHood Installation Drywall Bracket / SpacerCat. No Model Description 12B12C Cat. No Open Top, Chase Top ShroudDescription Listed Secure Flex ComponentsLMDV-3328 & LMDV-3530 Models Only All compressed flex vents can be expanded up to two timesH2013 H2009H2011 H2010SIT Millivolt Gas Valve Adjusting KnobMillivolt Appliances SIT Systems Pilot for SIT Millivolt Gas ValveSeries Pilot Orifice Ignitor AssemblyElectronic Appliances Honeywell Systems 850,029M REV. G 05/2008 West Taft Avenue Orange, CA

LMDV-3530-CNM, LMDV-35 Series, LMDVR-3328-CNE, LMDV-4035-CNE, LMDV-4035-CPM specifications

Lennox Hearth products are renowned for their quality, efficiency, and innovative technologies that optimize the home heating experience. Among the standout offerings in their lineup are the LMDV-3530-CPM, LMDVR-3328-CPM, LMDV-3530-CNE, LMDVT-3328-CPM, and LMDVR-3328-CNM models. Each of these products embodies the brand's commitment to performance and design, making them a popular choice for modern homeowners.

The LMDV-3530-CPM gas fireplace boasts a contemporary aesthetic combined with powerful heating capabilities. It features a clean face design that enhances the viewing experience while maximizing warmth in the room. The unit is equipped with advanced technology that includes multi-speed blowers for efficient air circulation, allowing users to enjoy consistent heat throughout the space. Its variable flame and heat control options ensure that homeowners can customize their ambience and comfort levels according to their preferences.

Similarly, the LMDVR-3328-CPM model is designed for versatility and efficiency. Its modern fireplace insert converts existing masonry fireplaces into high-efficiency heating systems. Featuring a sleek design, this insert incorporates innovative venting technologies that enable it to operate in diverse installation configurations, enhancing both aesthetic appeal and functionality. Homeowners can appreciate the adjustable flame and fan speed settings, which provide tailored heating solutions.

The LMDV-3530-CNE model distinguishes itself through eco-friendly features. It employs advanced combustion technology that reduces emissions without sacrificing heat output. This model stands out as an environmentally responsible option, suitable for conscious consumers who wish to reduce their carbon footprint. Its easy-to-use controls and stylish design make it a favored choice among discerning homeowners.

The LMDVT-3328-CPM continues the trend of performance and versatility. This model combines traditional charm with modern efficiency, featuring a large viewing area that allows for an inviting flame display. The unit’s heat exchanger is designed for maximum heat transfer, ensuring that warmth is efficiently distributed throughout the room.

Lastly, the LMDVR-3328-CNM model is perfect for those seeking an efficient upgrade for their traditional fireplace. With its stunning design and advanced features, including optional remote control and programmable settings, this model takes convenience to new heights.

Overall, Lennox Hearth’s suite of models combines elegance, efficiency, and innovation, ensuring that homeowners can find the perfect heating solution to complement their living spaces. Each product is engineered with state-of-the-art technologies that reflect Lennox’s dedication to quality and customer satisfaction.