Lennox Hearth LMDVR-3328-CPM Millivolt Appliances SIT Systems, SIT Millivolt Gas Valve

Page 35

IMPORTANT

LE CANADA SEULEMENT

La conversion devra être effectuée conformément aux recommanda- tions des autorités provinciales ayant juridiction et conformément aux exigences du code d'installation CAN1-B149.1 ET.2.

Gas conversion kits are available to adapt the appliance from the use of one type of gas to the use of another. These kits contain all the necessary components needed to complete the task including labeling that must be affixed to ensure safe operation.

Kit part numbers are listed here and the following steps detail the conversion procedure.

Step 1. Turn off the gas supply to the appliance. Remove the front glass door/frame from the appliance. Access the control compartment.

Step 2. Carefully remove the logs. Exercise care so as not to break the logs.

Step 3. Locate the screws securing the burner assembly to the appliance. Remove the burner assembly and retain the securing screws.

Step 4. Millivolt Appliances - SIT Systems

a. See Figure 62 and the instructions provided with the kit. Using a Torx T20, tool or or standard flat screwdriver remove and discard the three pressure regulator mounting screws. Remove the pressure regulator, spring, poppet, diaphragm and bushing. Discard all removed components. Ensure the rubber gasket installed on the back of the replacement pressure regulator is properly positioned and install the new pressure regulator using the new screws supplied with the kit. Tighten screws to 25 In. lb. torque.

SIT Millivolt Gas Valve

Pressure

Regulator

Remove

These

Components

Figure 62

Pilot for

SIT Millivolt

Gas Valve

Pilot

Orifice

Figure 63

b. Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas.

c. Refer to Figure 63 and remove the pilot hood assembly to access the hexed pilot orifice. Remove and replace the orifice with the one provided with the kit.

Step 5. Millivolt Appliances

Honeywell Systems -

a. Convert the gas valve as follows

(see Figure 64 ): Remove the plastic protect- ing cap. Remove the gas type setting screw by turning it counterclockwise. Obtain the replacement gas type setting screw from the kit and screw it into place (red for propane and blue for natural gas). Tighten the gas type setting screw by turning it clockwise. Replace the plastic protecting cap.

Honeywell Millivolt Gas Valve

Adjusting Knob

Regulator Cap

Conversion screw

(blue natural gas;

red LP/propane gas)

Figure 64

b. Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for pro- pane gas.

c. Convert the pilot orifice as follows (see Figures 65 & 66 ):

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Note - Use extra care not to engage the orifice strip with the 7/16" open end wrench (contacting the orifice strip could cause strip distortion rendering the pilot inoperative). Also avoid wrench contact to any of the other pilot parts.

Use a 7/16" open end wrench and turn the pilot hex fitting counter-clockwise 1/4 turn. (See Figure 66).

Note - The orifice strip tab may be randomly located on any side of the hex fitting.

d.Push the orifice strip tab all the way against the hex fitting to align the appropri- ate gas type orifice (see Figures 65 & 66). The type of gas for which the pilot is set, is, the gas type shown on the tab.

e.Retighten, clockwise, the pilot hex fitting until the pilot hood aligns with the thermocouple and thermopile as indicated by the arrows shown in Figure 66.

Pilot for Honeywell Millivolt Gas Valve

Orifice Strip Tab Position Identification

For LP (propane gas) and Natural Gas

P

L

 

 

LP (propane) Gas Posi-

 

 

 

 

 

 

tion - 1/16 inch hole,

 

 

 

 

 

 

 

 

LP and red color shown

 

 

 

 

on tab.

 

 

 

 

Natural Gas Position

 

 

NA

T

- NAT shown on tab.

 

 

 

 

 

 

 

Top View of Hex Fiting and Orifice Strip Tab

Figure 65

Pilot for Honeywell Millivolt Gas Valve

(Loosening of Hex Fitting For

Orifice Strip Tab Positioning)

Hood

Hood

Alignment

 

7/16 in. Open End Wrench

Orifice

Strip Tab

Take care not to contact the orifice strip tab with the hex fitting wrench - distortion of the tab may render the pilot inoperative.

Figure 66

35

Image 35
Contents OTL Report No -F-31-5 Vented GAS Fireplace Heaters Direct Vent Models850,029M REV. G 05/2008 Table of Contents Honeywell Millivolt SIT MillivoltMassachusetts Cold Climate InsulationLocation Massachusetts And New York City, NY Re- quirementsVent Termination Clearances Manufactured Home RequirementsVertical Vent Termination Clearances Horizontal Vent Termination ClearancesInches 30cm Canadian Installation US InstallationMeter/regulator assembly = Clearance to service regulator vent outlet Feet 91cmAdjacent to it Minimum Clearances to CombustiblesAppliance and Vent Clearances Panel or louversRouting Gas Line Detailed Installation StepsTypical Installation Sequence FramingVent Size Vertical Venting Through the Ceiling Fireplace specificationsFrom This center mark see FigurePropane Fireplace Framing specificationsSchedule Black Iron Pipe Inside Diameter Inches NaturalCross Section Install the Vent System General InformationThese fireplaces must be vented directly to the outside Effective Vent Length Vertical Straight InstallationVent Section Length Chart Vertical Termination Systems RoofAttach vent components to each other Vertical Offset InstallationIf the vent system extends more than 5 feet Vertical Vent FIGURES/TABLESPitch Ratio V to H ratio is 610 305 219 829 914 438Table B Maximum Minimum Feet Meter 524 Elbow Only 305 048 610 572 914 096 219Table D + H1 Maximum Minimum Table CMaximum Minimum Feet Meter 524 610 305 048 219 572 829 914 096 438See on Page 12 or on Typical Horizontal Vent InstallationSee on Page 9 for Min Install Firestop/Spacer at exterior wallSame manner as any SV4.5 vent component refer to Step E 914 Horizontal Vent FIGURES/TABLESTable F Maximum Feet MeterHorizontal Vent Figures / Tables 048 610 572 914 Minimum524 Elbow Only 524 305Attach Flex Vent to Termination Install the Outer Flex PipeFlexible Vent Section See Figure Field WiringWiring Optional Forced Air Blower Kit Schematic Representation Only Connecting Gas LineSIT and Honeywell Millivolt Appliance Checkout Control Compartment AccessLouver Panel Instructions Ref Checking Appliance Opera- tionCanic STONE, Glowing Embers and Logs Install VERMICULITE, VOLElectronic Appliance Checkout Shown here 1 through 6 and per the instructions on LOG SETCatalog Number H3366 Catalog Number H3365 Model LMDV-4035Air Shutter Adjustment Guidelines Installing the Glass DoorInstalling Glass Enclosure Panels Burner Adjustments Flame Appearance and sootingDrywall Bracket / Spacer Burner Air Shutter Adjustment ProcedureHood Installation Finishing Requirements Wall Details12C Cat. No Model Description12B Open Top, Chase Top Shroud Cat. NoAll compressed flex vents can be expanded up to two times Listed Secure Flex ComponentsLMDV-3328 & LMDV-3530 Models Only DescriptionH2010 H2009H2011 H2013Pilot for SIT Millivolt Gas Valve Adjusting KnobMillivolt Appliances SIT Systems SIT Millivolt Gas Valve850,029M REV. G 05/2008 West Taft Avenue Orange, CA Pilot Orifice Ignitor AssemblyElectronic Appliances Honeywell Systems Series

LMDV-3530-CNM, LMDV-35 Series, LMDVR-3328-CNE, LMDV-4035-CNE, LMDV-4035-CPM specifications

Lennox Hearth products are renowned for their quality, efficiency, and innovative technologies that optimize the home heating experience. Among the standout offerings in their lineup are the LMDV-3530-CPM, LMDVR-3328-CPM, LMDV-3530-CNE, LMDVT-3328-CPM, and LMDVR-3328-CNM models. Each of these products embodies the brand's commitment to performance and design, making them a popular choice for modern homeowners.

The LMDV-3530-CPM gas fireplace boasts a contemporary aesthetic combined with powerful heating capabilities. It features a clean face design that enhances the viewing experience while maximizing warmth in the room. The unit is equipped with advanced technology that includes multi-speed blowers for efficient air circulation, allowing users to enjoy consistent heat throughout the space. Its variable flame and heat control options ensure that homeowners can customize their ambience and comfort levels according to their preferences.

Similarly, the LMDVR-3328-CPM model is designed for versatility and efficiency. Its modern fireplace insert converts existing masonry fireplaces into high-efficiency heating systems. Featuring a sleek design, this insert incorporates innovative venting technologies that enable it to operate in diverse installation configurations, enhancing both aesthetic appeal and functionality. Homeowners can appreciate the adjustable flame and fan speed settings, which provide tailored heating solutions.

The LMDV-3530-CNE model distinguishes itself through eco-friendly features. It employs advanced combustion technology that reduces emissions without sacrificing heat output. This model stands out as an environmentally responsible option, suitable for conscious consumers who wish to reduce their carbon footprint. Its easy-to-use controls and stylish design make it a favored choice among discerning homeowners.

The LMDVT-3328-CPM continues the trend of performance and versatility. This model combines traditional charm with modern efficiency, featuring a large viewing area that allows for an inviting flame display. The unit’s heat exchanger is designed for maximum heat transfer, ensuring that warmth is efficiently distributed throughout the room.

Lastly, the LMDVR-3328-CNM model is perfect for those seeking an efficient upgrade for their traditional fireplace. With its stunning design and advanced features, including optional remote control and programmable settings, this model takes convenience to new heights.

Overall, Lennox Hearth’s suite of models combines elegance, efficiency, and innovation, ensuring that homeowners can find the perfect heating solution to complement their living spaces. Each product is engineered with state-of-the-art technologies that reflect Lennox’s dedication to quality and customer satisfaction.