Lennox Hearth LMDV-4035-CNM, LMDVT-3328-CPM Install the Outer Flex Pipe, Flexible Vent Section

Page 22

Vertical or Horizontal Venting Using Secure Flex Kits and Components

Secure Flex venting kits and components may be used in any venting application in place of rigid Secure Vent (SV4.5) direct vent components. All restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venting. Secure Flex kits may not be modified; also, under no circumstances may separate sections of flex pipe be joined together.

Using adapter (SV4.5RF), Secure Flex kits may be added to the end of a vent run made up of rigid Secure Vent (SV4.5) vent sections provided that doing so does not violate any of the venting length, height, routing, horizontal to vertical ratio requirements or clearance considerations detailed in this manual.

Secure Flex kits come with an adapter that can be fitted to the inclined channel end of the last Secure Vent (SV4.5) vent section in a rigid system in the exact same fashion as any other Secure Vent section. Align the dimpled

Note: Outer Pipe Is Pulled Away To Show The Detail of The Inner Pipe

APPLY ONLY MIL-PAC BLACK HIGH TEMPERATURE SEALANT (Cat. No. 10K81) to the outside surface of both collars of the adapter (be especially careful to fill the grooves of the outer collar to be covered by the flexible pipe) and slide flexible pipe over inner and outer adapter collars.

1 3/4 inch (44 mm) Flexible PipeandAdapterOuterCollar Overlap

Adapter (SV4.5RF)

Figure 43

Attach Adapter to Appliance

Collar, or Secure Vent Sections

Flex Vent

Securing Screw - 3 Places Equidistant (equally spaced) Just Below Gear Clamp)

Gear Clamps

1 3/4 in. (44 mm) Flexible PipeandAdapterInnerCollar Overlap

Securing Screw

-3 Places, 120° apart (equally spaced) Just Below Gear Clamp

22

end of the adapter over the previously installed section or appliance collar, adjusting the radial alignment until the four locking dimples of the adapter are aligned with the inlets of the four incline channels of the last vent section or collar. Push on the adapter until it fully engages, then twist the adapter clockwise running the dimples down and along the incline channels until they seat at the end of the channels.

Attach the flexible vent to the adapter as fol- lows (see also Figure 43):

A. Install the Inner Flex Pipe -

1.Install the small gear clamp loosely around the inner flexible vent pipe, push it back out of the way.

2.Apply a bead of Mill-Pac Black (700° F) high temperature sealant - Catalog No. 10K81 to the inner adapter collar, approximately 1/2 inch from the end.

3.Pull and extend the inner flexible vent pipe.

4.Slide the inner flex pipe over the adapter col- lar. Ensure the flexible vent pipe completely engages the adapter collar to a distance of 1 3/4 inches from the end, and that it is free

from damage or tears.

5. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adapter inner collar approximately 3/4 inch from the end of the flex.

6. Installthreescrews120degreesapartthrough the flexible vent pipe and into the adapter collar just below the gear clamp to provide additional security to the connection.

B. Install the Outer Flex Pipe -

1.Install the large gear clamp loosely around the outer flexible vent pipe, push it back out of the way.

2.Apply a bead of Mill-Pac Black (700° F) high temperature sealant - Catalog No. 10K81) to the outer adapter collar; to the grooves of the collar which extend approximately 1 inch from the end and to the flat surface, approximately 1-3/8 inches from the end.

3.Pull and extend outer flexible vent pipe.

4.Slide the outer flex pipe over the adapter col- lar. Ensure the flexible vent pipe completely engages the adapter collar to a distance of 1-3/8 inches from the end, and that it is free from damage or tears.

5. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adapter outer collar approximately 3/4 inch from the end of the flex.

6.Install three screws 120 degrees apart through the flexible vent pipe and into the adapter collar just below the gear clamp to provide additional security to the connec- tion.

C.Route Flex Vent -

Ensure that the flex vent is properly routed to provide the required clearance. Do not allow the flexible vent to bend in a radius tighter than 5" (127 mm). Refer to Figure 44. Space out the internal flex vent spacers evenly - approximately every 6 inches - and avoid kinking of inner pipe. Support horizontal sections of flex with metal straps at 2 foot (0.61 m) intervals.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

D.Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceiling, a firestop / spacer is required: use the SF4.5 VF firestop / spacer for ceilings and the SF4.5 HF firestop / spacer for walls. See the appropriate sectionsand Figuresshown throughoutthe vent- ing section for their installation requirements.

Flexible Vent

Section

 

5” (127 mm)

 

Radius

Figure 44

Minimum

 

E. Attach Flex Vent to Termination -

Secure Flex components can be purchased separately and attached to bulk lengths of Se- cure Flex flexible tubing cut to size at the job site. Secure the flexible vent to the Secure Flex terminations in the same manner (see Figure

43)as it was attached to the adapter.

Note:SecureFlexventmustbeattachedtoSecure Flexterminationsonly.DONOTsubstituteSecure Vent terminations or the Secure Vent adapter for Secure Flex components. The collars of Secure Flex terminations and adapters have a different diameter than that used with the Secure Vent pipe. Additionally, Secure Flex components have an extended length center tube for use in attaching the flexible vent.

Image 22
Contents 850,029M REV. G 05/2008 Vented GAS Fireplace Heaters Direct Vent ModelsOTL Report No -F-31-5 Table of Contents SIT Millivolt Honeywell MillivoltMassachusetts And New York City, NY Re- quirements Cold Climate InsulationLocation MassachusettsHorizontal Vent Termination Clearances Manufactured Home RequirementsVertical Vent Termination Clearances Vent Termination Clearances= Clearance to service regulator vent outlet Feet 91cm Canadian Installation US InstallationMeter/regulator assembly Inches 30cmPanel or louvers Minimum Clearances to CombustiblesAppliance and Vent Clearances Adjacent to itFraming Detailed Installation StepsTypical Installation Sequence Routing Gas LineThis center mark see Figure Fireplace specificationsFrom Vent Size Vertical Venting Through the CeilingNatural Fireplace Framing specificationsSchedule Black Iron Pipe Inside Diameter Inches PropaneThese fireplaces must be vented directly to the outside Install the Vent System General InformationCross Section Vertical Termination Systems Roof Vertical Straight InstallationVent Section Length Chart Effective Vent LengthVertical Offset Installation Attach vent components to each otherPitch Vertical Vent FIGURES/TABLESIf the vent system extends more than 5 feet 524 Elbow Only 305 048 610 572 914 096 219 610 305 219 829 914 438Table B Maximum Minimum Feet Meter Ratio V to H ratio is524 610 305 048 219 572 829 914 096 438 Table CMaximum Minimum Feet Meter Table D + H1 Maximum MinimumTypical Horizontal Vent Installation See on Page 12 or onSame manner as any SV4.5 vent component refer to Step E Install Firestop/Spacer at exterior wallSee on Page 9 for Min Feet Meter Horizontal Vent FIGURES/TABLESTable F Maximum 914Horizontal Vent Figures / Tables 524 305 Minimum524 Elbow Only 048 610 572 914Flexible Vent Section Install the Outer Flex PipeAttach Flex Vent to Termination Wiring Optional Forced Air Blower Kit Field WiringSee Figure Connecting Gas Line Schematic Representation OnlyChecking Appliance Opera- tion Control Compartment AccessLouver Panel Instructions Ref SIT and Honeywell Millivolt Appliance CheckoutElectronic Appliance Checkout Install VERMICULITE, VOLCanic STONE, Glowing Embers and Logs Catalog Number H3366 LOG SETShown here 1 through 6 and per the instructions on Model LMDV-4035 Catalog Number H3365Burner Adjustments Flame Appearance and sooting Installing the Glass DoorInstalling Glass Enclosure Panels Air Shutter Adjustment GuidelinesFinishing Requirements Wall Details Burner Air Shutter Adjustment ProcedureHood Installation Drywall Bracket / Spacer12B Cat. No Model Description12C Cat. No Open Top, Chase Top ShroudDescription Listed Secure Flex ComponentsLMDV-3328 & LMDV-3530 Models Only All compressed flex vents can be expanded up to two timesH2013 H2009H2011 H2010SIT Millivolt Gas Valve Adjusting KnobMillivolt Appliances SIT Systems Pilot for SIT Millivolt Gas ValveSeries Pilot Orifice Ignitor AssemblyElectronic Appliances Honeywell Systems 850,029M REV. G 05/2008 West Taft Avenue Orange, CA

LMDV-3530-CNM, LMDV-35 Series, LMDVR-3328-CNE, LMDV-4035-CNE, LMDV-4035-CPM specifications

Lennox Hearth products are renowned for their quality, efficiency, and innovative technologies that optimize the home heating experience. Among the standout offerings in their lineup are the LMDV-3530-CPM, LMDVR-3328-CPM, LMDV-3530-CNE, LMDVT-3328-CPM, and LMDVR-3328-CNM models. Each of these products embodies the brand's commitment to performance and design, making them a popular choice for modern homeowners.

The LMDV-3530-CPM gas fireplace boasts a contemporary aesthetic combined with powerful heating capabilities. It features a clean face design that enhances the viewing experience while maximizing warmth in the room. The unit is equipped with advanced technology that includes multi-speed blowers for efficient air circulation, allowing users to enjoy consistent heat throughout the space. Its variable flame and heat control options ensure that homeowners can customize their ambience and comfort levels according to their preferences.

Similarly, the LMDVR-3328-CPM model is designed for versatility and efficiency. Its modern fireplace insert converts existing masonry fireplaces into high-efficiency heating systems. Featuring a sleek design, this insert incorporates innovative venting technologies that enable it to operate in diverse installation configurations, enhancing both aesthetic appeal and functionality. Homeowners can appreciate the adjustable flame and fan speed settings, which provide tailored heating solutions.

The LMDV-3530-CNE model distinguishes itself through eco-friendly features. It employs advanced combustion technology that reduces emissions without sacrificing heat output. This model stands out as an environmentally responsible option, suitable for conscious consumers who wish to reduce their carbon footprint. Its easy-to-use controls and stylish design make it a favored choice among discerning homeowners.

The LMDVT-3328-CPM continues the trend of performance and versatility. This model combines traditional charm with modern efficiency, featuring a large viewing area that allows for an inviting flame display. The unit’s heat exchanger is designed for maximum heat transfer, ensuring that warmth is efficiently distributed throughout the room.

Lastly, the LMDVR-3328-CNM model is perfect for those seeking an efficient upgrade for their traditional fireplace. With its stunning design and advanced features, including optional remote control and programmable settings, this model takes convenience to new heights.

Overall, Lennox Hearth’s suite of models combines elegance, efficiency, and innovation, ensuring that homeowners can find the perfect heating solution to complement their living spaces. Each product is engineered with state-of-the-art technologies that reflect Lennox’s dedication to quality and customer satisfaction.