4-8. Electrical Service Guide For 230 VAC Model

Input Voltage

Input Amperes At Rated Output

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

Circuit Breaker 1, Time-Delay 2

Normal Operating 3

Min Input Conductor Size In AWG

Max Recommended Input Conductor Length In Feet (Meters)

Min Grounding Conductor Size In AWG

230

20

25

30

14

67

(20)

14

Reference: 1999 National Electrical Code (NEC)

1Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.

2“Time-Delay” fuses are UL class “RK5” .

3 “Normal Operating” (general purpose − no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).

4-9. Installing Wire Spool And Adjusting Hub Tension

Installing 4 in (102 mm) Wire Spool

Installing 8 in (203 mm) Wire Spool

When a slight force is needed to turn spool, tension is set.

Adapter used with

8 in (203 mm)

spool only.

When a slight force is needed to turn spool, tension is set.

Retaining ring used with 8 in (203 mm) spool only.

Tools Needed:

1/2 in

803 012 / 803 013 -B / Ref. 802 971-C

Return To Table Of Contents

OM-925 Page 17

Page 21
Image 21
Hobart Welding Products OM-925 217 694A manual Electrical Service Guide For 230 VAC Model