Trane TCONT802AS32DA, TCONT803AS32DA Adaptive 0530 Adaptive Intelligent Conventional recovery

Page 15

TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION

Table 4. Installer Setup Menu. (Continued)

 

 

 

 

 

 

 

 

 

Factory Setting

 

Other Choices

 

 

Installer

 

 

 

 

 

Select

Setup

 

 

 

 

 

Number

Option

Description

Options

Description

Comments

Adaptive

0530

1

Adaptive Intelligent

0

0—conventional recovery

Intelligent

 

 

Recovery™ control is

 

(system starts recovery at

 

Recovery™

 

 

activated (system

 

programmed time)

 

 

 

 

starts early so setpoint

 

 

 

 

 

 

is reached by start of

 

 

 

 

 

 

program period).

 

 

 

Number of

0540

4

Four periods available

2

Two periods available (Wake

Not shown if

Periods

 

 

(Wake, Leave, Return,

 

and Sleep)

non-programmable is

 

 

 

Sleep)

 

 

selected. 2 or 4

 

 

 

 

 

 

applies to all days of

 

 

 

 

 

 

the week.

Minimum

0580

5

Five minute minimum

0, 2, 3,

Minimum number of minutes

Five minutes

Compressor

 

 

off time for

4

compressor is off between

recommended

Off Time

 

 

compressor.

 

calls for compressor.

 

Heat

0600

90

Highest heating

40 to 89

Temperature range (1°F

Shown in 1/2 °C.

Temperature

 

 

setpoint.

 

increments) of heating

 

Range Stop

 

 

 

 

setpoint.

 

Cool

0610

50

Lowest cooling

51 to 99

Temperature range (1°F

Shown in 1/2 °C.

Temperature

 

 

setpoint.

 

increments) of cooling

 

Range Stop

 

 

 

 

setpoint.

 

Clock Format

0640

12

12-hour clock format

24

24-hour clock format

Extended Fan

0650

0

No extended fan

90

Fan operation is extended 90

Not shown if fan

on time Heat

 

 

operation after call for

 

seconds after call for heat

operation is set to

 

 

 

heat ends.

 

ends.

fossil fuel or in Cool

 

 

 

 

 

 

Only Systems

Extended Fan

0660

0

No extended fan

90

Fan operation is extended 90

Not shown in Heat

on time Cool

 

 

operation after call for

 

seconds after call for cool

Only Systems.

 

 

 

cool ends.

 

ends.

 

Keypad

0670

0

Unlocked keypad

1, 2

1—partially locked keypad

Unlocked—all

Lockout

 

 

 

 

2—fully locked keypad

functions are

 

 

 

 

 

 

available.

 

 

 

 

 

 

Partially locked—only

 

 

 

 

 

 

temperature up and

 

 

 

 

 

 

down keys and ability

 

 

 

 

 

 

to enter and modify

 

 

 

 

 

 

Installer Setup mode

 

 

 

 

 

 

are available. Fully

 

 

 

 

 

 

locked—only ability to

 

 

 

 

 

 

enter and modify

 

 

 

 

 

 

Installer Setup mode

 

 

 

 

 

 

are available.

 

Pub. No. 18-HD25D19-3

15

69-1790—3

Image 15
Contents When Installing this Product ApplicationSelecting Location Disconnect power before wiring Installing WallplatePub. No -HD25D19-3 Heat Pump PM-A Variable Speed AIR Handler Heat Pump Variable M24202 Powering the Comfort Control Vac Common Power RecommendedBattery Power Optional Mounting the Comfort Control Adjusting Real-Time ClockUsing the Comfort Control Setting Calendar and TimeSystem and Fan Settings OperationLED Indication Requires 24 Vac Common Connection Installer Setup Installer Setup Menu Factory Setting Other Choices Cycles per 0240 Heat Stage 1 cycles Deadband 0310 Adaptive 0530 Adaptive Intelligent Conventional recovery Overshoot System Checkout Installer System TestDehumidification Droop Control Advanced FeaturesOutdoor or Indoor Temperature Sensor Special Heat Pump FeaturesTroubleshooting Symptom Possible Cause Action Troubleshooting see TableRegistered Trademark