Trane TCONT802AS32DA, TCONT803AS32DA installation instructions Pub. No -HD25D19-3

Page 3

TCONT802AS32DA TOUCH SCREEN AND TCONT803AS32DA TOUCH SCREEN WITH DEHUMIDIFICATION

 

 

HEAT/COOL

Y2

1

RC

 

 

R

 

 

W1

W2

 

Y

S1

 

G

S2

 

B

 

T

 

 

2

 

 

 

HEAT/COOL

Y2

1

RC

 

 

R

 

 

W1

W2

 

Y

S1

 

G

S2

 

B

2

T

 

 

 

R Y G W1 W2 W3 B/C

INDOOR

OUTDOOR

AIR HANDLER

R

BK

O

YLO

Y

G

W1

W2

B/C

INDOOR

OUTDOOR

VARIABLE SPEED

TWO-STAGE

FURNACE/VARIABLE SPEED AIR HANDLER

Y ODT B

 

 

 

 

 

 

 

 

TO POWER SUPPLY

(3 PH

PER LOCAL CODES

ONLY)

1 FACTORY INSTALLED JUMPER.

COOLING UNIT O.D. SECTION (SINGLE STAGE)

Y1 Y2

B

COOLING UNIT

O.D. SECTION

 

 

(TWO STAGE)

TO POWER SUPPLY

(3 PH

 

PER LOCAL CODES

ONLY)

 

 

 

1 FACTORY INSTALLED JUMPER.

OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE

2 ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE

FROM THE THERMOSTAT CABLE.

M22637

 

2 OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE

ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE

FROM THE THERMOSTAT CABLE.

M22640

 

Fig. 5. Typical hookup of single-stage heat and cool

system with single transformer (1H/1C).

 

HEAT/COOL

Y2

RC

 

R

 

W1

W2

Y

S1

G

S2

B

 

T

 

1

Fig. 7. Typical hookup of two-stage indoor and two-stage cooling unit in a single transformer system (2H/2C or 2H/1C or 1H/2C).

 

 

HEAT/COOL

Y2

1

RC

 

 

R

 

 

W1

W2

 

Y

S1

 

G

S2

 

B

2

T

 

 

 

3

 

 

R Y G T T W B/C

OIL BURNER PRIMARY

INDOOR

OUTDOOR

YB

 

 

 

 

 

 

 

 

TO POWER SUPPLY

(3 PH

PER LOCAL CODES

ONLY)

OIL

FURNACE

COOLING UNIT O.D. SECTION (SINGLE STAGE)

R

 

BK

 

O

YLO

 

Y

 

G

 

W1

 

W2

B/C

VARIABLE SPEED

 

 

 

 

 

 

 

TWO STAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FURNACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16 SEER

 

 

Y2

 

Y1

 

 

 

 

 

B

 

 

 

COOLING UNIT

 

 

 

 

 

 

 

 

 

 

 

O.D. SECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(TWO STEP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO POWER SUPPLY

(3 PH

 

PER LOCAL CODES

ONLY)

 

 

1 FACTORY INSTALLED JUMPER.

1 OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE

FROM THE THERMOSTAT CABLE.

M22638

Fig. 6. Typical hookup of single-stage heat and cool

system with two transformers (1H/1C).

2OPTIONAL OUTDOOR OR INDOOR REMOTE SENSOR. AVAILABLE ON SELECT MODELS. WIRES MUST HAVE A CABLE SEPARATE FROM THE THERMOSTAT CABLE.

3 THE INSTALLER MUST JUMPER AT THE LVTB “R” TO “O”. M24231

Fig. 8. Typical hookup of two-stage indoor and two-step scroll cooling unit in a single transformer system (2H/2C or 2H/1C or 1H/2C).

 

Pub. No. 18-HD25D19-3

3

69-1790—3

Image 3
Contents When Installing this Product ApplicationSelecting Location Disconnect power before wiring Installing WallplatePub. No -HD25D19-3 Heat Pump PM-A Variable Speed AIR Handler Heat Pump Variable M24202 Powering the Comfort Control Vac Common Power RecommendedBattery Power Optional Mounting the Comfort Control Adjusting Real-Time ClockUsing the Comfort Control Setting Calendar and TimeSystem and Fan Settings OperationLED Indication Requires 24 Vac Common Connection Installer Setup Installer Setup Menu Factory Setting Other Choices Cycles per 0240 Heat Stage 1 cycles Deadband 0310 Adaptive 0530 Adaptive Intelligent Conventional recovery Overshoot System Checkout Installer System TestDehumidification Droop Control Advanced FeaturesOutdoor or Indoor Temperature Sensor Special Heat Pump FeaturesTroubleshooting Symptom Possible Cause Action Troubleshooting see TableRegistered Trademark