Trane Trane, VAV-SVN01E-EN manual Chart 5 -VPxF 04SQ ECM CFMTable

Page 35

Unit

Setup

Chart 5 –VPxF 04SQ ECM CFMTable

VPxF 04SQ

Motor Min CFM: 220

Motor Max CFM: 1510

 

 

%

TENS

UNITS

CFM

L/sec

Setting

Switch

Switch

220

104

1

0

1

233

110

2

0

2

246

116

3

0

3

259

122

4

0

4

272

128

5

0

5

285

135

6

0

6

298

141

7

0

7

311

147

8

0

8

324

153

9

0

9

337

159

10

1

0

350

165

11

1

1

363

171

12

1

2

376

178

13

1

3

389

184

14

1

4

402

190

15

1

5

415

196

16

1

6

429

202

17

1

7

442

208

18

1

8

455

215

19

1

9

468

221

20

2

0

481

227

21

2

1

494

233

22

2

2

507

239

23

2

3

520

245

24

2

4

533

251

25

2

5

546

258

26

2

6

559

264

27

2

7

572

270

28

2

8

585

276

29

2

9

598

282

30

3

0

611

288

31

3

1

624

294

32

3

2

637

301

33

3

3

650

307

34

3

4

663

313

35

3

5

676

319

36

3

6

689

325

37

3

7

702

331

38

3

8

715

338

39

3

9

728

344

40

4

0

741

350

41

4

1

754

356

42

4

2

767

362

43

4

3

780

368

44

4

4

793

374

45

4

5

806

381

46

4

6

819

387

47

4

7

832

393

48

4

8

845

399

49

4

9

859

405

50

5

0

 

 

%

TENS

UNITS

CFM

L/sec

Setting

Switch

Switch

872

411

51

5

1

885

417

52

5

2

898

424

53

5

3

911

430

54

5

4

924

436

55

5

5

937

442

56

5

6

950

448

57

5

7

963

454

58

5

8

976

461

59

5

9

989

467

60

6

0

1002

473

61

6

1

1015

479

62

6

2

1028

485

63

6

3

1041

491

64

6

4

1054

497

65

6

5

1067

504

66

6

6

1080

510

67

6

7

1093

516

68

6

8

1106

522

69

6

9

1119

528

70

7

0

1132

534

71

7

1

1145

540

72

7

2

1158

547

73

7

3

1171

553

74

7

4

1184

559

75

7

5

1197

565

76

7

6

1210

571

77

7

7

1223

577

78

7

8

1236

584

79

7

9

1249

590

80

8

0

1262

596

81

8

1

1275

602

82

8

2

1288

608

83

8

3

1302

614

84

8

4

1315

620

85

8

5

1328

627

86

8

6

1341

633

87

8

7

1354

639

88

8

8

1367

645

89

8

9

1380

651

90

9

0

1393

657

91

9

1

1406

663

92

9

2

1419

670

93

9

3

1432

676

94

9

4

1445

682

95

9

5

1458

688

96

9

6

1471

694

97

9

7

1484

700

98

9

8

1497

706

99

9

9

1510

713

100

0

0

VAV-SVN01E-EN

35

Image 35
Contents June Installation Operator MaintenanceAmerican Standard All rights reserved Contents Fiberglass Wool Single-Duct Units Vcef Door Interlocking Power Disconnect Digit 9-Not Used Dual-Duct UnitsDigit 1, 2, 3-UnitType Digit 7, 8-Secondary AirValveVpef Door Interlocking Power Disconnect Fan-Powered Parallel UnitsDigit 32-Airflow Switch Service Model Number DescriptionFan Note See fan curves for specific airflows Fan-Powered Series UnitsVsef Door Interlocking Power Disconnect Digit 27, 28, 29-Electric Heat Kilowatts Lpef Door Interlocking Power Disconnect Fan-Powered Low-Height Parallel UnitsDigit 27, 28, 29-Electric HeatVoltage Lsef Door Interlocking Power Disconnect Fan-Powered Low-Height Series UnitsDigit 32-Air Flow Switch Receiving and Handling Literature ContentsGeneral Information Dual-Duct Units Unit InformationSingle-Duct Units Typical Fan-Powered Units Fan-Powered and Fan-Powered Low-Height UnitsDual-Duct Unit InstallationSingle-Duct Parallel Hanger Bracket Locations Sizes Fan-Powered Standard and Low- HeightSeries Hanger Bracket Locations Low-Height Parallel 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Parallel10SQ Low-Height Series 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Series 10SQ w/ Hot Water or Electric Heat Attenuator Installation-Parallel Units Attenuator Installation-Series Units Attenuator Installation-Low-Height Parallel Units Attenuator Installation-Low-Height Series Units Parallel Fan-Powered Units Chart 1 UnitWeightsLow-Height Parallel Units Series Fan-Powered UnitVscf w Vsef wEquipment Damage Maximum PSC Fan MotorAmperage FLA Unit SetupChart 2 Flow Sensor Delta P vs.Airflow Delivery Chart 3- Fan Motor AmperageElectrically Commutated Motor ECM HazardousVoltageMotor Min CFM Motor Max CFM Chart 4 -VPxF 03SQ ECM CFMTableVPxF 03SQ VPxF 04SQ Chart 5 -VPxF 04SQ ECM CFMTableVPxF 05SQ Chart 6 -VPxF 05SQ ECM CFMTableVPxF 06SQ Chart 7 -VPxF 06SQ ECM CFMTableVSxF 03SQ Chart 8 -VSxF 03SQ ECM CFMTableVSxF 04SQ Chart 9-VSxF 04SQ ECM CFMTableVSxF 05SQ Chart 10-VSxF 05SQ ECM CFMTableVSxF 06SQ Chart 11-VSxF 06SQ ECM CFMTableLPxF 08SQ Chart 12- LPxF 08SQ ECM CFMTableLPxF 09SQ Chart 13- LPxF 09SQ ECM CFMTableLSxF 08SQ Chart 14- LSxF 08SQ ECM CFMTableLSxF 09SQ Chart 15- LSxF 09SQ ECM CFMTableLSxF 10SQ Chart 15- LSxF 10SQ ECM CFMTableSingle-Duct Units Electronic or DDC/UCM Wiring DiagramsSingle-Duct Units Pneumatic Controls Fan-Powered Units Electronic or DDC/UCM Fan-Powered Units Pneumatic Controls Fan-Powered Control Boxes Fan-Powered Units with ECM Fan-Powered Low-Height Units Fan-Powered Low-Height Units with ECM Rotating Components MaintenanceConcealed Spline Ceiling Installation of DiffusersGeneral Bar CeilingDate Tag Serial # Service Notes Maintenance/ Service LogMaintenance/ Service Log VAV-SVN01E-EN Trane

VAV-SVN01E-EN, Trane specifications

The Trane VAV-SVN01E-EN is an advanced variable air volume (VAV) system designed to optimize indoor air quality and energy efficiency in commercial buildings. This system is part of Trane’s commitment to offering reliable, innovative HVAC solutions that meet the demands of modern architectural designs and energy standards.

One of the main features of the VAV-SVN01E-EN is its ability to control air flow based on occupancy and environmental conditions. This ensures that energy is used efficiently, as airflow can be adjusted to match real-time needs, rather than operating at a constant rate. The integration of intelligent sensors allows the system to adapt dynamically, leading to both reduced energy consumption and improved comfort for building occupants.

The technology behind the VAV-SVN01E-EN includes advanced digital controls and integration capabilities. These controls enable the system to communicate seamlessly with building management systems (BMS), allowing for centralized monitoring and management. This interconnected approach not only enhances operational efficiency but also enables predictive maintenance, helping facility managers identify and address potential issues before they become problematic.

Energy efficiency is further enhanced through the use of VAV technology, which reduces the amount of conditioned air delivered when spaces are unoccupied or when less cooling or heating is required. This tailored approach contributes to lower energy costs and supports sustainability initiatives by decreasing the overall carbon footprint of the building.

Key characteristics of the Trane VAV-SVN01E-EN include its compact design, which facilitates easy installation in existing spaces without significant modifications. The unit is also designed for low sound levels, ensuring that it operates quietly, contributing to a more pleasant indoor environment. Moreover, the VAV system is engineered to be reliable and durable, with rigorous testing and high-quality components ensuring long-term performance.

In summary, the Trane VAV-SVN01E-EN stands out in the field of HVAC solutions, bringing together advanced technology, energy efficiency, and user comfort. Its features are tailored for modern building requirements, making it a preferred choice for facility managers aiming to enhance indoor air quality while reducing operational costs.