Trane Trane, VAV-SVN01E-EN manual Chart 9-VSxF 04SQ ECM CFMTable

Page 39

Unit

Setup

Chart 9–VSxF 04SQ ECM CFMTable

VSxF 04SQ

Motor Min CFM: 275

Motor Max CFM: 1500

 

%

TENS

UNITS

 

CFM

L/sec

Setting

Switch

Switch

275

130

1

0

1

288

136

2

0

2

300

142

3

0

3

312

147

4

0

4

325

153

5

0

5

337

159

6

0

6

350

165

7

0

7

362

171

8

0

8

374

177

9

0

9

387

183

10

1

0

399

188

11

1

1

411

194

12

1

2

424

200

13

1

3

436

206

14

1

4

449

212

15

1

5

461

218

16

1

6

473

223

17

1

7

486

229

18

1

8

498

235

19

1

9

510

241

20

2

0

523

247

21

2

1

535

253

22

2

2

548

258

23

2

3

560

264

24

2

4

572

270

25

2

5

585

276

26

2

6

597

282

27

2

7

609

288

28

2

8

622

293

29

2

9

634

299

30

3

0

646

305

31

3

1

659

311

32

3

2

671

317

33

3

3

684

323

34

3

4

696

328

35

3

5

708

334

36

3

6

721

340

37

3

7

733

346

38

3

8

745

352

39

3

9

758

358

40

4

0

770

363

41

4

1

783

369

42

4

2

795

375

43

4

3

807

381

44

4

4

820

387

45

4

5

832

393

46

4

6

844

399

47

4

7

857

404

48

4

8

869

410

49

4

9

882

416

50

5

0

 

 

%

TENS

UNITS

CFM

L/sec

Setting

Switch

Switch

894

422

51

5

1

906

428

52

5

2

919

434

53

5

3

931

439

54

5

4

943

445

55

5

5

956

451

56

5

6

968

457

57

5

7

980

463

58

5

8

993

469

59

5

9

1005

474

60

6

0

1018

480

61

6

1

1030

486

62

6

2

1042

492

63

6

3

1055

498

64

6

4

1067

504

65

6

5

1079

509

66

6

6

1092

515

67

6

7

1104

521

68

6

8

1117

527

69

6

9

1129

533

70

7

0

1141

539

71

7

1

1154

544

72

7

2

1166

550

73

7

3

1178

556

74

7

4

1191

562

75

7

5

1203

568

76

7

6

1215

574

77

7

7

1228

579

78

7

8

1240

585

79

7

9

1253

591

80

8

0

1265

597

81

8

1

1277

603

82

8

2

1290

609

83

8

3

1302

615

84

8

4

1314

620

85

8

5

1327

626

86

8

6

1339

632

87

8

7

1352

638

88

8

8

1364

644

89

8

9

1376

650

90

9

0

1389

655

91

9

1

1401

661

92

9

2

1413

667

93

9

3

1426

673

94

9

4

1438

679

95

9

5

1451

685

96

9

6

1463

690

97

9

7

1475

696

98

9

8

1488

702

99

9

9

1500

708

100

0

0

VAV-SVN01E-EN

39

Image 39
Contents June Installation Operator MaintenanceAmerican Standard All rights reserved Contents Fiberglass Wool Single-Duct Units Vcef Door Interlocking Power Disconnect Digit 9-Not Used Dual-Duct UnitsDigit 1, 2, 3-UnitType Digit 7, 8-Secondary AirValveVpef Door Interlocking Power Disconnect Fan-Powered Parallel UnitsDigit 32-Airflow Switch Service Model Number DescriptionFan-Powered Series Units Vsef Door Interlocking Power DisconnectFan Note See fan curves for specific airflows Digit 27, 28, 29-Electric Heat Kilowatts Lpef Door Interlocking Power Disconnect Fan-Powered Low-Height Parallel UnitsDigit 27, 28, 29-Electric HeatVoltage Lsef Door Interlocking Power Disconnect Fan-Powered Low-Height Series UnitsDigit 32-Air Flow Switch Literature Contents General InformationReceiving and Handling Unit Information Single-Duct UnitsDual-Duct Units Typical Fan-Powered Units Fan-Powered and Fan-Powered Low-Height UnitsUnit Installation Single-DuctDual-Duct Parallel Hanger Bracket Locations Sizes Fan-Powered Standard and Low- HeightSeries Hanger Bracket Locations Low-Height Parallel 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Parallel10SQ Low-Height Series 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Series 10SQ w/ Hot Water or Electric Heat Attenuator Installation-Parallel Units Attenuator Installation-Series Units Attenuator Installation-Low-Height Parallel Units Attenuator Installation-Low-Height Series Units Parallel Fan-Powered Units Chart 1 UnitWeightsLow-Height Parallel Units Series Fan-Powered UnitVscf w Vsef wEquipment Damage Maximum PSC Fan MotorAmperage FLA Unit SetupChart 2 Flow Sensor Delta P vs.Airflow Delivery Chart 3- Fan Motor AmperageElectrically Commutated Motor ECM HazardousVoltageChart 4 -VPxF 03SQ ECM CFMTable VPxF 03SQMotor Min CFM Motor Max CFM VPxF 04SQ Chart 5 -VPxF 04SQ ECM CFMTableVPxF 05SQ Chart 6 -VPxF 05SQ ECM CFMTableVPxF 06SQ Chart 7 -VPxF 06SQ ECM CFMTableVSxF 03SQ Chart 8 -VSxF 03SQ ECM CFMTableVSxF 04SQ Chart 9-VSxF 04SQ ECM CFMTableVSxF 05SQ Chart 10-VSxF 05SQ ECM CFMTableVSxF 06SQ Chart 11-VSxF 06SQ ECM CFMTableLPxF 08SQ Chart 12- LPxF 08SQ ECM CFMTableLPxF 09SQ Chart 13- LPxF 09SQ ECM CFMTableLSxF 08SQ Chart 14- LSxF 08SQ ECM CFMTableLSxF 09SQ Chart 15- LSxF 09SQ ECM CFMTableLSxF 10SQ Chart 15- LSxF 10SQ ECM CFMTableSingle-Duct Units Electronic or DDC/UCM Wiring DiagramsSingle-Duct Units Pneumatic Controls Fan-Powered Units Electronic or DDC/UCM Fan-Powered Units Pneumatic Controls Fan-Powered Control Boxes Fan-Powered Units with ECM Fan-Powered Low-Height Units Fan-Powered Low-Height Units with ECM Rotating Components MaintenanceConcealed Spline Ceiling Installation of DiffusersGeneral Bar CeilingDate Tag Serial # Service Notes Maintenance/ Service LogMaintenance/ Service Log VAV-SVN01E-EN Trane

VAV-SVN01E-EN, Trane specifications

The Trane VAV-SVN01E-EN is an advanced variable air volume (VAV) system designed to optimize indoor air quality and energy efficiency in commercial buildings. This system is part of Trane’s commitment to offering reliable, innovative HVAC solutions that meet the demands of modern architectural designs and energy standards.

One of the main features of the VAV-SVN01E-EN is its ability to control air flow based on occupancy and environmental conditions. This ensures that energy is used efficiently, as airflow can be adjusted to match real-time needs, rather than operating at a constant rate. The integration of intelligent sensors allows the system to adapt dynamically, leading to both reduced energy consumption and improved comfort for building occupants.

The technology behind the VAV-SVN01E-EN includes advanced digital controls and integration capabilities. These controls enable the system to communicate seamlessly with building management systems (BMS), allowing for centralized monitoring and management. This interconnected approach not only enhances operational efficiency but also enables predictive maintenance, helping facility managers identify and address potential issues before they become problematic.

Energy efficiency is further enhanced through the use of VAV technology, which reduces the amount of conditioned air delivered when spaces are unoccupied or when less cooling or heating is required. This tailored approach contributes to lower energy costs and supports sustainability initiatives by decreasing the overall carbon footprint of the building.

Key characteristics of the Trane VAV-SVN01E-EN include its compact design, which facilitates easy installation in existing spaces without significant modifications. The unit is also designed for low sound levels, ensuring that it operates quietly, contributing to a more pleasant indoor environment. Moreover, the VAV system is engineered to be reliable and durable, with rigorous testing and high-quality components ensuring long-term performance.

In summary, the Trane VAV-SVN01E-EN stands out in the field of HVAC solutions, bringing together advanced technology, energy efficiency, and user comfort. Its features are tailored for modern building requirements, making it a preferred choice for facility managers aiming to enhance indoor air quality while reducing operational costs.