Trane Trane, VAV-SVN01E-EN manual Contents

Page 3

Contents

Service Model Number Description

4 – 14

General Information

15

Literature Contents

 

Receiving and Handling

 

Warnings and Cautions Explanations

 

Unit Information

16 – 17

Single-Duct Units

 

Dual-Duct Units

 

Fan-Powered and Low-Height Units

 

Unit Installation

18 – 31

Hanging Bracket Locations

 

Unit Weights

 

Water Coil Connections

 

Unit Accessibility

 

Clearances

 

Actuator Mounting

 

Unit Setup

32 – 46

Flow Sensor P vs. Airflow Delivery

 

Maximum Fan Motor Amperage

 

(SCR) Motor Speed Control Adjustment Procedure

 

Electrically Commutated Motor (ECM)

 

ECM CFMTables

 

Wiring Diagrams

47 – 54

Maintenance

55

Motors

 

Fan Wheel

 

Filter

 

Water Coil

 

Fan Motor Replacement

 

Installation of Diffusers

56

T-Bar Ceiling

 

Concealed Spline Ceiling

 

Drywall/Plaster Ceiling

 

VAV-SVN01E-EN

3

Image 3
Contents June Installation Operator MaintenanceAmerican Standard All rights reserved Contents Fiberglass Wool Single-Duct Units Vcef Door Interlocking Power Disconnect Digit 9-Not Used Dual-Duct UnitsDigit 1, 2, 3-UnitType Digit 7, 8-Secondary AirValveVpef Door Interlocking Power Disconnect Fan-Powered Parallel UnitsDigit 32-Airflow Switch Service Model Number DescriptionFan-Powered Series Units Vsef Door Interlocking Power DisconnectFan Note See fan curves for specific airflows Digit 27, 28, 29-Electric Heat Kilowatts Lpef Door Interlocking Power Disconnect Fan-Powered Low-Height Parallel UnitsDigit 27, 28, 29-Electric HeatVoltage Lsef Door Interlocking Power Disconnect Fan-Powered Low-Height Series UnitsDigit 32-Air Flow Switch Literature Contents General InformationReceiving and Handling Unit Information Single-Duct UnitsDual-Duct Units Typical Fan-Powered Units Fan-Powered and Fan-Powered Low-Height UnitsUnit Installation Single-DuctDual-Duct Parallel Hanger Bracket Locations Sizes Fan-Powered Standard and Low- HeightSeries Hanger Bracket Locations Low-Height Parallel 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Parallel10SQ Low-Height Series 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Series 10SQ w/ Hot Water or Electric Heat Attenuator Installation-Parallel Units Attenuator Installation-Series Units Attenuator Installation-Low-Height Parallel Units Attenuator Installation-Low-Height Series Units Parallel Fan-Powered Units Chart 1 UnitWeightsLow-Height Parallel Units Series Fan-Powered UnitVscf w Vsef wEquipment Damage Maximum PSC Fan MotorAmperage FLA Unit SetupChart 2 Flow Sensor Delta P vs.Airflow Delivery Chart 3- Fan Motor AmperageElectrically Commutated Motor ECM HazardousVoltageChart 4 -VPxF 03SQ ECM CFMTable VPxF 03SQMotor Min CFM Motor Max CFM VPxF 04SQ Chart 5 -VPxF 04SQ ECM CFMTableVPxF 05SQ Chart 6 -VPxF 05SQ ECM CFMTableVPxF 06SQ Chart 7 -VPxF 06SQ ECM CFMTableVSxF 03SQ Chart 8 -VSxF 03SQ ECM CFMTableVSxF 04SQ Chart 9-VSxF 04SQ ECM CFMTableVSxF 05SQ Chart 10-VSxF 05SQ ECM CFMTableVSxF 06SQ Chart 11-VSxF 06SQ ECM CFMTableLPxF 08SQ Chart 12- LPxF 08SQ ECM CFMTableLPxF 09SQ Chart 13- LPxF 09SQ ECM CFMTableLSxF 08SQ Chart 14- LSxF 08SQ ECM CFMTableLSxF 09SQ Chart 15- LSxF 09SQ ECM CFMTableLSxF 10SQ Chart 15- LSxF 10SQ ECM CFMTableSingle-Duct Units Electronic or DDC/UCM Wiring DiagramsSingle-Duct Units Pneumatic Controls Fan-Powered Units Electronic or DDC/UCM Fan-Powered Units Pneumatic Controls Fan-Powered Control Boxes Fan-Powered Units with ECM Fan-Powered Low-Height Units Fan-Powered Low-Height Units with ECM Rotating Components MaintenanceConcealed Spline Ceiling Installation of DiffusersGeneral Bar CeilingDate Tag Serial # Service Notes Maintenance/ Service LogMaintenance/ Service Log VAV-SVN01E-EN Trane

VAV-SVN01E-EN, Trane specifications

The Trane VAV-SVN01E-EN is an advanced variable air volume (VAV) system designed to optimize indoor air quality and energy efficiency in commercial buildings. This system is part of Trane’s commitment to offering reliable, innovative HVAC solutions that meet the demands of modern architectural designs and energy standards.

One of the main features of the VAV-SVN01E-EN is its ability to control air flow based on occupancy and environmental conditions. This ensures that energy is used efficiently, as airflow can be adjusted to match real-time needs, rather than operating at a constant rate. The integration of intelligent sensors allows the system to adapt dynamically, leading to both reduced energy consumption and improved comfort for building occupants.

The technology behind the VAV-SVN01E-EN includes advanced digital controls and integration capabilities. These controls enable the system to communicate seamlessly with building management systems (BMS), allowing for centralized monitoring and management. This interconnected approach not only enhances operational efficiency but also enables predictive maintenance, helping facility managers identify and address potential issues before they become problematic.

Energy efficiency is further enhanced through the use of VAV technology, which reduces the amount of conditioned air delivered when spaces are unoccupied or when less cooling or heating is required. This tailored approach contributes to lower energy costs and supports sustainability initiatives by decreasing the overall carbon footprint of the building.

Key characteristics of the Trane VAV-SVN01E-EN include its compact design, which facilitates easy installation in existing spaces without significant modifications. The unit is also designed for low sound levels, ensuring that it operates quietly, contributing to a more pleasant indoor environment. Moreover, the VAV system is engineered to be reliable and durable, with rigorous testing and high-quality components ensuring long-term performance.

In summary, the Trane VAV-SVN01E-EN stands out in the field of HVAC solutions, bringing together advanced technology, energy efficiency, and user comfort. Its features are tailored for modern building requirements, making it a preferred choice for facility managers aiming to enhance indoor air quality while reducing operational costs.