Trane VAV-SVN01E-EN, Trane manual Chart 14- LSxF 08SQ ECM CFMTable

Page 44

Unit

Setup

Chart 14– LSxF 08SQ ECM CFMTable

LSxF 08SQ

Motor Min CFM: 100

Motor Max CFM: 460

 

 

%

TENS

UNITS

CFM

L/sec

Setting

Switch

Switch

100

47

1

0

1

103

49

2

0

2

107

50

3

0

3

111

52

4

0

4

114

54

5

0

5

118

56

6

0

6

121

57

7

0

7

125

59

8

0

8

129

61

9

0

9

132

62

10

1

0

136

64

11

1

1

140

66

12

1

2

143

68

13

1

3

147

69

14

1

4

151

71

15

1

5

154

73

16

1

6

158

75

17

1

7

162

76

18

1

8

165

78

19

1

9

169

80

20

2

0

172

81

21

2

1

176

83

22

2

2

180

85

23

2

3

183

87

24

2

4

187

88

25

2

5

191

90

26

2

6

194

92

27

2

7

198

93

28

2

8

202

95

29

2

9

205

97

30

3

0

209

99

31

3

1

212

100

32

3

2

216

102

33

3

3

220

104

34

3

4

223

105

35

3

5

227

107

36

3

6

231

109

37

3

7

234

111

38

3

8

238

112

39

3

9

242

114

40

4

0

245

116

41

4

1

249

117

42

4

2

253

119

43

4

3

256

121

44

4

4

260

123

45

4

5

263

124

46

4

6

267

126

47

4

7

271

128

48

4

8

274

129

49

4

9

278

131

50

5

0

 

 

%

TENS

UNITS

CFM

L/sec

Settings

Switch

Switch

282

133

51

5

1

285

135

52

5

2

289

136

53

5

3

293

138

54

5

4

296

140

55

5

5

300

142

56

5

6

303

143

57

5

7

307

145

58

5

8

311

147

59

5

9

314

148

60

6

0

318

150

61

6

1

322

152

62

6

2

325

154

63

6

3

329

155

64

6

4

333

157

65

6

5

336

159

66

6

6

340

160

67

6

7

344

162

68

6

8

347

164

69

6

9

351

166

70

7

0

354

167

71

7

1

358

169

72

7

2

362

171

73

7

3

365

172

74

7

4

369

174

75

7

5

373

176

76

7

6

376

178

77

7

7

380

179

78

7

8

384

181

79

7

9

387

183

80

8

0

391

184

81

8

1

394

186

82

8

2

398

188

83

8

3

402

190

84

8

4

405

191

85

8

5

409

193

86

8

6

413

195

87

8

7

416

196

88

8

8

420

198

89

8

9

424

200

90

9

0

427

202

91

9

1

431

203

92

9

2

435

205

93

9

3

438

207

94

9

4

442

209

95

9

5

445

210

96

9

6

449

212

97

9

7

453

214

98

9

8

456

215

99

9

9

460

217

100

0

0

44

VAV-SVN01E-EN

Image 44
Contents Installation Operator Maintenance JuneAmerican Standard All rights reserved Contents Fiberglass Wool Single-Duct Units Vcef Door Interlocking Power Disconnect Dual-Duct Units Digit 1, 2, 3-UnitTypeDigit 7, 8-Secondary AirValve Digit 9-Not UsedFan-Powered Parallel Units Vpef Door Interlocking Power DisconnectService Model Number Description Digit 32-Airflow SwitchFan Note See fan curves for specific airflows Fan-Powered Series UnitsVsef Door Interlocking Power Disconnect Digit 27, 28, 29-Electric Heat Kilowatts Fan-Powered Low-Height Parallel Units Lpef Door Interlocking Power DisconnectDigit 27, 28, 29-Electric HeatVoltage Fan-Powered Low-Height Series Units Lsef Door Interlocking Power DisconnectDigit 32-Air Flow Switch Receiving and Handling Literature ContentsGeneral Information Dual-Duct Units Unit InformationSingle-Duct Units Fan-Powered and Fan-Powered Low-Height Units Typical Fan-Powered UnitsDual-Duct Unit InstallationSingle-Duct Fan-Powered Standard and Low- Height Parallel Hanger Bracket Locations SizesSeries Hanger Bracket Locations Low-Height Parallel 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Parallel10SQ Low-Height Series 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Series 10SQ w/ Hot Water or Electric Heat Attenuator Installation-Parallel Units Attenuator Installation-Series Units Attenuator Installation-Low-Height Parallel Units Attenuator Installation-Low-Height Series Units Chart 1 UnitWeights Parallel Fan-Powered UnitsSeries Fan-Powered Unit Vscf wVsef w Low-Height Parallel UnitsEquipment Damage Unit Setup Chart 2 Flow Sensor Delta P vs.Airflow DeliveryChart 3- Fan Motor Amperage Maximum PSC Fan MotorAmperage FLAHazardousVoltage Electrically Commutated Motor ECMMotor Min CFM Motor Max CFM Chart 4 -VPxF 03SQ ECM CFMTableVPxF 03SQ Chart 5 -VPxF 04SQ ECM CFMTable VPxF 04SQChart 6 -VPxF 05SQ ECM CFMTable VPxF 05SQChart 7 -VPxF 06SQ ECM CFMTable VPxF 06SQChart 8 -VSxF 03SQ ECM CFMTable VSxF 03SQChart 9-VSxF 04SQ ECM CFMTable VSxF 04SQChart 10-VSxF 05SQ ECM CFMTable VSxF 05SQChart 11-VSxF 06SQ ECM CFMTable VSxF 06SQChart 12- LPxF 08SQ ECM CFMTable LPxF 08SQChart 13- LPxF 09SQ ECM CFMTable LPxF 09SQChart 14- LSxF 08SQ ECM CFMTable LSxF 08SQChart 15- LSxF 09SQ ECM CFMTable LSxF 09SQChart 15- LSxF 10SQ ECM CFMTable LSxF 10SQWiring Diagrams Single-Duct Units Electronic or DDC/UCMSingle-Duct Units Pneumatic Controls Fan-Powered Units Electronic or DDC/UCM Fan-Powered Units Pneumatic Controls Fan-Powered Control Boxes Fan-Powered Units with ECM Fan-Powered Low-Height Units Fan-Powered Low-Height Units with ECM Maintenance Rotating ComponentsInstallation of Diffusers GeneralBar Ceiling Concealed Spline CeilingMaintenance/ Service Log Date Tag Serial # Service NotesMaintenance/ Service Log VAV-SVN01E-EN Trane

VAV-SVN01E-EN, Trane specifications

The Trane VAV-SVN01E-EN is an advanced variable air volume (VAV) system designed to optimize indoor air quality and energy efficiency in commercial buildings. This system is part of Trane’s commitment to offering reliable, innovative HVAC solutions that meet the demands of modern architectural designs and energy standards.

One of the main features of the VAV-SVN01E-EN is its ability to control air flow based on occupancy and environmental conditions. This ensures that energy is used efficiently, as airflow can be adjusted to match real-time needs, rather than operating at a constant rate. The integration of intelligent sensors allows the system to adapt dynamically, leading to both reduced energy consumption and improved comfort for building occupants.

The technology behind the VAV-SVN01E-EN includes advanced digital controls and integration capabilities. These controls enable the system to communicate seamlessly with building management systems (BMS), allowing for centralized monitoring and management. This interconnected approach not only enhances operational efficiency but also enables predictive maintenance, helping facility managers identify and address potential issues before they become problematic.

Energy efficiency is further enhanced through the use of VAV technology, which reduces the amount of conditioned air delivered when spaces are unoccupied or when less cooling or heating is required. This tailored approach contributes to lower energy costs and supports sustainability initiatives by decreasing the overall carbon footprint of the building.

Key characteristics of the Trane VAV-SVN01E-EN include its compact design, which facilitates easy installation in existing spaces without significant modifications. The unit is also designed for low sound levels, ensuring that it operates quietly, contributing to a more pleasant indoor environment. Moreover, the VAV system is engineered to be reliable and durable, with rigorous testing and high-quality components ensuring long-term performance.

In summary, the Trane VAV-SVN01E-EN stands out in the field of HVAC solutions, bringing together advanced technology, energy efficiency, and user comfort. Its features are tailored for modern building requirements, making it a preferred choice for facility managers aiming to enhance indoor air quality while reducing operational costs.