Trane VAV-SVN01E-EN, Trane manual Chart 4 -VPxF 03SQ ECM CFMTable, Motor Min CFM Motor Max CFM

Page 34

Unit

Setup

Chart 4 –VPxF 03SQ ECM CFMTable

VPxF 03SQ

Motor Min CFM: 160

Motor Max CFM: 1085

 

 

%

TENS

UNITS

CFM

L/sec

Setting

Switch

Switch

160

76

1

0

1

170

80

2

0

2

179

84

3

0

3

188

89

4

0

4

198

93

5

0

5

207

98

6

0

6

216

102

7

0

7

226

107

8

0

8

235

111

9

0

9

244

115

10

1

0

254

120

11

1

1

263

124

12

1

2

272

129

13

1

3

282

133

14

1

4

291

137

15

1

5

300

142

16

1

6

310

146

17

1

7

319

151

18

1

8

328

155

19

1

9

338

159

20

2

0

347

164

21

2

1

356

168

22

2

2

366

173

23

2

3

375

177

24

2

4

385

181

25

2

5

394

186

26

2

6

403

190

27

2

7

413

195

28

2

8

422

199

29

2

9

431

204

30

3

0

441

208

31

3

1

450

212

32

3

2

459

217

33

3

3

469

221

34

3

4

478

226

35

3

5

487

230

36

3

6

497

234

37

3

7

506

239

38

3

8

515

243

39

3

9

525

248

40

4

0

534

252

41

4

1

543

256

42

4

2

553

261

43

4

3

562

265

44

4

4

571

270

45

4

5

581

274

46

4

6

590

278

47

4

7

599

283

48

4

8

609

287

49

4

9

618

292

50

5

0

 

%

TENS

UNITS

 

CFM

L/sec

Setting

Switch

Switch

627

296

51

5

1

637

300

52

5

2

646

305

53

5

3

655

309

54

5

4

665

314

55

5

5

674

318

56

5

6

683

323

57

5

7

693

327

58

5

8

702

331

59

5

9

711

336

60

6

0

721

340

61

6

1

730

345

62

6

2

739

349

63

6

3

749

353

64

6

4

758

358

65

6

5

767

362

66

6

6

777

367

67

6

7

786

371

68

6

8

795

375

69

6

9

805

380

70

7

0

814

384

71

7

1

823

389

72

7

2

833

393

73

7

3

842

397

74

7

4

852

402

75

7

5

861

406

76

7

6

870

411

77

7

7

880

415

78

7

8

889

419

79

7

9

898

424

80

8

0

908

428

81

8

1

917

433

82

8

2

926

437

83

8

3

936

442

84

8

4

945

446

85

8

5

954

450

86

8

6

964

455

87

8

7

973

459

88

8

8

982

464

89

8

9

992

468

90

9

0

1001

472

91

9

1

1010

477

92

9

2

1020

481

93

9

3

1029

486

94

9

4

1038

490

95

9

5

1048

494

96

9

6

1057

499

97

9

7

1066

503

98

9

8

1076

508

99

9

9

1085

512

100

0

0

34

VAV-SVN01E-EN

Image 34
Contents Installation Operator Maintenance JuneAmerican Standard All rights reserved Contents Fiberglass Wool Single-Duct Units Vcef Door Interlocking Power Disconnect Digit 7, 8-Secondary AirValve Dual-Duct UnitsDigit 1, 2, 3-UnitType Digit 9-Not UsedFan-Powered Parallel Units Vpef Door Interlocking Power DisconnectService Model Number Description Digit 32-Airflow SwitchVsef Door Interlocking Power Disconnect Fan-Powered Series UnitsFan Note See fan curves for specific airflows Digit 27, 28, 29-Electric Heat Kilowatts Fan-Powered Low-Height Parallel Units Lpef Door Interlocking Power DisconnectDigit 27, 28, 29-Electric HeatVoltage Fan-Powered Low-Height Series Units Lsef Door Interlocking Power DisconnectDigit 32-Air Flow Switch General Information Literature ContentsReceiving and Handling Single-Duct Units Unit InformationDual-Duct Units Fan-Powered and Fan-Powered Low-Height Units Typical Fan-Powered UnitsSingle-Duct Unit InstallationDual-Duct Fan-Powered Standard and Low- Height Parallel Hanger Bracket Locations SizesSeries Hanger Bracket Locations Low-Height Parallel 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Parallel10SQ Low-Height Series 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Series 10SQ w/ Hot Water or Electric Heat Attenuator Installation-Parallel Units Attenuator Installation-Series Units Attenuator Installation-Low-Height Parallel Units Attenuator Installation-Low-Height Series Units Chart 1 UnitWeights Parallel Fan-Powered UnitsVsef w Series Fan-Powered UnitVscf w Low-Height Parallel UnitsEquipment Damage Chart 3- Fan Motor Amperage Unit SetupChart 2 Flow Sensor Delta P vs.Airflow Delivery Maximum PSC Fan MotorAmperage FLAHazardousVoltage Electrically Commutated Motor ECMVPxF 03SQ Chart 4 -VPxF 03SQ ECM CFMTableMotor Min CFM Motor Max CFM Chart 5 -VPxF 04SQ ECM CFMTable VPxF 04SQChart 6 -VPxF 05SQ ECM CFMTable VPxF 05SQChart 7 -VPxF 06SQ ECM CFMTable VPxF 06SQChart 8 -VSxF 03SQ ECM CFMTable VSxF 03SQChart 9-VSxF 04SQ ECM CFMTable VSxF 04SQChart 10-VSxF 05SQ ECM CFMTable VSxF 05SQChart 11-VSxF 06SQ ECM CFMTable VSxF 06SQChart 12- LPxF 08SQ ECM CFMTable LPxF 08SQChart 13- LPxF 09SQ ECM CFMTable LPxF 09SQChart 14- LSxF 08SQ ECM CFMTable LSxF 08SQChart 15- LSxF 09SQ ECM CFMTable LSxF 09SQChart 15- LSxF 10SQ ECM CFMTable LSxF 10SQWiring Diagrams Single-Duct Units Electronic or DDC/UCMSingle-Duct Units Pneumatic Controls Fan-Powered Units Electronic or DDC/UCM Fan-Powered Units Pneumatic Controls Fan-Powered Control Boxes Fan-Powered Units with ECM Fan-Powered Low-Height Units Fan-Powered Low-Height Units with ECM Maintenance Rotating ComponentsBar Ceiling Installation of DiffusersGeneral Concealed Spline CeilingMaintenance/ Service Log Date Tag Serial # Service NotesMaintenance/ Service Log VAV-SVN01E-EN Trane

VAV-SVN01E-EN, Trane specifications

The Trane VAV-SVN01E-EN is an advanced variable air volume (VAV) system designed to optimize indoor air quality and energy efficiency in commercial buildings. This system is part of Trane’s commitment to offering reliable, innovative HVAC solutions that meet the demands of modern architectural designs and energy standards.

One of the main features of the VAV-SVN01E-EN is its ability to control air flow based on occupancy and environmental conditions. This ensures that energy is used efficiently, as airflow can be adjusted to match real-time needs, rather than operating at a constant rate. The integration of intelligent sensors allows the system to adapt dynamically, leading to both reduced energy consumption and improved comfort for building occupants.

The technology behind the VAV-SVN01E-EN includes advanced digital controls and integration capabilities. These controls enable the system to communicate seamlessly with building management systems (BMS), allowing for centralized monitoring and management. This interconnected approach not only enhances operational efficiency but also enables predictive maintenance, helping facility managers identify and address potential issues before they become problematic.

Energy efficiency is further enhanced through the use of VAV technology, which reduces the amount of conditioned air delivered when spaces are unoccupied or when less cooling or heating is required. This tailored approach contributes to lower energy costs and supports sustainability initiatives by decreasing the overall carbon footprint of the building.

Key characteristics of the Trane VAV-SVN01E-EN include its compact design, which facilitates easy installation in existing spaces without significant modifications. The unit is also designed for low sound levels, ensuring that it operates quietly, contributing to a more pleasant indoor environment. Moreover, the VAV system is engineered to be reliable and durable, with rigorous testing and high-quality components ensuring long-term performance.

In summary, the Trane VAV-SVN01E-EN stands out in the field of HVAC solutions, bringing together advanced technology, energy efficiency, and user comfort. Its features are tailored for modern building requirements, making it a preferred choice for facility managers aiming to enhance indoor air quality while reducing operational costs.