Trane VAV-SVN01E-EN, Trane manual Chart 15- LSxF 10SQ ECM CFMTable

Page 46

Unit

Setup

Chart 15– LSxF 10SQ ECM CFMTable

LSxF 10SQ

Motor Min CFM: 400

Motor Max CFM: 1800

 

 

%

TENS

UNITS

CFM

L/sec

Setting

Switch

Switch

400

189

1

0

1

414

196

2

0

2

428

202

3

0

3

443

209

4

0

4

457

216

5

0

5

471

222

6

0

6

485

229

7

0

7

499

236

8

0

8

513

242

9

0

9

527

249

10

1

0

542

256

11

1

1

556

262

12

1

2

570

269

13

1

3

584

276

14

1

4

598

282

15

1

5

612

289

16

1

6

626

296

17

1

7

641

302

18

1

8

655

309

19

1

9

669

316

20

2

0

683

322

21

2

1

697

329

22

2

2

711

336

23

2

3

725

342

24

2

4

740

349

25

2

5

754

356

26

2

6

768

362

27

2

7

782

369

28

2

8

796

376

29

2

9

810

382

30

3

0

824

389

31

3

1

838

396

32

3

2

853

402

33

3

3

867

409

34

3

4

881

416

35

3

5

895

422

36

3

6

909

429

37

3

7

923

436

38

3

8

937

442

39

3

9

952

449

40

4

0

966

456

41

4

1

980

462

42

4

2

994

469

43

4

3

1008

476

44

4

4

1022

482

45

4

5

1036

489

46

4

6

1051

496

47

4

7

1065

502

48

4

8

1079

509

49

4

9

1093

516

50

5

0

 

 

%

TENS

UNITS

CFM

L/sec

Setting

Switch

Switch

1107

523

51

5

1

1121

529

52

5

2

1135

536

53

5

3

1150

543

54

5

4

1164

549

55

5

5

1178

556

56

5

6

1192

563

57

5

7

1206

569

58

5

8

1220

576

59

5

9

1234

583

60

6

0

1249

589

61

6

1

1263

596

62

6

2

1277

603

63

6

3

1291

609

64

6

4

1305

616

65

6

5

1319

623

66

6

6

1333

629

67

6

7

1348

636

68

6

8

1362

643

69

6

9

1376

649

70

7

0

1390

656

71

7

1

1404

663

72

7

2

1418

669

73

7

3

1432

676

74

7

4

1447

683

75

7

5

1461

689

76

7

6

1475

696

77

7

7

1489

703

78

7

8

1503

709

79

7

9

1517

716

80

8

0

1531

723

81

8

1

1545

729

82

8

2

1560

736

83

8

3

1574

743

84

8

4

1588

749

85

8

5

1602

756

86

8

6

1616

763

87

8

7

1630

769

88

8

8

1644

776

89

8

9

1659

783

90

9

0

1673

789

91

9

1

1687

796

92

9

2

1701

803

93

9

3

1715

809

94

9

4

1729

816

95

9

5

1743

823

96

9

6

1758

829

97

9

7

1772

836

98

9

8

1786

843

99

9

9

1800

850

100

0

0

46

VAV-SVN01E-EN

Image 46
Contents Installation Operator Maintenance JuneAmerican Standard All rights reserved Contents Fiberglass Wool Single-Duct Units Vcef Door Interlocking Power Disconnect Digit 7, 8-Secondary AirValve Dual-Duct UnitsDigit 1, 2, 3-UnitType Digit 9-Not UsedFan-Powered Parallel Units Vpef Door Interlocking Power DisconnectService Model Number Description Digit 32-Airflow SwitchVsef Door Interlocking Power Disconnect Fan-Powered Series UnitsFan Note See fan curves for specific airflows Digit 27, 28, 29-Electric Heat Kilowatts Fan-Powered Low-Height Parallel Units Lpef Door Interlocking Power DisconnectDigit 27, 28, 29-Electric HeatVoltage Fan-Powered Low-Height Series Units Lsef Door Interlocking Power DisconnectDigit 32-Air Flow Switch General Information Literature ContentsReceiving and Handling Single-Duct Units Unit InformationDual-Duct Units Fan-Powered and Fan-Powered Low-Height Units Typical Fan-Powered UnitsSingle-Duct Unit InstallationDual-Duct Fan-Powered Standard and Low- Height Parallel Hanger Bracket Locations SizesSeries Hanger Bracket Locations Low-Height Parallel 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Parallel10SQ Low-Height Series 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Series 10SQ w/ Hot Water or Electric Heat Attenuator Installation-Parallel Units Attenuator Installation-Series Units Attenuator Installation-Low-Height Parallel Units Attenuator Installation-Low-Height Series Units Chart 1 UnitWeights Parallel Fan-Powered UnitsVsef w Series Fan-Powered UnitVscf w Low-Height Parallel UnitsEquipment Damage Chart 3- Fan Motor Amperage Unit SetupChart 2 Flow Sensor Delta P vs.Airflow Delivery Maximum PSC Fan MotorAmperage FLAHazardousVoltage Electrically Commutated Motor ECMVPxF 03SQ Chart 4 -VPxF 03SQ ECM CFMTableMotor Min CFM Motor Max CFM Chart 5 -VPxF 04SQ ECM CFMTable VPxF 04SQChart 6 -VPxF 05SQ ECM CFMTable VPxF 05SQChart 7 -VPxF 06SQ ECM CFMTable VPxF 06SQChart 8 -VSxF 03SQ ECM CFMTable VSxF 03SQChart 9-VSxF 04SQ ECM CFMTable VSxF 04SQChart 10-VSxF 05SQ ECM CFMTable VSxF 05SQChart 11-VSxF 06SQ ECM CFMTable VSxF 06SQChart 12- LPxF 08SQ ECM CFMTable LPxF 08SQChart 13- LPxF 09SQ ECM CFMTable LPxF 09SQChart 14- LSxF 08SQ ECM CFMTable LSxF 08SQChart 15- LSxF 09SQ ECM CFMTable LSxF 09SQChart 15- LSxF 10SQ ECM CFMTable LSxF 10SQWiring Diagrams Single-Duct Units Electronic or DDC/UCMSingle-Duct Units Pneumatic Controls Fan-Powered Units Electronic or DDC/UCM Fan-Powered Units Pneumatic Controls Fan-Powered Control Boxes Fan-Powered Units with ECM Fan-Powered Low-Height Units Fan-Powered Low-Height Units with ECM Maintenance Rotating ComponentsBar Ceiling Installation of DiffusersGeneral Concealed Spline CeilingMaintenance/ Service Log Date Tag Serial # Service NotesMaintenance/ Service Log VAV-SVN01E-EN Trane

VAV-SVN01E-EN, Trane specifications

The Trane VAV-SVN01E-EN is an advanced variable air volume (VAV) system designed to optimize indoor air quality and energy efficiency in commercial buildings. This system is part of Trane’s commitment to offering reliable, innovative HVAC solutions that meet the demands of modern architectural designs and energy standards.

One of the main features of the VAV-SVN01E-EN is its ability to control air flow based on occupancy and environmental conditions. This ensures that energy is used efficiently, as airflow can be adjusted to match real-time needs, rather than operating at a constant rate. The integration of intelligent sensors allows the system to adapt dynamically, leading to both reduced energy consumption and improved comfort for building occupants.

The technology behind the VAV-SVN01E-EN includes advanced digital controls and integration capabilities. These controls enable the system to communicate seamlessly with building management systems (BMS), allowing for centralized monitoring and management. This interconnected approach not only enhances operational efficiency but also enables predictive maintenance, helping facility managers identify and address potential issues before they become problematic.

Energy efficiency is further enhanced through the use of VAV technology, which reduces the amount of conditioned air delivered when spaces are unoccupied or when less cooling or heating is required. This tailored approach contributes to lower energy costs and supports sustainability initiatives by decreasing the overall carbon footprint of the building.

Key characteristics of the Trane VAV-SVN01E-EN include its compact design, which facilitates easy installation in existing spaces without significant modifications. The unit is also designed for low sound levels, ensuring that it operates quietly, contributing to a more pleasant indoor environment. Moreover, the VAV system is engineered to be reliable and durable, with rigorous testing and high-quality components ensuring long-term performance.

In summary, the Trane VAV-SVN01E-EN stands out in the field of HVAC solutions, bringing together advanced technology, energy efficiency, and user comfort. Its features are tailored for modern building requirements, making it a preferred choice for facility managers aiming to enhance indoor air quality while reducing operational costs.