Trane VAV-SVN01E-EN, Trane manual Chart 6 -VPxF 05SQ ECM CFMTable

Page 36

Unit

Setup

Chart 6 –VPxF 05SQ ECM CFMTable

VPxF 05SQ

Motor Min CFM: 280

Motor Max CFM: 1850

 

%

 

TENS

UNITS

CFM

L/sec

Setting

Switch

Switch

280

132

1

0

1

296

140

2

0

2

312

147

3

0

3

327

155

4

0

4

343

162

5

0

5

359

170

6

0

6

375

177

7

0

7

391

184

8

0

8

407

192

9

0

9

423

199

10

1

0

438

207

11

1

1

454

214

12

1

2

470

222

13

1

3

486

229

14

1

4

502

237

15

1

5

518

244

16

1

6

534

252

17

1

7

549

259

18

1

8

565

267

19

1

9

581

274

20

2

0

597

282

21

2

1

613

289

22

2

2

629

297

23

2

3

645

304

24

2

4

661

312

25

2

5

676

319

26

2

6

692

327

27

2

7

708

334

28

2

8

724

342

29

2

9

740

349

30

3

0

756

357

31

3

1

772

364

32

3

2

787

372

33

3

3

803

379

34

3

4

819

387

35

3

5

835

394

36

3

6

851

402

37

3

7

867

409

38

3

8

883

417

39

3

9

898

424

40

4

0

914

431

41

4

1

930

439

42

4

2

946

446

43

4

3

962

454

44

4

4

978

461

45

4

5

994

469

46

4

6

1009

476

47

4

7

1025

484

48

4

8

1041

491

49

4

9

1057

499

50

5

0

 

 

%

TENS

UNITS

CFM

L/Sec

Setting

Switch

Switch

1073

506

51

5

1

1089

514

52

5

2

1105

521

53

5

3

1120

529

54

5

4

1136

536

55

5

5

1152

544

56

5

6

1168

551

57

5

7

1184

559

58

5

8

1200

566

59

5

9

1216

574

60

6

0

1231

581

61

6

1

1247

589

62

6

2

1263

596

63

6

3

1279

604

64

6

4

1295

611

65

6

5

1311

619

66

6

6

1327

626

67

6

7

1342

634

68

6

8

1358

641

69

6

9

1374

649

70

7

0

1390

656

71

7

1

1406

664

72

7

2

1422

671

73

7

3

1438

678

74

7

4

1454

686

75

7

5

1469

693

76

7

6

1485

701

77

7

7

1501

708

78

7

8

1517

716

79

7

9

1533

723

80

8

0

1549

731

81

8

1

1565

738

82

8

2

1580

746

83

8

3

1596

753

84

8

4

1612

761

85

8

5

1628

768

86

8

6

1644

776

87

8

7

1660

783

88

8

8

1676

791

89

8

9

1691

798

90

9

0

1707

806

91

9

1

1723

813

92

9

2

1739

821

93

9

3

1755

828

94

9

4

1771

836

95

9

5

1787

843

96

9

6

1802

851

97

9

7

1818

858

98

9

8

1834

866

99

9

9

1850

873

100

0

0

36

VAV-SVN01E-EN

Image 36
Contents Installation Operator Maintenance JuneAmerican Standard All rights reserved Contents Fiberglass Wool Single-Duct Units Vcef Door Interlocking Power Disconnect Dual-Duct Units Digit 1, 2, 3-UnitTypeDigit 7, 8-Secondary AirValve Digit 9-Not UsedFan-Powered Parallel Units Vpef Door Interlocking Power DisconnectService Model Number Description Digit 32-Airflow SwitchFan-Powered Series Units Vsef Door Interlocking Power DisconnectFan Note See fan curves for specific airflows Digit 27, 28, 29-Electric Heat Kilowatts Fan-Powered Low-Height Parallel Units Lpef Door Interlocking Power DisconnectDigit 27, 28, 29-Electric HeatVoltage Fan-Powered Low-Height Series Units Lsef Door Interlocking Power DisconnectDigit 32-Air Flow Switch Literature Contents General InformationReceiving and Handling Unit Information Single-Duct UnitsDual-Duct Units Fan-Powered and Fan-Powered Low-Height Units Typical Fan-Powered UnitsUnit Installation Single-DuctDual-Duct Fan-Powered Standard and Low- Height Parallel Hanger Bracket Locations SizesSeries Hanger Bracket Locations Low-Height Parallel 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Parallel10SQ Low-Height Series 08SQ/09SQ w/ Hot Water or Electric Heat Low-Height Series 10SQ w/ Hot Water or Electric Heat Attenuator Installation-Parallel Units Attenuator Installation-Series Units Attenuator Installation-Low-Height Parallel Units Attenuator Installation-Low-Height Series Units Chart 1 UnitWeights Parallel Fan-Powered UnitsSeries Fan-Powered Unit Vscf wVsef w Low-Height Parallel UnitsEquipment Damage Unit Setup Chart 2 Flow Sensor Delta P vs.Airflow DeliveryChart 3- Fan Motor Amperage Maximum PSC Fan MotorAmperage FLAHazardousVoltage Electrically Commutated Motor ECMChart 4 -VPxF 03SQ ECM CFMTable VPxF 03SQMotor Min CFM Motor Max CFM Chart 5 -VPxF 04SQ ECM CFMTable VPxF 04SQChart 6 -VPxF 05SQ ECM CFMTable VPxF 05SQChart 7 -VPxF 06SQ ECM CFMTable VPxF 06SQChart 8 -VSxF 03SQ ECM CFMTable VSxF 03SQChart 9-VSxF 04SQ ECM CFMTable VSxF 04SQChart 10-VSxF 05SQ ECM CFMTable VSxF 05SQChart 11-VSxF 06SQ ECM CFMTable VSxF 06SQChart 12- LPxF 08SQ ECM CFMTable LPxF 08SQChart 13- LPxF 09SQ ECM CFMTable LPxF 09SQChart 14- LSxF 08SQ ECM CFMTable LSxF 08SQChart 15- LSxF 09SQ ECM CFMTable LSxF 09SQChart 15- LSxF 10SQ ECM CFMTable LSxF 10SQWiring Diagrams Single-Duct Units Electronic or DDC/UCMSingle-Duct Units Pneumatic Controls Fan-Powered Units Electronic or DDC/UCM Fan-Powered Units Pneumatic Controls Fan-Powered Control Boxes Fan-Powered Units with ECM Fan-Powered Low-Height Units Fan-Powered Low-Height Units with ECM Maintenance Rotating ComponentsInstallation of Diffusers GeneralBar Ceiling Concealed Spline CeilingMaintenance/ Service Log Date Tag Serial # Service NotesMaintenance/ Service Log VAV-SVN01E-EN Trane

VAV-SVN01E-EN, Trane specifications

The Trane VAV-SVN01E-EN is an advanced variable air volume (VAV) system designed to optimize indoor air quality and energy efficiency in commercial buildings. This system is part of Trane’s commitment to offering reliable, innovative HVAC solutions that meet the demands of modern architectural designs and energy standards.

One of the main features of the VAV-SVN01E-EN is its ability to control air flow based on occupancy and environmental conditions. This ensures that energy is used efficiently, as airflow can be adjusted to match real-time needs, rather than operating at a constant rate. The integration of intelligent sensors allows the system to adapt dynamically, leading to both reduced energy consumption and improved comfort for building occupants.

The technology behind the VAV-SVN01E-EN includes advanced digital controls and integration capabilities. These controls enable the system to communicate seamlessly with building management systems (BMS), allowing for centralized monitoring and management. This interconnected approach not only enhances operational efficiency but also enables predictive maintenance, helping facility managers identify and address potential issues before they become problematic.

Energy efficiency is further enhanced through the use of VAV technology, which reduces the amount of conditioned air delivered when spaces are unoccupied or when less cooling or heating is required. This tailored approach contributes to lower energy costs and supports sustainability initiatives by decreasing the overall carbon footprint of the building.

Key characteristics of the Trane VAV-SVN01E-EN include its compact design, which facilitates easy installation in existing spaces without significant modifications. The unit is also designed for low sound levels, ensuring that it operates quietly, contributing to a more pleasant indoor environment. Moreover, the VAV system is engineered to be reliable and durable, with rigorous testing and high-quality components ensuring long-term performance.

In summary, the Trane VAV-SVN01E-EN stands out in the field of HVAC solutions, bringing together advanced technology, energy efficiency, and user comfort. Its features are tailored for modern building requirements, making it a preferred choice for facility managers aiming to enhance indoor air quality while reducing operational costs.