Self-Contained Model Number Continued — Digit 25 - Industrial Options

A = Protective Coating Evaporator Coil

B = Silver Solder

C = Stainless Steel Screws

D = A and B

E = A and C

F = B and C

G = A, B, and C

0 = None

Digit 26 - Drain PanType

A = Galvanized Sloped

B = Stainless Steel Sloped

Digit 27 - Waterside Economizer

A = Mechanical Clean Full Capacity (4-row)

B = Mechanical Clean Low Capacity (2-row)

C = Chemical Clean Full Capacity (4-row)

D = Chemical Clean Low Capacity (2-row)

0 = None

Digit 28 -Ventilation Control

B = Airside Econ w/TraqDamper (Top O/A)

C = Airside Econ w/ Standard Damper (Top O/A)

E = Airside Econ w/TraqDamper and Comparative Enthalpy

(Top O/A)

F = Airside Econ w/ Standard Damper and Comparative Enthalpy (Top O/A)

H = None, 2-Position Damper Ventilation Interface

J = Airside Economizer Interface

K = Airside Economizer Interface w/ Comparative Enthalpy

Digit 29 - Water Piping

D = Left Hand Basic Piping

F = Left Hand Intermediate Piping K = Left Hand Basic w/ Flow Switch M = Left Hand Intermediate

w/ Flow Switch 0 = None

Digit 30 - CondenserTube Type

A= Standard CondenserTubes B = 90/10 CuNi CondenserTubes 0 = None (Air-cooled Only)

Digit 31 - Compressor Service Valves

1= With Service Valves

0 = None

Digit 32 - Miscellaneous System Control 1 =Timeclock

2 = Interface for Remote HI (IPCB)

3 = Dirty Filter Switch

4 = 1 and 2

5 = 1 and 3

6 = 2 and 3

7 = 1, 2 and 3

0 = None

Digit 33 - Control Interface Options

A = Generic BAS Module (GBAS)

B =Ventilation Override Module

(VOM)

C=Tracer Comm. Interface Module (TCI)

D = Remote Human Interface (RHI) E = GBAS and TCI

F = VOM and TCI

G = GBAS and VOM

H = GBAS and RHI

J = VOM and RHI

K = TCI and RHI

L = GBAS, VOM, and TCI M = GBAS, VOM, and RHI N = GBAS, TCI, and RHI P = VOM, TCI, and RHI

R = GBAS, VOM, TCI, and RHI 0 = None

Digit 34 - Agency

T = UL Agency Listing

0 = None

Digit 35 - Filter Type

1 = Construction Throwaway

2 = Med Eff. Throwaway

Digit 36 - Miscellaneous Control Option

A = Low Entering AirTemp. Protect

Device (LEATPD)

B= High DuctTempT-Stat (Ship Separate)

C = Plenum High Static Switch

(Ship Separate)

E = A and B

F = A and C

H = B and C

L = A, B, and C

0 = None

Self-Contained Accessory Model Number Description

P

S

W

F

S

1

2

3

4

5

Digit 1 - Parts/Accessories

P = Parts/Accessories

Digit 2 - Unit Model

S= Self-Contained

Digit 3 - Shipment

W = With Unit

Digit 4 - Development Sequence

F = Signature Series

G = Modular Series

Digit 5 - Sensors and Other Accessories

S = Sensors

Digit 6 - Sensors (Field Installed)

A = BAYSENS017 - ZoneTemp Only (CV andVAV)

B = BAYSENS013 - ZoneTemp with Timed Override Button (CV andVAV)

A

1

1

0

AO

6

7

8

9

10 11

C = BAYSENS014 - ZoneTemp with Timed Override Button, Setpoint Dial (CV andVAV)

E = BAYSENS008 - CV Zone Sensor

F = BAYSENS010 - CV Zone Sensor with Indicator Lights

G = BAYSENS019 - CV Programmable Night Setback Sensor

H = BAYSENS021 - VAV Zone Sensor with Indicator Lights

J = BAYSENS020 - VAV Programmable Night Setback Sensor

K = Remote Sensor Kit

L= Outside AirTemperature Sensor Kit M = Outside Air Humidity Sensor Kit

0 = None

Digit 7 - Low Entering Air Temperature Protection Device (Field Installed)

1= Low Entering AirTempeature Protection Device

0 = None

Digit 8 - Carbon Dioxide Sensor (field installed)

1 = Carbon Dioxide Sensor Kit

0 = None

Digit 9 - Not Used

0 = None

Digit 10, 11 - Design Sequence

A0 = A Design

PKG-PRC002-EN

15

Image 15
Contents December Commercial Self-ContainedSignature Series Self-Contained Units IntroductionContents Features and Benefits Optional Features Standard FeaturesIntegrated Comfort System ICS Integrated Self-Contained SystemsProven DesignThroughTesting and Research Trane 3-DScroll CompressorLow Torque Variation Equipment Room Location and Orientation Application Considerations Self-ContainedReturn Air Ductwork Supply Air DuctworkCondenser Water Piping Isolation RecommendationsUnit Operating Limits Condenser ApplicationAir Cooled ConsiderationsWaterside Economizer Capacity Procedure Self-ContainedSelection Unit CapacitiesUnit Selection Selection Example Design ConditionsSelf-Contained Model Number Description ProcedureModel Number DescriptionSelf-Contained Accessory Model Number Description Remote Air-Cooled Condenser Model Number Description Tons General DataTable GD-3. SCWF/SIWF Water-Cooled Self-Contained, 42-80Tons Table GD-4. SCRF/SIRF Air-Cooled Self-Contained SCRF/SIRFCCRC/CIRC General DataTable GD-7. Self-Contained Heating Coil Heating CoilDrops Drops Chart PD-5. Airside Pressure DropPerformance DataHeating Coils Airside Pressure20 to 38 Ton Unit 42 to 80 Ton Unit Discharge PlenumAirside Pressure Airside Economizer with Standard Damper Airside Economizer with Traq Damper Chart PD-21. Waterside Pressure Drop SCWF/SIWF 35 WatersidePressure Drop SCWF/SIWF Table PD-1. CFM Capacity Correction Table Performance Water-Cooled DataTable PD-3. SCWF/SIWF 20 Economizer Low Capacity 8,000 cfm Water-Cooled20 Ton Table PD-2. SCWF/SIWF 20 Economizer Full Capacity 8,000 cfmEntering WaterTemp Entering Air 75 F 85 F 95 F 22 Ton Table PD-5. SCWF/SIWF 22 Economizer Full Capacity 8,800 cfmTable PD-6. SCWF/SIWF 22 Economizer Low Capacity 8,800 cfm EnteringWaterTemp Entering Air 75 F 85 F 95 F Table PD-9. SCWF/SIWF 25 Economizer Low Capacity 10,000 cfm 25 TonEntering Water Temp Entering Air 75 F 85 F 95 F Table PD-12. SCWF/SIWF 29 Economizer Low Capacity 11,600 cfm 29 Ton84.2 Table PD-15. SCWF/SIWF 32 Economizer Low Capacity 12,800 cfm 32 Ton94.5 Table PD-18. SCWF/SIWF 35 Economizer Low Capacity 14,000 cfm 35 Ton401 320 Table PD-21. SCWF/SIWF 38 Economizer Low Capacity 15,200 cfm 38 Ton434 373 Table PD-24. SCWF/SIWF 42 Economizer Low Capacity 16,800 cfm 42 Ton403 84.1 Table PD-27. SCWF/SIWF 46 Economizer Low Capacity 18,400 cfm 46 Ton83.8 Table PD-30. SCWF/SIWF 52 Economizer Low Capacity 20,800 cfm 52 Ton596 471 Table PD-33. Scwfsiwf 58 Economizer Low Capacity 23,200 cfm 58 Ton663 571 Table PD-36. SCWF/SIWF 65 Economizer Low Capacity 26,000 cfm 65 TonEntering Water Temp Entering Air Table PD-39. SCWF/SIWF 72 Economizer Low Capacity 28,000 cfm 72 Ton83.7 Table PD-42. SCWF/SIWF 80 Economizer Low Capacity 29,800 cfm 80 Ton891 761 Air-Cooled Table PD-45. SCRF/SIRF 25 Gross Cooling Capacity 11,600 cfm Table PD-46. SCRF/SIRF 29 Gross Cooling Capacity 12,800 cfm Table PD-47. SCRF/SIRF 30 Gross Cooling Capacity 14,000 cfm 30 TonTable PD-48. SCRF/SIRF 35 Gross Cooling Capacity 15,200 cfm Table PD-49. SCRF/SIRF 40 Gross Cooling Capacity 18,400 cfm 40 TonTable PD-50. SCRF/SIRF 50 Gross Cooling Capacity 23,200 cfm 50 TonPerformance Air-Cooled Data60-TonTable PD-51. SCRF/SIRF 60 Gross Cooling Capacity 29,800 cfm Table PD-53. Steam Heating Capacity Self-ContainedHeating Coils Table PD-52. HotWater Heating CapacityAvailable Input and Output Points ControlsMain menus of the human interface panels are Standard IntelliPak Unit Control FeaturesIntelliPak Unit Features Human Interface Panel HISequence Controls OperationControl Sequences Operation Demand Limiting Binary Input Generic Building Automation System Module Gbas OptionGbas Analog Inputs Gbas Binary OutputsInlet GuideVane Control Airside OptionsAir-Cooled Condensers Water PurgeHeating Hot Water or Steam Occupied ZoneTemperature ControlUnoccupied ZoneTemperature Control Cooling and Heating Heating ElectricSupply Air Temperature Control Unit Sequence Operation Supply Air Setpoint ResetSupply Air Tempering Hot Water and Steam Units Only Model Number Digit 6 = A, BAYSENS017 Zone SensorControls Options Standard On All UnitsThermometer to indicate temperature in the zone Setpoint thumbwheel for local setpoint adjustment Electrical Data Selection ProceduresElectrical Data SCWF/SCRF Table ED-6. Single Stage Electric Heat Electrical DataTable ED-7. CCRC/CIRC Condenser Electrical Data Ton Self-Contained Dimensions Self-Contained Weights TonsDimensions Self-Contained Weights 40-80 Ton Detail a Electrical Connections Detail B Discharge DimensionsDischarge Dimensions English inches Discharge Dimensions Metric mmCcrc Unit Dimensions Dimensions Air-Cooled Weights CondenserFront View Looking at Control Panel DimensionsWeights Refrigerant and Electrical ConnectionsSteam Coil Hot Water CoilFlexible Horizontal Discharge Plenum DimensionsPlenum Dimensions English inches Plenum Dimensions Metric mmAirside EconomizerAirside Economizer Airside Economizer Dimensions Metric mm Airside Economizer Dimensions English inchesDual Setpoint, Manual/Automatic Field-InstalledAdjustment Zone SensorsZone Temperature Sensor Only Function LightsProgrammable Night-Setback Sensor Self-Contained Models ServiceService/Code Clearance Requirements ClearancesTop View CCRC/CIRC 20 Top View CCRC/CIRC 35Top View CCRC/CIRC 50 Table W-3. Variable Frequency Drive Weights Dimensions WeightsTable W-1. Unit Weights SCWF/SCRF/SIWF/SIRF Table W-2. Unit Weights CCRC/CIRCSignature Series Self Contained Units Mechanical Specifications Self-ContainedMechanical Air-CooledSpecifications Condenser Self-Contained Options Mechanical Specifications OptionsAir Volume/Temperature Control Zone Temperature Control Supply Air Temperature Control with Inlet GuideVanesAirside Economizer Interface with Comparative Enthalpy Comparative Enthalpy ControlStandard Two-Position Damper Interface Airside Economizer InterfaceNon-fused Disconnect Switch Water Flow SwitchService Valves Low Entering Air Temperature Protection DeviceStainless Steel Drain Pan Protective Coating CabinetCoils Cupro-Nickel CondenserLiterature Order Number

PKG-PRC002-EN specifications

The Trane PKG-PRC002-EN is a groundbreaking packaged rooftop unit designed to meet the diverse needs of commercial and industrial spaces. This model showcases Trane’s commitment to innovation, energy efficiency, and reliability, making it a preferred choice for HVAC professionals and building owners alike.

One of the main features of the PKG-PRC002-EN is its high-efficiency design. This unit leverages advanced technologies to minimize energy consumption while ensuring optimal cooling and heating performance. Its efficient compressor, coupled with enhanced heat exchangers, significantly reduces operating costs and energy bills, aligning with today’s sustainability goals.

The PKG-PRC002-EN features a robust and durable construction, which translates to enhanced longevity and reduced maintenance requirements. Designed for ease of installation, the unit is compact and lightweight, facilitating seamless retrofitting and integration into existing systems. Furthermore, its accessible service panels allow for straightforward maintenance and repairs, thus minimizing downtime and service disruptions.

Equipped with Trane's advanced control technology, the PKG-PRC002-EN offers precise temperature management, ensuring consistent comfort across different zones within a building. The intuitive controls enable users to program schedules and adjust settings based on their specific needs, enhancing comfort while maximizing efficiency.

The model also incorporates advanced filtration options, improving indoor air quality by effectively reducing pollutants and allergens. This focus on health and safety is essential, especially in commercial settings where air quality can significantly impact occupant well-being and productivity.

Another notable characteristic of the PKG-PRC002-EN is its low noise levels during operation, which is essential for maintaining a conducive indoor environment in workplaces, retail spaces, or educational institutions. The unit's design minimizes sound transmission, creating a more pleasant atmosphere for occupants.

In summary, the Trane PKG-PRC002-EN is a highly efficient, reliable, and user-friendly rooftop unit that combines advanced technology with robust construction. Its energy-saving features, superior air quality options, and focus on quiet performance make it an excellent choice for modern commercial HVAC applications, ultimately contributing to sustainable building practices and enhanced occupant comfort.