Honeywell K9696V2 Point of Sale Hardware, External Modems, Configuring POS

Page 68

Multi-Media Unit: Installation Instructions

Fig. 48. FAULT RELAY connector on Multi-Media unit’s back-panel, showing connection to an external alarm panel.

Do not connect a device to CONTROL output 6 after enabling the FAULT RELAY.

Enabling the FAULT RELAY provides a status pulse at CONTROL 6, disabling it as a general-purpose output. Connecting a device to CONTROL 6 could interfere with the relay’s performance.

5.9Point of Sale Hardware

Cable

For a point-of-sale (POS) device or other data communication equipment (DCE), use a standard RS-232 cable with a female DB-9 connector.

5.9.1Configuring POS

For procedures on using the Data Recording tab in the Maintenance dialog, to configure POS devices, consult the Admin User Guide for Rapid Eye Multi-Media units.

5.10External Modems

At unit, connected to a network

You can connect an external modem to a LAN-based Multi-Media unit.

for POTS. Honeywell recommends a U.S. Robotics Sportster, transmitting at a least 33.6Kps, for POTS connections.

for ISDN. A U.S. Robotics Courier I-Modem is recommended for ISDN connections. Please refer to your modem manufacturer's documentation for the modem’s configuration.

For use of an external modem with a POTS-based Multi-Media unit, contact Honeywell Video Systems technical support, at: 1 (800) 796–2288; i.e., 1 (800) 796–CCTV.

5–10

Image 68
Contents Multi-Media Unit Page Issue Date Revisions Page Declaration of Conformity Page Table of Contents Index Frequent QuestionsFind-it Page Page Overview New to Multi-Media?Not new to Multi-Media? SoftwareCommunications Walking ThroughCameras Other Hardware Powering-up the Multi-Media unitAdmin and View Software Start Admin to create a Multi database Log on to a Multi database, or create one using AdminUsing Admin, add a site Database for MultiType of Connection Running ViewAdd information about the connection, and save it About connectionsLog on to View Testing a ConnectionTest the connection use View to run a Maintenance session Where To, Next? For More InformationBackground information Unpacking the Unit AudienceRoad map to field work Please do not remove factory seals on a Multi-Media unitPrinted matter Rear Panel ReferenceItem, one of each, unless otherwise noted Temperature USB port and Printer portReporting the Installation Powering the Multi-Media UnitPowering Up and Down Connecting a Camera Unit RecoveryNominal storage* camera-day time† minute Rapid Dome or Rapid Dome Gold dome systemsLocalView Securing a cameraReference HardwareMonitors To enable the locking of a LocalView functionsLocalView help on operator’s PC To change a LocalView password Network ConnectionRecording rate fps lowest cycle time sec OverviewUsing LocalView Onsite To assign an IP address to a unit using LocalViewFor a network without Dhcp What next?Using a PC Onsite To setup a terminal programTo connect a null-modem cable Null-modem cable comes with your Multi-Media unitMulti-Media Unit Installation Instructions Windows Click Start and point to … … then click Hypertrm.exe iconParameter Value To use the Multi-Media ShellField Name Default Address Shell command Command ResultMulti Shell Reference None, port1, port2, or internalDial-up Connection To return to the Multi-Media Shell after a time outModem Reference Field Testing a ConnectionDamaged or Missing Goods Upgrade CD-ROM To upgrade a Multi-Media unit’s software, onsiteUpgrading Unit Software Multi-Media unit without a CD-RW drivePlease continue Multi Software Road map for using Multi software to obtain videoWhy check a connection? To install Multi software Some versions of Windows need you to restart the PCUsing Admin Running AdminDouble-duty logon dialog Obtaining a Multi DbAfter adding security Click Save and Close To name a site Site identification checklistAdding Site Information Record of a Dial-up Connection Dealing with connectionsConfirmation To make a record of a dial-up connectionDealing with dial-up confusion IP Address is mandatory for a network connection Record of a Network ConnectionTo make a record of a network connection Checking for video Using View to ConnectFirewall reference Testing a Connection Maintenance Using MaintenanceTo run a maintenance session on a Rapid Eye site Logging on to ViewTime zone Testing a Connection TimeCrucial settings for reporting on video of events Conflicting time zones To indicate the time zone of a Multi-Media unitTime zone is set on a unit-by-unit basis Clock Automatic setting To respond to a notification of conflicting time zonesTo set a unit’s clock manually, using a PC’s Auto-synch statisticsTesting a Connection Camera Video tab in Maintenance session video feed adjustmentsTo obtain video from a live video session To configure a Rapid Eye site’s camerasObtaining Video Results What NextPlease continue Audio at a Multi-Media Site MicrophonesSelecting a microphone Placing a microphoneChecking for Audio Interference Preventive measuresTo enable talking to a site Audio for OperatorsAt View Operator’s PC To send and receive audio offsiteTo enable audio for use onsite, by LocalView To disable audio for LocalViewSecuring a Multi-Media unit To secure the unitUnit Hard Disk Detachable Camera I/OHard Disk Report To detach the sub-panelHardware Options Handle on mounted hard diskDaisy-chaining Domes Connecting a PTZ DomeConverter Technical Notes Configuring PTZ Driver name Baud rate Supported controller/dome AlphabeticalAlarm Sensors Inputs for SensorsInput Technical Notes Inputs to a Multi-Media unit, used by hardware devicesNo normally open NC normally closedControl Outputs System MonitoringAlarm panel Software setup To set the Fault Relay to triggerConfiguring POS Point of Sale HardwareExternal Modems At unit, connected to a networkUsing null-modem cable for installation of Multi-Media unit Port Use RestrictionsSerial connection Connect only to serial port COM USB port and Parallel portPlease continue Supporting an Installation Cannot connect to Multi-Media unit, using ViewBackground Frequently asked question Section No video is reaching ViewSee also PlanningCoaxial Cable GroundingElectrical Interference LightingHum bar Triaxial cableFind-it Knowledge BaseTables Use the same database created earlier, using Admin see on p IllustrationsDial-up Networking More FAQs More FAQs Find-itNetwork Connection More FAQs Find-it Site Information Checklist Organization personnel Personnel Name, telephone #, emailSite definition Rapid Eye site… Identification Communications to unit Connection Value Audio Microphone type Speaker type CommentsSite Information Checklist Find-it Sensor hardware Input Type NO, NC, EOL Description Site Information Checklist Find-it Multi-Media Unit Installation Instructions Index Multi-Media Unit Installation Instructions Index Page Page Page Page Honeywell Security France Honeywell Security Italia SpAHoneywell Security Espana Honeywell Security House Netherlands

K9696V2 specifications

The Honeywell K9696V2 is a state-of-the-art temperature control device designed for versatile applications in various heating and cooling systems. This advanced controller is known for its precision, reliability, and user-friendly interface, making it an essential component for modern HVAC setups.

One of the main features of the K9696V2 is its ability to support multiple control strategies. It can effectively manage single-stage and multi-stage heating and cooling systems, allowing it to be used in a wide range of residential and commercial applications. This flexibility ensures that users can easily integrate the controller into existing setups without significant modifications.

The K9696V2 incorporates advanced technologies such as microprocessor-based control. This ensures precise temperature management, enhancing comfort while minimizing energy consumption. It features a built-in temperature sensor that provides accurate readings, ensuring that the system operates within the desired range. Users can set temperature thresholds that the controller will maintain, making it ideal for environments where temperature stability is critical.

Another notable characteristic of the Honeywell K9696V2 is its user-friendly interface. The device is equipped with an intuitive digital display that provides real-time temperature readings and system status. Additionally, users can easily navigate through the menu to adjust settings without the need for complicated configurations, which is a significant advantage for both technicians and end-users.

The K9696V2 also offers robust communication capabilities. With support for various communication protocols, including Modbus and BACnet, the device can integrate seamlessly with building management systems. This connectivity allows for remote monitoring and control, giving facility managers greater oversight of their HVAC operations.

Finally, the Honeywell K9696V2 is designed with energy efficiency in mind. By optimizing system performance and providing precise control, this controller helps to reduce energy consumption, translating to cost savings for users. Its durable build ensures longevity, making it a worthy investment for those seeking reliable temperature control solutions.

Overall, the Honeywell K9696V2 stands out in the market due to its advanced features, adaptability, and user-centric design, making it a preferred choice for temperature control in a variety of settings.