REMOVING THE MECHANICAL HUMIDISTAT,
LIGHT, AND POWER SUPPLY CORD
Electrical Shock Hazard Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Unplug dehumidifier or disconnect power.
2.Remove the cabinet from the dehumidi- fier (see page
3.Pull the knob off the humidistat shaft.
4.Remove the two
Humidistat Knob
Mechanical Control Screws
5.Unsnap the four top cover tabs from the mechanical control and remove the cover.
Top Cover Tabs
6.To remove the mechanical humidistat:
a)Disconnect the brown wire and the connector with the two black wires from the mechanical humidistat termi- nals.
b)Unclip the humidistat from the cover and remove it.
7.To remove the light:
a)Disconnect the yellow and two white wires from the light terminals.
b)Unclip the light from the cover and re- move it.
YL 2 WH
2 BK BN
Mechanical |
| Humidistat | Light |
|