REMOVING THE ELECTRONIC CONTROL, THERMISTOR, AND POWER SUPPLY CORD
Electrical Shock Hazard Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Unplug dehumidifier or disconnect power.
2.Remove the cabinet from the dehumidi- fier (see page 
NOTE: The electronic control, thermistor, and power supply cord are 
Electronic
Control
Thermistor
Power
Supply
Cord
3.Disconnect the four wire connectors from the electronic control.
Electronic
Control ![]()
Black (Compressor)  | Orange  | White  | 
Black (Fan Motor)
4.Remove the two hex-head  screws from the electronic control.
Electronic Control Screws
Front View  | Bucket Switch  | 
Power Supply Cord
Rear View