Whirlpool AD35DSS, AD50DSS, AD70USS, AD50USS, AD25BSS, AD35USS Thermistor & Clip Ground Wire Screw

Page 21

5.Unclip the thermistor from the tubing and remove it. NOTE: Do not remove the thermistor from the clip.

6.Remove the hex-head screw from the green ground wire.

9.Remove the power supply cord from the cabinet.

Thermistor & Clip

Ground Wire Screw

7.On the rear of the unit, disconnect the two wires from the bucket switch termi- nals and unclip the wires.

8.Disconnect the indicated white control wire from the compressor capacitor terminal.

Bucket Switch Wires

White Control Wire

Compressor

Capacitor

Power Supply Cord

10.Remove the wiring from the three tabs, and remove the electronic control as- sembly from the dehumidifier.

Wire

Tabs

Electronic Control Assembly

3-5

Image 21
Contents Models AD25BSS, AD35DSS, AD50DSS DehumidifiersGoals and Objectives ForwardTable of Contents Page General Dehumidifier SafetyYou can be killed or seriously injured if you don’t Immediately follow instructionsModel Number Model & Serial Number DesignationsSerial Number AD = Dehumidifier, Whirlpool RD = Dehumidifier, RoperModel & Serial Number Wiring Diagram Label Locations Page Product Operation What is HUMIDITY?Theory of Operation Removing Unwanted HumidityTypical Operation Operating CharacteristicsPage Dehumidifier USE Empty/Adjust Bucket LightStarting/Stopping the Dehumidifier Control Type Fan Speed Control Type 2 Models OnlyDryness Control Starting/Stopping the DehumidifierFan Speed Control Type 3 Models Only Desired Humidity Control Type 3 Models Only Draining the DehumidifierOption 2-Connect Drain Hose Normal SoundsCleaning the AIR Filter on Some Models Cleaning the DehumidifierDehumidifier Care Component Locations Component AccessRemoving the Cabinet Top Rear Screws Rear Half Front Half Bottom Rear Screw Remove the two hex-head screws from the electronic control Thermistor & Clip Ground Wire Screw To remove the light To remove the mechanical humidistatTo remove the power supply cord Removing the FAN Capacitor and the FAN Motor To remove the fan capacitor see the top right photoTo remove the fan motor Top green ground wire on condenser To remove the compressor capacitor Removing the Compressor Capacitor and the Bucket SwitchMechanical Models To remove the bucket switch Electronic ModelPage Mechanical Humidistat FAN Capacitor Component TestingFAN Motor Bucket SwitchDiagnostics Diagnostics & TroubleshootingProblem Cause Correction TroubleshootingWiring Diagram Wiring DiagramsWiring Diagram Wiring Diagram Page Page Page Product Specifications Warranty Information Sources For Technical Information and Service PointersFor Technical Assistance While AT the CUSTOMER’S Home Call Corporation