DIAGNOSTICS & TROUBLESHOOTING
DIAGNOSTICS
1.Turn off the dehumidifier with the power button.
2.Remove the bucket.
3.Unplug the dehumidifier for at least 1 sec- ond.
4.Reconnect power.
5.Within 5 seconds of restoring power, com- plete the following
•If you press a wrong key during the
•After pressing the 3 keys in the correct order within 5 seconds, all the LEDs will light at Step 1 (see chart). Use the Desired Humidity key to advance the steps. Using any other key will exit diagnostics.
IMPORTANT: If you do not complete the diagnostics procedure within 15 minutes, the control will exit the diagnostics.
Step | Test | LED Name | LED Condition | |
1 | LEDs | All | All illuminate | |
|
|
| Blinking= Bucket | |
2a | Bucket switch | Bucket | removed (switch open) | |
ON solid= Bucket | ||||
|
|
| ||
|
|
| installed (switch closed) | |
|
|
|
| |
2b | Thermistor | Normal | On solid= Pass | |
Blinking= Fail | ||||
|
|
| ||
2c | Humidistat | Continuous | On solid= Pass | |
run | Blinking= Fail | |||
|
| |||
3 | HIGH speed fan | HIGH | ON solid, | |
confirm operation | ||||
|
|
| ||
4 | LOW speed fan | LOW | ON solid, | |
confirm operation | ||||
|
|
| ||
5 | Compressor | AUTO | ON solid, | |
(On for 20 seconds) | confirm operation | |||
|
| |||
Exit |
|
|
|