AMC2 4W | Installing en 29 |
Fig. 5.6 Location of the power supply connector
An external power supply (10 - 30V DC) must be connected for internal electronics at pin 1 (positive) and pin 3 (negative) of the pluggable screw connector.
When using a shared 12V DC power supply for internal electron- ics and peripherals, pin 1 and pin 6 resp. pin 3 and pin 7 can be shortened.
If an uninterruptible power supply (UPS) is used, the relay out- put for power good signals from the UPS is connected to the following pins:
•pin 4 and 7 for power good AC
•pin 5 and 7 for power good Battery
•pin 6 and 7 for power good DC Otherwise these pins must be
Bosch Security Systems | Installation manual | F.01U.024.965 V.4 2006.09 |