Bosch Appliances APC-AMC2-4WUS, APC-AMC2-4WCF installation manual Safety Instructions en

Page 9

AMC2 4W

Safety Instructions en 9

If the unit has been dropped or the cabinet damaged.

If the unit exhibits a distinct change in performance, this indicates that service is needed.

7.Replacement Parts - When replacement parts are required, the service technician shall use replacement parts that are specified by the manufacturer. Unauthorized substitutions may result in fire, electrical shock or other hazards.

8.Safety Check - Upon completion of service or repair work on the unit, ask the service technician to perform safety checks to ensure that the unit operates properly

9.Power Sources - Operate the unit only from the type of power source indicated on the label. If unsure of the type of power supply to use, contact your dealer

For units intended to operate from battery power, refer to the operating instructions.

For units intended to operate with External Power Supplies, use only the recommended approved power supplies.

For units intended to operate with a limited power source, this power source must comply with EN/UL 60950. Substitutions may damage the unit or cause fire or shock.

For units intended to operate at 12/24V DC normal input voltage is 12/24V DC. Voltages applied to the unit’s power input shall not exceed 15/30V DC.

10.Lightning - For added protection during a lightning storm, or when this unit is left unused for long periods of time, disconnect the unit from power. This will prevent damage to the unit due to lightning and excessive power line surges.

11.Restricted Access Locations are required for the installa- tion.

Bosch Security Systems

Installation manual

F.01U.024.965 V.4 2006.09

Image 9
Contents AMC2 4W Page Remarks Table of Contents Operating AppendixIndex AMC2 4W Explanation of Used Symbols Please read carefullyInternet Important Safety Notes Safety InstructionsSafety Instructions en FCC & Ices Information Safety Precautions Health and SafetyRead instructions Unpacking Description of the AMC2 4W IntroductionAMC2 4W in a four door safety lock Upper circuit board with display top side Equipment ConfigurationOverview Interfaces Jumper at the bottom side Performance Characteristics System overview System OverviewRTC Technical DataAMC 5VA Mounting InstallingDemounting Opening the AMC2 4W Case Conductor data for connection to power supply CablingGrounding and Shielding Location of ground jumper RS-485 host interface Grounding and Shielding the Host InterfaceAMC2 4W Grounding and Shielding the Extension Interface Connecting Power SupplyLocation of the power supply connector RS-485 Host Interface AMC2 4W RS-485 host interface 1 RS-485 Two Wire Connection10 Settings for RS-485 two wire connections 2 RS-485 Four Wire Connection12 Settings for RS-485 four wire connection DIL Switch Address SelectorAMC2 4W Address DIL Switches Mode DIL SwitchesRS-232 Host Interface 14 Location of the RS-232 serial interface Ethernet InterfaceIpconfig /flushdns Wiegand Interface for Card Readers RS-485 Extension Module Bus17 Location of the Wiegand interfaces for external devices 18 Location of the relay output connectors Connecting Relay Outputs19 Wet mode and dry mode of the AMC2 4W relay outputs Keep in mind the following specificationsRisk of Damage 20 Schema of the using of the recovery diode21 Location of relay output jumpers bottom side Connecting Analog Input DevicesComplete connection diagram of the analog input devices is Tamper Protection AMC2 4W Status Display of the AMC2 4W OperatingPush Display Example Description Dig. IODig Configuring the Ethernet Interface Resetting the AMC2 4WResetting the Software Restarting the AMC2 4W with the provided screw driver Resetting the Network ConfigurationsAMC2 4W Appendix Connecting DiagramsConnecting diagram of the RS-232 serial interface AMC2 4W Power supply Twisted pair connection Transmitter Receiver I L O P IndexPage Bosch Security Systems