5.4Cabling

CAUTION!

The cables used in the AMC2 4W access control system are not

!prone to electrical interference. However, you should avoid routing cables close to heavy load switching cables and equip-

ment. If this is unavoidable, cross the cable at right angles every 1 to 2 m (3 to 6 ft) to reduce interference.

Grounding and Shielding

The main grounding point at the AMC2 4W will be connected with pin 2 of the power supply connector - see Figure 7.6.

It is good practice to shield all wires carrying low level signals.

The AMC2 4W enables you to set up a central ground or shield- ing point, simply by setting a couple of jumpers. Set these jumpers only if ground or shield is not connected otherwise.

WARNING!

!Risk of damaging equipment!

When using multiple AMC2 4W devices, set the ground main jumper only once to assure a central point star connection.

5.4.1Conductor data for connection to power supply

For short distances below 25m (75 feet) use AWG18 conduc- tors. For higher distances install an additional power supply close to the AMC.

Please, calculate the voltage drop by checking the conductor specifications for characteristic resistance values. The voltage drop shall not exceed 2V.

Example:

Length = 100m/328 ft

Bosch Security Systems

Installation manual

F.01U.024.965 V.4 2006.09

Image 25
Contents AMC2 4W Page Remarks Table of Contents Appendix OperatingIndex AMC2 4W Please read carefully Explanation of Used SymbolsInternet Important Safety Notes Safety InstructionsSafety Instructions en FCC & Ices Information Health and Safety Safety PrecautionsRead instructions Unpacking Description of the AMC2 4W IntroductionAMC2 4W in a four door safety lock Upper circuit board with display top side Equipment ConfigurationOverview Interfaces Jumper at the bottom side Performance Characteristics System overview System OverviewRTC Technical DataAMC 5VA Mounting InstallingDemounting Opening the AMC2 4W Case Cabling Conductor data for connection to power supplyGrounding and Shielding Location of ground jumper RS-485 host interface Grounding and Shielding the Host InterfaceAMC2 4W Grounding and Shielding the Extension Interface Connecting Power SupplyLocation of the power supply connector RS-485 Host Interface AMC2 4W RS-485 host interface 1 RS-485 Two Wire Connection10 Settings for RS-485 two wire connections 2 RS-485 Four Wire Connection12 Settings for RS-485 four wire connection DIL Switch Address SelectorAMC2 4W Mode DIL Switches Address DIL SwitchesRS-232 Host Interface 14 Location of the RS-232 serial interface Ethernet InterfaceIpconfig /flushdns Wiegand Interface for Card Readers RS-485 Extension Module Bus17 Location of the Wiegand interfaces for external devices 18 Location of the relay output connectors Connecting Relay Outputs19 Wet mode and dry mode of the AMC2 4W relay outputs Keep in mind the following specificationsRisk of Damage 20 Schema of the using of the recovery diode21 Location of relay output jumpers bottom side Connecting Analog Input DevicesComplete connection diagram of the analog input devices is Tamper Protection AMC2 4W Status Display of the AMC2 4W OperatingDig. IO Push Display Example DescriptionDig Resetting the AMC2 4W Configuring the Ethernet InterfaceResetting the Software Restarting the AMC2 4W with the provided screw driver Resetting the Network ConfigurationsAMC2 4W Appendix Connecting DiagramsConnecting diagram of the RS-232 serial interface AMC2 4W Power supply Twisted pair connection Transmitter Receiver I L O P IndexPage Bosch Security Systems