båÅçêÉ=smñ=fåëí~ää~íáçå=dìáÇÉ
Installation
For this procedure, you will need:
Table 5. | Equipment List, Wide Screen Stack Configuration | ||
|
|
|
|
Qty. |
| Item | Note |
2 |
| VP | Master units (ID#1 and ID#2) must be VP, not VPx. |
|
|
|
|
2 |
| VP or VPx | The ID of the bottom stack processor must always be lower than the ID |
|
|
| of the top stack processor. Use 6 total processors for triple wide |
|
|
| screen, use 8 for quadruple wide, etc. |
1 |
| Controller | Model LC only |
|
|
|
|
2 |
| Video Projectors | Customer supplied |
|
|
|
|
4 |
| DVI or Analog Monitors | Program and Preview (customer supplied) |
|
|
|
|
1 |
| Ethernet Switch | Customer supplied |
|
|
|
|
5 |
| Ethernet cables | Customer supplied. Additional cables required for routers. |
|
|
|
|
TBD |
| Program Link Cables | Use 2 for double wide screen application, left justification |
|
|
|
|
|
|
| Use 4 for triple wide screen application, left justification |
|
|
|
|
|
|
| Use 4 for double wide screen application, center justification |
|
|
|
|
|
|
| Use 6 for triple wide screen application, center justification |
|
|
|
|
TDB |
| Source Link Cables | Minimum 4 for double wide screen application. |
|
|
|
|
TBD |
| Sources, routers, cables | Analog, Video and/or DVI as required (customer supplied) |
Use the following steps to install a wide screen “stack” configuration:
Important
It is recommended that each stack consists of two “fully loaded” processors, each with three M/Es. If necessary, you can use a
1.Software Version — Prior to connecting your VPx processor(s), ensure that software version 1.22 (or higher) is installed in your Encore Controller. Refer to Appendix C, “Upgrading Software” in the Encore Presentation System User’s Guide for complete upgrade instructions.
2.Follow the unpacking procedures as listed in the “Unpacking and Inspection” section on page 15.
3.Refer to the “Technical Specifications” section on page 28 for electrical and mechanical details.
4.Refer to the “VPx Hardware” section on page 8 for all connector locations.
5.For each VPx, follow the rack mount procedures as outlined in the
Important
Remember that master units (ID#1 and ID#2) must be VP, not VPx. “Slave” units can be VP or VPx.
24 |
| Encore VPx Installation Guide • |
|