Finisar AN-2030 specifications Bit Name Description

Page 24

 

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers

 

F i n i s a r

 

Real Time Diagnostic Registers

 

 

 

 

 

 

TABLE 3.17: A/D Values and Status Bits (2 Wire Address A2h)

 

 

 

 

 

 

 

 

 

Byte

Bit

Name

Description

 

 

 

 

 

 

 

 

 

 

 

 

Converted analog values. Calibrated 16 bit data.

 

 

 

 

96

All

Temperature MSB

Internally measured module temperature.

 

 

 

97

All

Temperature LSB

 

 

 

 

 

98

All

Vcc MSB

Internally measured supply voltage in transceiver.

 

 

99

All

Vcc LSB

 

 

 

 

 

100

All

TX Bias MSB

Internally measured TX Bias Current.

 

 

 

 

101

All

TX Bias LSB

 

 

 

 

 

102

All

TX Power MSB

Measured TX output power.

 

 

 

 

103

All

TX Power LSB

 

 

 

 

 

104

All

RX Power MSB

Measured RX input power.

 

 

 

 

105

All

RX Power LSB

 

 

 

 

 

106

All

Reserved MSB

Reserved for 1st future definition of digitized analog input

 

 

107

All

Reserved LSB

Reserved for 1st future definition of digitized analog input

 

 

108

All

Reserved MSB

Reserved for 2nd future definition of digitized analog input

 

 

109

All

Reserved LSB

Reserved for 2nd future definition of digitized analog input

 

 

 

 

 

 

 

 

Optional Status/Control Bits

 

 

 

 

 

110

7

TX Disable State

Digital state of the TX Disable Input

Pin.

Updated within

 

 

 

 

 

100msec of change on pin. This function is implemented in

 

 

 

 

 

all Finisar transceivers with digital diagnostic capability.

 

 

110

6

Soft TX Disable

Read/write bit that allows software disable of laser. Writing

 

 

 

 

 

‘1’ disables laser. Turn on/off time is 100 msec max from

 

 

 

 

 

acknowledgement of serial byte transmission. This bit is

 

 

 

 

 

“OR”d with the hard TX_DISABLE pin value. Note, per SFP

 

 

 

 

 

MSA TX_DISABLE pin is default enabled unless pulled low

 

 

 

 

 

by hardware. If Soft TX Disable is not implemented, the

 

 

 

 

 

transceiver ignores the value of this bit. Default power up

 

 

 

 

 

value is 0. This function is not implemented in Finisar

 

 

 

 

 

transceivers

 

 

 

 

110

5

Reserved

 

 

 

 

 

110

4

RX Rate Select State

Digital state of the SFP RX Rate Select Input Pin. Updated

 

 

 

 

 

within 100msec of change on pin. This function is not

 

 

 

 

 

implemented in Finisar transceivers.

 

 

 

 

110

3

Soft RX Rate Select

Read/write bit that allows software RX rate select. Writing ‘1’

 

 

 

 

 

selects full bandwidth operation. This bit is “OR’d with the

 

 

 

 

 

hard RX RATE_SELECT pin value.

Enable/disable time is

 

 

 

 

 

100msec max from acknowledgement of serial byte

 

 

 

 

 

transmission. Soft RX rate select does not meet the

 

 

 

 

 

autonegotiation requirements specified in FC-FS. Default at

 

 

 

 

 

power up is zero. If Soft RX Rate Select is not implemented,

 

 

 

 

 

the transceiver ignores the value of this bit. This function is

 

 

 

 

 

not implemented in Finisar transceivers.

 

 

 

110

2

TX Fault

Digital state of the TX Fault Output

Pin.

Updated within

 

 

 

 

 

100msec of change on pin. This function is not implemented

 

 

 

 

 

in Finisar transceivers.

 

 

 

9/26/02 Revision D

Page 24

Image 24
Contents Scope and Overview 35 2. Applicable DocumentsEnhanced Digital Diagnostic Interface Definition Overview Password Entry 8 bytes Specific Data Field DescriptionsCal Constants Bytes Control Functions 8 bytesSerial ID Data Fields Address A0 DataName Bytes Description of Field Address Connector IdentifierIdentifier values Extended IdentifierConnector values Description of connectorTransceiver Transceiver codes4a Sonet Reach Specifiers EncodingSpeed Reach Specifier bit Description Code Description of encoding mechanismBR, nominal Length 9μ-kmLength 9μ Length 50μLength Copper Vendor nameDwdm Channel Spacing Vendor OUIVendor Rev Laser WavelengthDwdm Wavelength Fraction Options Option valuesBR, max 13 BR, minDiagnostic Monitoring Type Date CodeData Description of field Address N i s a r Enhanced Options 10 I/O Timing for Soft Control & Status Functions SFF-8472 Compliance11 SFF-8472 Compliance Diagnostics 12 Bit weights C for temperature reporting registers 13 Digital temperature format TemperatureN i s a r Alarm and Warning Thresholds 14 Alarm and Warning Thresholds 2-Wire Address A2hN i s a r 16a Unsigned fixed-point binary format for slopes 16b Format for offsets16c IEEE-754 Single-Precision Floating Point Number Format 16d Example of Floating Point RepresentationBit Name Description Alarm and Warning Flags LOS18 Alarm and Warning Flag Bits 2-Wire Address A2h 19 Password Addresses 2-Wire Address A2h 20 User Eeprom 2-Wire Address A2hByte Bit Name Description Address # Bytes Name DescriptionWire Interface Operation Ddtc Electrical Interface Definition OverviewN i s a r Current Address Read Detailed 2 -Wire Serial Port Operation N i s a r Wire Protocol Data Transfer Protocol DC Electrical Characteristics Vcc = 3.15V toFor More Information