| F i n i s a r |
| ||||
|
| Table 3.18: Alarm and Warning Flag Bits | ||||
|
|
|
|
|
|
|
| Reserved Optional Alarm and Warning Flag Bits |
|
| |||
| 112 | 7 | Temp High Alarm | Set when internal temperature exceeds high alarm level. | ||
| 112 | 6 | Temp Low Alarm | Set when internal temperature is below low alarm level. | ||
| 112 | 5 | Vcc High Alarm | Set when internal supply voltage exceeds high alarm level. | ||
| 112 | 4 | Vcc Low Alarm | Set when internal supply voltage is below low alarm level. | ||
| 112 | 3 | TX Bias High Alarm | Set when TX Bias current exceeds high alarm level. | ||
| 112 | 2 | TX Bias Low Alarm | Set when TX Bias current is below low alarm level. | ||
| 112 | 1 | TX Power High Alarm | Set when TX output power exceeds high alarm level. | ||
| 112 | 0 | TX Power Low Alarm | Set when TX output power is below low alarm level. | ||
| 113 | 7 | RX Power High Alarm | Set when Received Power exceeds high alarm level. | ||
| 113 | 6 | RX Power Low Alarm | Set when Received Power is below low alarm level. | ||
| 113 | 5 | Reserved Alarm |
|
|
|
| 113 | 4 | Reserved Alarm |
|
|
|
| 113 | 3 | Reserved Alarm |
|
|
|
| 113 | 2 | Reserved Alarm |
|
|
|
| 113 | 1 | Reserved Alarm |
|
|
|
| 113 | 0 | Reserved Alarm |
|
|
|
| 114 | All | Reserved |
|
|
|
| 115 | All | Reserved |
|
|
|
| 116 | 7 | Temp High Warning | Set when internal temperature exceeds high warning level. | ||
| 116 | 6 | Temp Low Warning | Set when internal temperature is below low warning level. | ||
| 116 | 5 | Vcc High Warning | Set when internal supply voltage exceeds high warning level. | ||
| 116 | 4 | Vcc Low Warning | Set when internal supply voltage is below low warning level. | ||
| 116 | 3 | TX Bias High Warning | Set when TX Bias current exceeds high warning level. | ||
| 116 | 2 | TX Bias Low Warning | Set when TX Bias current is below low warning level. | ||
| 116 | 1 | TX Power High Warning | Set when TX output power exceeds high warning level. | ||
| 116 | 0 | TX Power Low Warning | Set when TX output power is below low warning level. | ||
| 117 | 7 | RX Power High Warning | Set when Received Power exceeds high warning level. | ||
| 117 | 6 | RX Power Low Warning | Set when Received Power is below low warning level. | ||
| 117 | 5 | Reserved Warning |
|
|
|
| 117 | 4 | Reserved Warning |
|
|
|
| 117 | 3 | Reserved Warning |
|
|
|
| 117 | 2 | Reserved Warning |
|
|
|
| 117 | 1 | Reserved Warning |
|
|
|
| 117 | 0 | Reserved Warning |
|
|
|
| 118 | All | Reserved |
|
|
|
| 119 | All | Reserved |
|
|
|
9/26/02 Revision D | Page 26 |