F i n i s a r |
1
23. Enhanced Digital Diagnostic Interface Definition
3
4Overview
5
6 The enhanced digital diagnostic interface is a superset of the
7defined in the SFP MSA document dated September 14, 2000. The
8definitions, hardware, and timing are clearly defined there, as well as in Section 4
9below. This section describes an extension to the memory map defined in the SFP
10MSA. The enhanced interface uses the two wire serial bus address 1010001X (A2h) to
11provide diagnostic information about the module’s present operating conditions. A
12memory map is shown in Figure 3.1 below.
13
14The transceiver generates this diagnostic data by digitization of internal analog signals.
15Calibration and alarm threshold data is written during device manufacture.
16
17In addition to generating digital readings of internal analog values, the device generates
18various status bits based on comparison between current values and
19limits.