Finisar AN-2030 specifications DC Electrical Characteristics, Vcc = 3.15V to

Page 34

 

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers

 

 

F i n i s a r

 

 

DC ELECTRICAL CHARACTERISTICS

 

 

 

( Vcc = 3.15V to 3.60V)

 

 

 

 

 

 

 

 

 

 

 

 

 

PARAMETER

SYMBOL

CONDITION

MIN

TYP

 

MAX

UNITS

 

NOTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Leakage (SDA,

ILI

 

-1

 

+1

μA

2

 

 

 

 

 

 

 

 

 

SCL)

 

 

 

 

 

 

 

 

 

 

 

 

Input Logic 1 (SDA,

VIH

 

0.7Vcc

 

 

Vcc+0.5

V

1

 

 

 

SCL)

 

 

 

 

 

 

 

 

 

 

 

 

Input Logic 0 (SDA,

VIL

 

GND-0.5

 

 

0.3Vcc

V

1

 

 

 

SCL)

 

 

 

 

 

 

 

 

 

 

 

 

Low Level Output

IOL1

0.4V

3

 

 

 

mA

1

 

 

 

Current (SDA)

IOL2

0.6V

6

 

 

 

mA

1

 

 

 

 

 

 

 

 

 

 

AC ELECTRICAL CHARACTERISTICS

 

 

 

( Vcc = 3.15V to 3.60V)

 

 

 

 

 

 

 

 

 

 

 

 

 

PARAMETER

SYMBOL

CONDITION

MIN

TYP

 

MAX

UNITS

 

NOTES

 

 

SCL clock frequency

fSCL

 

0

 

 

400

kHz

 

*,3

 

 

 

 

 

0

 

 

100

 

 

**

 

 

Bus free time between

tBUF

 

1.3

 

 

 

μs

 

*,3

 

 

STOP and START

 

 

4.7

 

 

 

 

 

**

 

 

condition

 

 

 

 

 

 

 

 

 

 

 

 

Hold time (repeated)

tHD:STA

 

0.6

 

 

 

μs

 

*,3,4

 

 

START condition

 

 

4.0

 

 

 

 

 

**

 

 

Low period of SCL

tLOW

 

1.3

 

 

 

μs

 

*,3

 

 

clock

 

 

4.7

 

 

 

 

 

**

 

 

High period of SCL

tHIGH

 

0.6

 

 

 

μs

 

*,3

 

 

clock

 

 

4.0

 

 

 

 

 

**

 

 

Data hold time

tHD:DAT

 

0

 

 

0.9

μs

 

*,3,5,6

 

 

 

 

 

0

 

 

 

 

 

**

 

 

Data set-up time

tSU:DAT

 

100

 

 

 

ns

 

*,3

 

 

 

 

 

250

 

 

 

 

 

**

 

 

Start set-up time

tSU:STA

 

0.6

 

 

 

μs

 

*,3

 

 

 

 

 

4.7

 

 

 

 

 

**

 

 

Rise time of both SDA

tR

 

20+0.1CB

 

 

300

ns

 

*

 

 

and SCL signals

 

 

 

 

 

1000

 

 

**

 

 

Fall time of both SDA

tF

 

20+0.1CB

 

 

300

ns

 

*

 

 

and SCL signals

 

 

 

 

 

300

 

 

**

 

 

Set-up time for STOP

tSU:STO

 

0.6

 

 

 

μs

 

*

 

 

condition

 

 

4.0

 

 

 

 

 

**

 

 

Capacitive load for

CB

 

 

 

 

400

pF

 

 

 

 

 

each bus line

 

 

 

 

 

 

 

 

 

 

 

 

EEPROM write time

TW

 

 

10

 

 

ms

 

 

 

 

*Fast mode

**Standard mode

Notes

1.All voltages are referenced to ground.

2.Input levels equal either Vcc or GND.

3.The output must be configured to source.

4.The output must be configured to have pull-up resistance enabled.

5.This is the time for one comparison. The cycle is multiplied by 3.

6.This parameter is measured with maximum output current.

9/26/02 Revision D

Page 34

Image 34
Contents Scope and Overview 35 2. Applicable DocumentsEnhanced Digital Diagnostic Interface Definition Overview Cal Constants Bytes Password Entry 8 bytesSpecific Data Field Descriptions Control Functions 8 bytesData Serial ID Data Fields Address A0Name Bytes Description of Field Address Identifier values ConnectorIdentifier Extended IdentifierConnector values Description of connectorTransceiver Transceiver codesSpeed Reach Specifier bit Description 4a Sonet Reach SpecifiersEncoding Code Description of encoding mechanismLength 9μ BR, nominalLength 9μ-km Length 50μDwdm Channel Spacing Length CopperVendor name Vendor OUILaser Wavelength Vendor RevDwdm Wavelength Fraction BR, max OptionsOption values 13 BR, minDate Code Diagnostic Monitoring TypeData Description of field Address N i s a r Enhanced Options SFF-8472 Compliance 10 I/O Timing for Soft Control & Status Functions11 SFF-8472 Compliance Diagnostics 12 Bit weights C for temperature reporting registers 13 Digital temperature format TemperatureN i s a r Alarm and Warning Thresholds 14 Alarm and Warning Thresholds 2-Wire Address A2hN i s a r 16a Unsigned fixed-point binary format for slopes 16b Format for offsets16c IEEE-754 Single-Precision Floating Point Number Format 16d Example of Floating Point RepresentationBit Name Description Alarm and Warning Flags LOS18 Alarm and Warning Flag Bits 2-Wire Address A2h Byte Bit Name Description 19 Password Addresses 2-Wire Address A2h20 User Eeprom 2-Wire Address A2h Address # Bytes Name DescriptionWire Interface Operation Ddtc Electrical Interface Definition OverviewN i s a r Current Address Read Detailed 2 -Wire Serial Port Operation N i s a r Wire Protocol Data Transfer Protocol DC Electrical Characteristics Vcc = 3.15V toFor More Information