Finisar AN-2030 Serial ID Data Fields Address A0, Name Bytes Description of Field Address

Page 4

 

AN-2030: Digital Diagnostic Monitoring Interface for Optical Transceivers

F i n i s a r

1

 

 

Table 3.1 Serial ID: Data Fields – Address A0

 

 

 

 

 

 

 

 

Data

Size

Name of

 

 

 

(Bytes)

Description of Field

 

 

Address

Field

 

 

 

 

 

BASE ID FIELDS

 

 

0

1

Identifier

Type of serial transceiver (see table 3.2)

 

 

1

1

Ext. Identifier

Extended identifier of type of serial transceiver

 

 

2

1

Connector

Code for connector type (see table 3.3)

 

 

3-10

8

Transceiver

Code for electronic compatibility or optical compatibility

 

 

 

 

(see table 3.4)

 

 

11

1

Encoding

Code for serial encoding algorithm (see table 3.5)

 

 

12

1

BR, Nominal

Nominal bit rate, units of 100 MBits/sec.

 

 

13

1

Reserved

 

 

 

14

1

Length(9µm) -

Link length supported for 9/125 µm fiber, units of km

 

 

 

km

 

 

 

15

1

Length (9µm)

Link length supported for 9/125 µm fiber, units of 100 m

 

16

1

Length (50µm)

Link length supported for 50/125 µm fiber, units of 10 m

 

17

1

Length (62.5µm)

Link length supported for 62.5/125 µm fiber, units of 10 m

 

18

1

Length (Copper)

Link length supported for copper, units of meters

 

 

19

1

Reserved

 

 

 

20-35

16

Vendor name

SFP vendor name (ASCII)

 

 

36

1

Reserved

DWDM channel spacing - DWDM modules only

 

 

37-39

3

Vendor OUI

SFP vendor IEEE company ID

 

 

40-55

16

Vendor PN

Part number provided by SFP vendor (ASCII)

 

 

56-59

4

Vendor rev

Revision level for part number provided by vendor (ASCII)

 

60-61

2

Wavelength

Laser wavelength

 

 

62

1

Reserved

DWDM wavelength fraction - DWDM modules only

 

63

1

CC_BASE

Check code for Base ID Fields (addresses 0 to 62)

 

 

 

 

EXTENDED ID FIELDS

 

 

64-65

2

Options

Indicates which optional transceiver signals are implemented

 

 

 

 

(see table 3.6)

 

 

66

1

BR, max

Upper bit rate margin, units of %

 

 

67

1

BR, min

Lower bit rate margin, units of %

 

 

68-83

16

Vendor SN

Serial number provided by vendor (ASCII)

 

 

84-91

8

Date code

Vendor’s manufacturing date code (see table 3.7)

 

 

92

1

Diagnostic

Indicates which type of diagnostic monitoring is implemented (if

 

 

 

Monitoring Type

any) in the transceiver (see Table 3.8)

 

 

93

1

Enhanced

Indicates which optional enhanced features are implemented (if any)

 

 

 

Options

in the transceiver (see Table 3.9)

 

 

94

1

SFF-8472

Indicates which revision of SFF-8472 the transceiver complies with.

 

 

 

Compliance

(see table 3.11)

 

 

95

1

CC_EXT

Check code for the Extended ID Fields (addresses 64 to 94)

 

 

 

 

VENDOR SPECIFIC ID FIELDS

 

 

96-127

32

Vendor Specific

Vendor Specific EEPROM

 

 

128-255

128

Reserved

Reserved for future use.

 

9/26/02 Revision D

Page 4

Image 4
Contents Scope and Overview 35 2. Applicable DocumentsEnhanced Digital Diagnostic Interface Definition Overview Password Entry 8 bytes Specific Data Field DescriptionsCal Constants Bytes Control Functions 8 bytesData Serial ID Data Fields Address A0Name Bytes Description of Field Address Connector IdentifierIdentifier values Extended IdentifierConnector values Description of connectorTransceiver Transceiver codes4a Sonet Reach Specifiers EncodingSpeed Reach Specifier bit Description Code Description of encoding mechanismBR, nominal Length 9μ-kmLength 9μ Length 50μLength Copper Vendor nameDwdm Channel Spacing Vendor OUILaser Wavelength Vendor RevDwdm Wavelength Fraction Options Option valuesBR, max 13 BR, minDate Code Diagnostic Monitoring TypeData Description of field Address N i s a r Enhanced Options SFF-8472 Compliance 10 I/O Timing for Soft Control & Status Functions11 SFF-8472 Compliance Diagnostics 12 Bit weights C for temperature reporting registers 13 Digital temperature format TemperatureN i s a r Alarm and Warning Thresholds 14 Alarm and Warning Thresholds 2-Wire Address A2hN i s a r 16a Unsigned fixed-point binary format for slopes 16b Format for offsets16c IEEE-754 Single-Precision Floating Point Number Format 16d Example of Floating Point RepresentationBit Name Description Alarm and Warning Flags LOS18 Alarm and Warning Flag Bits 2-Wire Address A2h 19 Password Addresses 2-Wire Address A2h 20 User Eeprom 2-Wire Address A2hByte Bit Name Description Address # Bytes Name DescriptionWire Interface Operation Ddtc Electrical Interface Definition OverviewN i s a r Current Address Read Detailed 2 -Wire Serial Port Operation N i s a r Wire Protocol Data Transfer Protocol DC Electrical Characteristics Vcc = 3.15V toFor More Information