Icom IC-M504 instruction manual Position and time programming

Page 27

Position and time programming

A distress call should include the ship’s position and time data. If no GPS is connected, your position and UTC (Univer- sal Time Coordinated) time should be input manually. They are included automatically when a GPS receiver (NMEA0183 ver. 2.0 or 3.01) is connected.

qPush [MENU] to enter the DSC menu.

wRotate [DIAL] to select “Position Input,” and push [DIAL•ENTER].

--DSC Menu--

Select Item

˘Position Input

Individual Call

Group Call

All Ships Call

Position Request

Position Report

eThe position information appears. Set your position (lati- tude and longitude) data by rotating [DIAL].

Push [16•9] or [CH/WX•DUAL•U/I/C] to move the cursor forward or backward, respectively.

Rotate [DIAL] to edit N; North latitude or S; South latitude when the cursor is on the ‘N’ or ‘S’ position, and W; West longitude or E; East longitude when the cursor is on the ‘W’ or ‘E’ position.

Push [CLR] for 1 sec. to clear the latitude/longitude data.

Push [CLR] to cancel and return to the DSC menu.

DSC OPERATION 6

--DSC Menu--

Input Position

Latitude

__°__.___N Null

Longitude

__°__.___W Null

<CLR 1sec˘Null Data>

<CLR˘Exit / ENT˘OK>

6

 

rAfter setting the position data, push [DIAL•ENTER] to set the current UTC time. Set the current UTC time by rotating [DIAL], then push [DIAL•ENTER].

Push [16•9] or [CH/WX•DUAL•U/I/C] to move the cursor forward or backward, respectively.

Push [CLR] for 1 sec. to clear the UTC time data.

Push [CLR] to cancel and return to the DSC menu.

--DSC Menu--

Input UTC Time

__:__Null

<CLR 1sec˘Null Data>

<CLR˘Exit / ENT˘OK>

tPush [CLR] or rotate [DIAL] to select “Exit,” push [DIAL•ENTER].

Returns to the DSC menu.

Repeat again to return to the normal operation condition.

Manually programmed position data will be held for 23.5 hours only.

21

Image 27
Contents IM504 Personal injury, fire or electric shock Word DefinitionMay occur Equipment damage may occurCase of Emergency Iii Determining MPE RadiusTable of Contents Precautions OPERATOR’S License Operating RulesRadio license for boaters U.S.A. only Ship Station LicenseFront panel Panel Description2TRANSMIT Power KEY H/L Function display 0TIME Zone Indicator1POSITION Indicator 2SCAN IndicatorMicrophone Channel 9 Call channel Basic OperationChannel selection ChannelRotate Dial to select a channel S.A., international and Canadian channelsWeather channels C to change the channel group, if necessaryReceiving and transmitting Call channel programming While pushing and holdingPush CH/WXDUAL Select the desired charac Channel commentsMicrophone Lock function Display backlightOptional voice scrambler operation Activating the scrambler Programming scrambler codesDialenter Normal Scan Scan OperationScan types Priority ScanSetting TAG channels Clearing or setting all tagged channelsStarting a scan DUALWATCH/TRI-WATCH Simulation DUALWATCH/TRI-WATCHDescription OperationRotate Dial to set the specific 9-digit Mmsi code DSC OperationMmsi code programming Rotate Dial to select Mmsi Check, push DialenterCheck the 9-digit Mmsi DSC self ID code Mmsi code checkRotate Dial to set the individual ID and ID name DSC address IDProgramming Individual ID Rotate Dial to select AddINDV ID, push DialenterDeleting Individual ID Rotate Dial to select Delindv ID, push DialenterRotate Dial to select the desired ID name for deleting Programming Group ID Rotate Dial to select AddGroup ID, push DialenterRotate Dial to set the group ID and ID name Rotate Dial to select DELGroup ID, push Dialenter Deleting Group IDPosition and time programming GPS information indication Position and time indicationDistress call Simple callAfter 2 sec. Wait ACK Regular call Distress alert contains defaultPush Distress for 5 sec. to transmit the distress call Transmitting an individual call Transmitting DSC callsPush Dialenter to transmit the individual call Transmitting an individual acknowledgement Transmitting a group call Push Dialenter to transmit the group call Transmitting an all ships call Rotate Dial to select the desired category, push DialenterPush Dialenter to transmit the all ships call Transmitting a position request call Push Dialenter to transmit the position request call Transmitting a position report call Push Dialenter to transmit the position report call Push Dialenter to transmit the polling request call Transmitting a polling request callTransmitting a position request reply call Your position data is transmitted, when Dialenter is pushed Transmitting a position report reply call Transmitting a polling request reply call Receiving a distress relay call Receiving DSC callsReceiving a distress call Receiving a distress acknowledgementReceiving an individual call Receiving a group callReceiving an all ships call Receiving a geographical area call Receiving a position request callReceiving a position report call Receiving a polling request reply call Receiving a polling request callReceiving a position request reply call Receiving a position report reply callRotate Dial to scroll the message Received messagesDistress message Rotate Dial to select Distress, push DialenterRotate Dial to select Other, push Dialenter Other messagesDSC Set mode No offset time defaultRotate Dial to select Offset Time, push Dialenter Automatic acknowledgement Rotate Dial to select Auto ACK, pushPush Dialenter to set the condition Rotate Dial to select Nmea Output, push Dialenter Nmea OutputOther Functions Intercom operationHM-162 listener RX Speaker function Push Hailrx to enter hailer mode Hailer operationTo return to normal operation, push CLR or Hailrx Sail Automatic foghorn functionUnderway StopRotate Dial to adjust the foghorn level, push Dialenter Tion is interrupted with an automatic return to the transIng DSC calls.’ p Scan resume timer SET ModeSet mode programming Set mode itemsLCD contrast Weather alertDual/Tri-watch Beep toneScrambler code Radio powerAutomatic foghorn frequency Scrambler typeConnections and Maintenance 0DC Power ConnectorConnections Fuse replacement Supplied accessoriesAntenna Mounting the transceiver Using the supplied mounting bracketMB-75 installation Tighten the end bolts on the clamps rotate clockwise soThat the clamps press firmly against the inside UT-112/UT-98 installation Return the cables and screws to the original position HM-162/HM-157 installationHM-162 HM-157 Completed installation should look like thisHM-162 HM-157Gasket Mm 131⁄32˝ Nut Cap Problem Possible Cause Solution TroubleshootingTransmitter Specifications and OptionsSpecifications General Receiver20 feet microphone extension cable for optional HM DimensionsOptions For mounting the transceiver to a panelTransmit Receive Channel ListTemplate R12 MaxUnit mm inch Cut here Page Memo Kamiminami, Hirano-ku, Osaka 547-0003, Japan