Technical Manuals Online! -
SUMMARY OF AUDIBLE NOTIFICATION
(ALPHA DISPLAY KEYPADS)
SOUND | CAUSE | DISPLAY |
LOUD, INTERRUPTED* | FIRE ALARM | FIRE is displayed; descriptor of zone in alarm is displayed. |
Keypad & External |
|
|
LOUD, CONTINUOUS* | BURGLARY/AUDIBLE | ALARM is displayed; descriptor of zone in alarm is also displayed. |
Keypad & External | EMERGENCY ALARM |
|
ONE SHORT BEEP | a. SYSTEM DISARM | a. DISARMED/READY TO ARM is displayed. |
(not repeated) | b. SYSTEM ARMING ATTEMPT | b. The number and descriptor of the open protection zone is displayed. |
Keypad only | WITH AN OPEN ZONE. |
|
| c. BYPASS VERIFY | c. Numbers and descriptors of the bypassed protection zones are displayed |
|
| (One beep is heard for each zone displayed). Subsequently, the following is |
|
| displayed: DISARMED BYPASS Ready to Arm |
ONE SHORT BEEP | SYSTEM IS IN TEST MODE | Opened Zone identifications will appear. |
(once every 15 seconds) |
|
|
Keypad only |
|
|
ONE BEEP every 60 sec. | LOW BATTERY AT A TRANSMITTER | LO BAT displayed with description of transmitter. |
Keypad only |
|
|
TWO SHORT BEEPS | ARM AWAY OR MAXIMUM | ARMED AWAY or ARMED MAXIMUM is displayed. Red ARMED indicator is |
Keypad only |
| lit. |
THREE SHORT BEEPS | a. ARM STAY OR INSTANT | a. ARMED STAY ZONE BYPASSED or ARMED INSTANT ZONE BYPASSED |
Keypad only |
| is displayed. Red ARMED indicator is lit. |
| b. ZONE OPENED WHILE SYSTEM | b. CHIME displayed, descriptor of open protection zone will be displayed if the |
| IS IN CHIME MODE. | [✱] key is pressed. |
| c. ENTRY WARNING** | c. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. |
RAPID BEEPING | a. TROUBLE | a. CHECK displayed. Descriptor of troubled protection zone is displayed. |
Keypad only | b. AC POWER LOSS ALERT*** | b. AC LOSS displayed (may alternate with other displays that may be present). |
| c. MEMORY OF ALARM | c. FIRE or ALARM is displayed; descriptor of zone in alarm is displayed. |
SLOW BEEPING | a. ENTRY DELAY WARNING** | a. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the |
Keypad only |
| delay time without disarming causes alarm. |
| b. EXIT DELAY WARNING | b. ARMED AWAY or ARMED MAXIMUM is displayed along with You May |
| (if programmed) | Exit Now |
*If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
**Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.
***Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).
– 48 –