First Alert FA1220CV technical manual 0000

Page 8

Technical

ABOUT THE KEYPADS

Fixed-Word Keypad Displays

Manuals Online!

AWAY: All burglary zones, interior & perimeter, are armed.

STAY: Perimeter burglary zones, such as windows & doors, are armed. Interior zones are bypassed.

INSTANT: Perimeter burglary zones are armed and entry delay is turned off. Interior zones are bypassed.

 

 

 

 

 

0000

AWAY

NO AC

 

AWAY

 

 

NO AC

 

BYPASS

 

 

BYPASS

NOTNOT READYREADY

 

 

 

STAY

CHIME BAT

ALARMALARM STAY

CHIME BAT

FIREFIRE CHECKCHECKINSTANTINSTANT

- http://www.tech-man.com

MAXIMUM:

All burglary zones, interior & perimeter, are armed, and entry delay is turned off.

BYPASS:

One or more burglary protection zones have been bypassed.

NOT READY:

Appears when burglary portion of the system is not ready for arming (due to open protection zones).

READY:

The burglary system is ready to be armed.

NO AC:

Appears when AC power has been cut off. System is operating on backup battery power.

AC:

Appears when AC power is present.

CHIME:

Appears when the CHIME feature is activated.

BAT:

Low battery condition in a wireless sensor (if ID number displayed) or low system battery (if no ID

 

number displayed).

ALARM: Appears when an intrusion has been detected and the system is armed (also appears during a fire

 

alarm or audible emergency alarm). Accompanied by the protection zone ID in alarm.

CHECK:

Appears when a malfunction is discovered in the system at any time or if a fault is detected in a FIRE

 

zone at any time or in a DAY/NIGHT burglary zone during a disarmed period. Accompanied by a

 

display of zone number in trouble. This also appears if the cover of certain wireless transmitters are

 

removed.

FIRE:

Appears when a fire alarm is present. Accompanied by a display of the zone in alarm.

– 8 –

Image 8
Contents Users Guide Table of Contents System Overview General Partitioned System ZonesArming Features For Each Arming Mode System Overview System Overview Alpha Keypad Fixed-Word Keypad About the KeypadsGeneral 0000 Online Functions of the Keypad OFFTechnical Manuals Online Partition ENTRY/EXIT DelaysGeneral Information Checking for Open Zones Using Ready KeyTo show faulted zones Displaying ALL Zone Descriptors Using Bypass Key Bypassing Protection ZonesTo bypass zones, the system must be disarmed first Enter your security code and pressDisplaying Bypassed Zones To use the Quick Bypass featureQuick Bypass Using Stay key Arming Perimeter onlyWith Entry Delay OFF Using Instant KeyUsing Away Key Arming ALL ProtectionUsing Maximum Key To disarm the system and silence burglary or fire alarms Disarming and Silencing AlarmsUsing the 1 OFF Key Memory of Alarm Using the Keyswitch GeneralChime Mode Using KeyViewing Central Station Messages MESSAGE. Press For 5 SecsKeys Zone Function Panic KeysActive Panic Functions Security Codes & Authority Levels InformationDuress Code Quick ArmingSecurity Codes & Authority Levels General Rules on Authority LevelsChanges To Exit User EditTo Add a User Enter Master or Manager code and pressLimited Use User #84 Command To Add a UserTo Change a Users Code To Delete a UserAccessing Other Partitions To Goto another partition using an alpha keypadSpeed Key Macros General Information Defining ExecutingUsing #70 Relay Menu Mode FA1220CV Event Logging Procedures Select the partitionFA1220CV Event Logging Procedures To Exit the Event Log Press at any timeTesting the System Using Test KeyTesting Your SystemTrouble Conditions Typical Check DisplaysServicing Information Alarm Silencing a FireSmoke Detectors for Minimum Protection Steps to Safety Emergency EvacuationMaintaining Your System Maintaining Your System Quick Guide to FA1220CV System Functions Quick Guide to FA1220CV System Functions Summary of Audible Notification Glossary Federal Communications Commission FCC Part 15 Statement UL Notice This is a Grade a systemFederal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Limitations of this Alarm System Owners Insurance Premium Credit Request Owners Insurance Premium Credit Request ONE Year Limited Warranty Page Page ÀN7003-1V2ä