Kenmore 116.38412 owner manual Cleaning the unit, Agitator does not turn

Page 22

Review this chart to find do-it-yourself solutions for minor performance problems. Any ser- vice needed, other than those described in this owner's manual, should be performed by an authorized service representative.

_r

cleaning the unit.

.-Failuretodo_ so could result in electrical shock or personal injury.

Cleaner won'trun.

Poor Job of dirt pick-up.

1.Unplugged at wall outlet.

2.Tripped circuitbreaker/blown fuse at household service panel.

3, On/off switch not turned on.

1, Full or clogged dust bag

2.Wrong pile height setting,

3.Worn brush,

4o Clogged nozzle or dirt tube,

5.Clogged hose.

6.Hole in hose.

7.Broken/misplaced belt.

8.Hose not Inserted fully

9.Motor protection system activated.

I0, Dlrty filters_

Io Plug in firmly, push on/off switch to

On.

2o Reset circuit breaker or replace fuse.

3.Push on/off switch to om

IIChange bsg, (page 13).

2. Adjust setting, (page 8).

3, Replace brush, (page 21)o

4.Clean nozzle area, (page 19).

5, Check for clogs, (page 19).

6.Replacshose,

7.Replace/f'Lbelt,(page17),

8.Insert hose fully, (page 9).

9.Check for ciogs, (page 19).

tO, Clean filters, (page 14),

Cleaner picks upI. Wrong pile height setting. moveable rugs or

pushes too hard.

1, Adjust setting, (page 7)°

Light won'twork.

Agitator does not turn.

Performance Indicator, some models, Is red.

1.Burned out light bulb.

1.Broken belt.

2.Bare floor selector in bare floor setting.

3.Belt installed incorrectly.

I.Full or clogged dust bag°

2.Dirty filters.

3.Clogged airflow passage - dirt tube, nozzle, hose,

4.Certain attachment toots,

1. Change fightbulb, (page 20).

1.Replace belt, (page 16)o

2.Switch selector to the carpet setting, (page 7),

3.Check BELT CHANGING AND BRUSH CLEANING, (page 17).

1.Change bag, (page 13)o

2.Clean filters, (page 14).

3.Clear clog from airflow passage. (page 19).

4.Should return to normal when tool is removed.

Air flow restricted

1.

Attachment

use restricts

with attachment usa.

 

air flow.

 

Sound changes.

2.

New carpet fuzz clogged air path°

Excessive

noise as

1.

Bert rubbing

on carpet/bare floor

vacuum Is

shut off.

 

selector shaft°

1.Check ATTACHMENTS. (page 8).

2.Check CLOG REMOVAL and clean hose, (page 19)o

1.Push selector all the way forward.

22

Image 22
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Part No, CO1ZAPYOOU00-4370481Safety Instructions Before UsingYour New VacuumKenmore Vacuum Cleaner Warranty Parts and FeaturesRead Do not putMotor Safety Filter BeltScrew with your Necessary to Adjust the handle slightlyBegin to tighten Fingers. It may beAround Do not operate the cleaner without the screw in placePower cord LockTo select a pile height setting To USE Attachments Handle MountedBody Mounted Telescoping Remove WandPressed wand Snap into the appropriate storage location To Store AttachmentsTo USE Extension Hose Between ATTACHMENTFurniture* Cushions* Drapes* Stairs WallsMotor Protection To correct problemGuide either side or the front of the noz Using attachments Performance IndicatorGather the cord and wrap it loosely To Remove BAG To Replace BAGButton located on Button the top of the bag Motor Safety FilterCheck motor safety filter frequently and change when dirty Aside New bag Away from Opening that Fits on Dirt TubeDishwasher Damp Install whileNot operate without exhaust FilterTo Remove Belt UpwardTo Replace Belt Loop the end of the new belt on the brush assemblyAssembly Vacuum UseIncorrect Routing of Belt Belt RoutingCorrect Routing of Belt Secure It on Cleaning section Plate asRemove the base plate and agitatorSee To Check BrushElectrical Shock Or Personal Injury Hazard IllustrationCleaning the unit Agitator does not turnCanada Www,sea rs.comAspiradora Pieza NOCO1ZAPY00U00-4370481 Impreso en EUALimpieza del exterior y de los accesorios o Lnstrucciones importantes deCuidado La aspiradora CepilloAdvertencia 20-40600 AIg.nosmodelos 20-40096Aspiradora Gire el No apriete demasiado el tornilloLade y hacia abajo para liberar el cord6n Algunos Modelos Apagado d Montado EN EL MangoMontado EN EL Cuerpo MangoTelesc6plco Para Operar EL Desliza DOR DE Control DETubo Deslfzadorde Tubo -..controldeTEl.AS CEPiLLO ParaMuebles Entre Coijines Cortlnas Escalones ParadesOrillas de alfombras Sistema DE Protection DE MotorPara corregir el pro. blema Consults el cua Dro Reconoci Indicador DE Rendimiento Guarde la aspira- dora bajo techo en unPapa Cambiar LA Bolsa Cublerta , de la bolsa l Filtro DE Seguridad DEL MotorFiltroEleclrostdtico Blancohacia arriba De la bolsaEn la ranu- Pestaa de CubiertaRanura de Posici6n de la Cubierta de la bo/saSegurldad AgitadorPlato Ia correa 18, sopoeSoporte del Ceplllo Unldaddel agltador Soporte del Ranura de La boquilla La boqutllaEJe de Ele del selector Ee del selectorde Eje de Plsos con y sinEnsemble Selector Oet ceplllq De plsos Con alfom Ublcecl6nde las TabsEncoja AspiradoraLimpieza Hasta suRemueva Remueva la bomTura, Despus De la plata de la base Para Cambiar EL CepilloCuando los cepillos Arandelas y los soportes det cepillo1o Estdesconectade Part Iy,!iiii!!iiElectronics Call for Nearest Sears Parts and Repair Center Wwwosears.com