Kenmore 153.32116, 153.32118 manual Display Shows Indicates

Page 23

DISPLAY SHOWS

 

INDICATES

UPPER ELEMENT

1.

Upper element

is not

CONNECT

 

functioning

 

FAU LT

 

 

 

LOWER ELEMENT

1.

Lower element

is not

CONNECT

 

functioning

 

FAU LT

 

 

 

HEAT PUMP

 

1.

Heat Pump compressor

is

CONNECT

 

 

not functioning.

 

 

FAU LT

 

 

 

 

 

 

 

FAN

 

 

1.

Heat Pump fan is not

 

CONNECT

 

 

functioning.

 

 

FAU LT

 

 

 

 

 

 

 

AMBIENT

TEMP

 

1.

Ambient

Temperature

 

SENSOR

SHORT

OR

 

Sensor

is not functioning.

 

OPEN OR AD ERROR

 

 

 

 

 

UPPER TEMP

 

1.

Upper Temperature

Sensor

SENSOR

SHORT

OR

 

is not functioning.

 

 

OPEN OR AD ERROR

 

 

 

 

 

LOWER

TEMP

 

1.

Lower Temperature

Sensor

SENSOR

SHORT

OR

 

is not functioning.

 

 

OPEN OR AD ERROR

 

 

 

 

 

DISCHARGE TEMP

1.

Discharge Temperature

 

SENSOR

SHORT OR

 

Sensor

is not functioning.

 

OPEN OR AD ERROR

 

 

 

 

 

COIL TEMP

 

1.

Coil Temperature Sensor

is

SENSOR

FAULT

 

 

not functioning.

 

 

OR AD ERROR

CORRECTIVE ACTION

1.Turn off power at the circuit breaker/fuse box and check for a loose connection at the element. For access directions

see "Element Removal/Replacement" section. If error persists proceed to the next step.

2.Replace non-functioning element. See "Element Removal/ Replacement" section.

1.Turn off power at the circuit breaker/fuse box and check for a loose connection at the element. For access directions see "Heating Element Replacement" section. If error

persists proceed to the next step.

2.Replace non-functioning element. See "Element Removal/ Replacement" section.

IMPORTANT: Using an element greater than 2000 watts in place of the lower element will damage the water heater.

1.Contact a qualified person to service the heat pump.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

1.Contact a qualified person to service the unit.

MAIN CIRCUIT BOARD FAU LT

HIGH TEMP

LOCKOUT

CONDENSATE

DRAIN

ALARM

(If Accessory Condensate Pump is Installed)

1.Main Circuit Board is not functioning.

1.Water temperature in unit has exceeded 190° F.

1.Condensate pump failure.

1.Contact a qualified person to service the unit.

1.See "High Temperature Shut-off System" section.

1.Check to see if accessory condensate pump is plugged in and has power. Also check circuit breaker/fuse box and GFCI (if used), if error persists proceed to the next step.

2.Check condensate pump outlet tube for blockage, if error persists proceed to the next step.

3.Check control wire connections to condensate pump. If error

persists proceed to the next step.

4.Replace accessory condensate pump. If error persists contact a Qualified Person.

LOW WATER

LEVEL ALARM

COMMUNICATION ERROR

ELECTRONIC POWER ANODE ERROR #0-9

(# CAN BE 0-9)

1.

Not enough water in the

1. Fill Completely - Open all hot water taps in home and

run

 

tank.

until water (uninterrrupted by air) flows from all open

hot

 

(Tank not full)

water taps.

 

1.No communication between 1. Contact a qualified person to service the unit. mainboard and user

interface board.

1.Indicates the power anode is 1. Contact a qualified person to service the unit. not operating properly

NOTE: The diagnostic codes listed above are the most common. If a diagnostic code not listed above is displayed, contact Sears Repair Services at 1-800-4-MY-HOME (1-800-469-4663).

23

Image 23
Contents Ienmore Elite Important Definitions Fire Hazard / Electric Shock Hazard Improper installation and use may result in property damageYear Limited Warranty on Water H Eater Safe Installation USE and Service General ThankYouforpurchasingSearswaterheaterProperly Installedandmaintained,itshouldgiveyouyearsoftroublefreeBasic Tools Additional Tools Needed When Sweat SolderingMaterials Needed Removing the Old Water Heater With water Facts to Consider About the LocationInsulation Blankets SeeClosed System Water Piping System Piping InstallationProperty Damage Hazard Condensate Drain Line InstallationValve and Pipe Insulation Explosion Hazard Temperature-Pressure Relief ValveFilling the Water Heater WiringConnecting the Condensate Pump Overflow Shut Off Switch Wiring DiagramCondensate Drain Line Post Installation ReviewWater Heater Location Water System PipingOperational Modes Before UsingTemperature Regulation Adjusting the User Interface ModuleSet temperature in Fahrenheit or Celsius Operating Mode DescriptionsDraining and Flushing Element Removal/ReplacementAir Filter Cleaning/Replacement Routine Preventive MaintenanceService Drain Valve Washer ReplacementOperational Conditions Thermal Expansion Tank SpecificationsStart Up Conditions AIR in HOT Water Faucets Display Shows Indicates Problem Installation Instructions section Kenmore Elite Hybrid Electric Heat Pump Water Heaters Page Call anytime, day or night U.S.A. and Canada Managemylife

153.32116, 153.32118 specifications

The Kenmore 153.32118 and 153.32116 are leading models in the realm of water heaters, designed to enhance efficiency and performance while maintaining user-friendliness. Both models cater to the modern consumer's needs for reliable hot water access in residential settings.

One of the standout features of the Kenmore 153.32118 and 153.32116 is their energy-efficient design. Equipped with advanced insulation technology, these heaters maximize heat retention, which minimizes energy loss and contributes to lower utility bills. The units operate on an efficient heating element that quickly raises water temperature, ensuring that users have hot water available whenever they need it.

Both models come with a user-friendly digital display that allows homeowners to easily adjust settings, monitor water temperature, and receive alerts about system performance. This intuitive interface enhances the overall user experience, making it simple for anyone to operate the heater without requiring extensive technical knowledge.

Safety is a top priority in the design of these water heaters. They are equipped with multiple safety features, such as a temperature control mechanism that prevents overheating and a pressure relief valve that mitigates risks associated with excessive pressure build-up. These safety measures ensure peace of mind for the user, knowing that the appliance is designed to operate safely within a home environment.

The Kenmore 153.32118 and 153.32116 models also boast a compact design, allowing them to fit seamlessly into various spaces, whether in a utility room, basement, or closet. The sleek appearance ensures that they can be incorporated into the home without disrupting the aesthetic flow of the environment.

Maintenance is made simple with these units, as they are designed to require minimal attention over time. The self-cleaning feature helps inhibit sediment buildup, which can affect efficiency and longevity. This technology not only extends the lifespan of the heaters but also ensures consistent performance over time.

In conclusion, the Kenmore 153.32118 and 153.32116 represent a blend of efficiency, safety, and modern technology. With their advanced features and user-friendly design, they meet the demands of today’s households for reliable hot water solutions while keeping energy consumption to a minimum. Whether for daily household needs or specialized tasks, these water heaters stand out as robust options in the market.