New ALE Features

To remove an address from the stack:

The radio automatically removes an address from the stack in the following cases:

When the operator calls a station registered in the caller stack, all stack calls containing that address are erased from the stack, regardless of whether the call was returned from within the stack or during an individual call.

The stack can contain up to ten addresses. When the stack is full and a new address comes in, the new address replaces the oldest address in the stack.

In addition, you can manually remove an address from the stack as follows:

1.Press STAK (F3).

2.Use the UP/DOWN keys to scroll to the required call.

3.Press ERAS (F2).

4.Press YES (F1) to confirm or, NO (F2) to cancel the deletion.

Disconnecting Calls

When you are in the link state, your radio can communicate with at least one other ALE station.

To disconnect an incoming call:

Press the ESC key. This disconnects the link and returns the radio to the mode used before the link was established.

MOTOROLA

END CALLING

When you disconnect a link, you can instruct the other station(s) to return to the working mode they were in before they entered the link state. This feature is called Home Acknowledge, and can be programmed. If Home Acknowledge is enabled:

In an individual link, each of the stations in the link can transmit the Home Acknowledgement to instruct the other stations to disconnect the link.

In a net/AnyCall link, the Home Acknowledgement can only be transmitted by the radio which initiated the call.

_________________________________________________________________________________________________ 23

Image 37
Contents MICOM-2ES/2RS/2TS ALE Page Commercial Warranty Standard Computer Software Copyrights MICOM-2ES/2RS/2TS ALE HF-SSB Transceiver Page General Safety Precautions Radio device is not authorized for general population This radio is intended for use in occupational/controlledConsumer or similar use Federal Communication Commission Regulations Communication Commission Regulations section Interference EMI if inadequately shielded, designed, or Driver SafetyOperational Warnings Table of Contents Viii Introduction Channel CH Menu Frequency Freq Menu Prog Menu Radio Parameters Programming Prog Menu ALE Parameters Programming ALE Addressing Method Selective CallingAddress and Call Types Use of @ Stuffing SymbolIndividual Station Address Group Addresses Net AddressesSpecial Addressing Modes Use of Wildcards ? ? ? Use of ? Wildcard SymbolAllCall Addresses Use of ? Wildcard SymbolSelf Addresses AnyCallsNull Address Inlink AddressUsing the MultiNet Feature Using the Caller Stack Using ALE Functions in the Channel ModeMessages Quick CallEnabling the ALE Mode Entering the ALE ModeTo enter the ALE mode ALE and Rx Only or Tx Only ChannelsALE NET ALE Mode OptionsInformation appearing in this section updates the ALE Receiving and Transmitting Calls in ALE ModeOperating instructions presented in previous publications ALE operating instructions appearing in this SupplementReceiving an individual call Receiving Calls in ALE ModeReceiving a net call Receiving an AllCallReceiving a sounding call Receiving an AnyCallReceiving a bidirectional handshake call To answer an incoming callAbcpack Function is not available when receiving an AllCallTo display LQA for the received call Link StateRPL MORE, F1 To replace the channel Replacing the Current Channel While in the Link StateTo view the calls in the stack Using the Caller StackTo return a call to a station registered in the stack AddressTo remove an address from the stack Disconnecting CallsTo disconnect an incoming call END CallingUsing the MON F4 key Transmitting Calls in ALE ModeSelecting the Desired Net To select a netTo transmit an individual call with MultiNet OFF Calls to an Individual StationTo transmit an individual call with MultiNet on Your radio switches to the Channel mode for the duration Channel mode. If the other station is in the Channel modeTo transmit on a specific channel Pressing Best F3 is the first scanned channel of the netContained a message Quick CallData exists To send a quick callTo use Autodial to send a call Using AutodialTo transmit an individual call with a message Sending MessagesAMD11 AMD Mess To send a message during a call link state To select a special call type Other Types of CallsOption Capabilities See Page … ALLANY GRPWild SelfTo send global AllCall using the Call function To send global AllCall using the ESC keyGL Allcall Link GL AllcallIf you decide to send a Global AllCall, press Glob F3 To send selective AllCallIf you decide to send a global AllCall, press Glob F3 or ? Link SL Allcall To transmit a net call Transmitting Net CallsCall NET Transmitting Group Calls Characters. Therefore, when an address is not an exactExplained on page 6, each ALE word must include Request is rejected and you will see for a few seconds AT To transmit a group callIf adding the station would cause To define or change a groupTotal length of the station addresses After pressing ADD F1 you will seeTransmitting AnyCalls DIR BUDIR BUD Call ANY To transmit an AnyCallALL Ending ALL ENDING59 ALL ENDING1You can press Stop F1 or ESC to abort the entire process Link ANYTo transmit a wildcard call Transmitting Wildcard CallsAT Least Call WildYou can also include the self address in a group call Transmitting a Self CallTo send a self-call MICOM-2 can also be programmed to automatically initiate Bidirectional HandshakeOptions Bdir LQABdir NET To execute a bidirectional handshake with a netChange the net, see To manually initiate sounding SoundingSond Sound OFF Do not enable the inlink function when communicating with a Using the Inlink FunctionAll the stations Radio that does not support the full ALE capabilitiesTransmitting ALE Calls in the Channel Mode Menu To enter the ALE Programming modeProg NET RCVDIR AMD Programming NetsYou can also edit, or prepare a new message, on-line OPT Auto StorName Memb Chan GET Eras Default ValuesSetting the Net Options Directory Parameters AMD Message ConfigurationExal Alrt ALE Options ConfigurationMlqa Qcal If the directory is full, new addresses will not be addedMNT Ilnk BdlkStoring ALE Parameters Auto Dial ParametersAMD Ilnk BdlkUsing the New Station Address Filter

MICOM-2ES/2RS/2TS ALE specifications

Motorola MICOM-2ES/2RS/2TS ALE is a sophisticated communication system designed for critical and emergency communication applications. The system is part of Motorola’s esteemed MICOM range, known for its ruggedness and reliability in challenging environments. ALE, or Automatic Link Establishment, is a crucial feature of the MICOM series, enabling efficient and automated establishment of radio links between devices, which is essential for operations where timely communication is a matter of urgency.

One of the main features of the MICOM-2 series is its robust ALE capabilities, allowing operators to automatically find the best frequency for communication based on current conditions. This dynamic frequency selection not only enhances the reliability of the communication link but also minimizes the possibility of interference from other signals, which can be critical in emergency situations.

The MICOM-2ES, 2RS, and 2TS models feature advanced digital signal processing technologies that optimize audio clarity and reception. This ensures that communication remains clear even in noisy environments, which is a pivotal factor in emergency response scenarios. With a digital signal processor onboard, the system is capable of filtering out unwanted noise and enhancing the quality of the transmitted audio.

These models support multiple modes of operation, including both simplex and duplex communications. Such versatility allows users to adapt the system to various communication needs, augmenting its effectiveness in a range of operation scenarios. Furthermore, the MICOM-2 series is compatible with various antenna configurations, enhancing the operational range and flexibility of the system.

User-friendliness is another hallmark of the MICOM-2ES/2RS/2TS ALE systems, as they feature an intuitive user interface that simplifies operation, allowing for quick and efficient communication in high-pressure situations. Emergency responders and military personnel benefit greatly from such ease of use, leading to faster response times and improved overall coordination.

Additionally, the robustness of the Motorola MICOM-2 series ensures that it can withstand extreme environmental conditions. The units are designed to operate in harsh weather and rugged terrains, making them ideal for outdoor usage in emergency or military applications. All these features combined make the Motorola MICOM-2ES/2RS/2TS ALE a reliable choice for organizations that require high-performance communication solutions in demanding conditions.