Motorola MICOM-2ES/2RS/2TS ALE manual Using Autodial, To use Autodial to send a call

Page 43

New ALE Features

Using Autodial

The Autodial feature lets you use a single digit to call a preprogrammed address. There are ten programmable Autodial addresses, where each can include a message.

See Auto Dial Parameters on page 61 for details on programming the Autodial list.

To use Autodial to send a call:

 

MOTOROLA

 

CALL

1. Press # on the keypad.

SELECT#_

If you do not select an auto-address within a few seconds, the display automatically reverts to the previous state.

Note

2.Press the desired preprogrammed Autodial number (0 to 9).

The programmed address is immediately displayed; if a message is preprogrammed, an exclamation sign will appear before the station name.

Press PAGE (F2) if you want to attach a message to the call or to replace/edit a preprogrammed attached message. See page 30.

MOTOROLA

CALL 1009

SEND PAGE CHAN MONs

If the Autodial number you enter is not programmed, the message NOT PROG will be displayed.

Note

3.Press CHAN (F3) if you want the call to be initiated on a specific channel. See page 30.

4.Press ENTER or SEND (F1) to start the call.

5.The radio now starts the link set up process. During this process, you will see TO alternating with the number of the channel on which the set up request is being sent (the channel may change, if the called station does not answer on the first channel(s)).

While the radio is initializing the link, you can press STOP (F1) or ESC to abort the entire process.

Note

_________________________________________________________________________________________________ 29

Image 43
Contents MICOM-2ES/2RS/2TS ALE Page Commercial Warranty Standard Computer Software Copyrights MICOM-2ES/2RS/2TS ALE HF-SSB Transceiver Page General Safety Precautions Radio device is not authorized for general population This radio is intended for use in occupational/controlledConsumer or similar use Federal Communication Commission Regulations Communication Commission Regulations section Interference EMI if inadequately shielded, designed, or Driver SafetyOperational Warnings Table of Contents Viii Introduction Channel CH Menu Frequency Freq Menu Prog Menu Radio Parameters Programming Prog Menu ALE Parameters Programming ALE Addressing Method Selective CallingAddress and Call Types Use of @ Stuffing SymbolIndividual Station Address Group Addresses Net AddressesSpecial Addressing Modes Use of Wildcards ? ? ? Use of ? Wildcard SymbolAllCall Addresses Use of ? Wildcard SymbolInlink Address AnyCallsSelf Addresses Null AddressUsing the MultiNet Feature Quick Call Using ALE Functions in the Channel ModeUsing the Caller Stack MessagesALE and Rx Only or Tx Only Channels Entering the ALE ModeEnabling the ALE Mode To enter the ALE modeALE NET ALE Mode OptionsALE operating instructions appearing in this Supplement Receiving and Transmitting Calls in ALE ModeInformation appearing in this section updates the ALE Operating instructions presented in previous publicationsReceiving an AllCall Receiving Calls in ALE ModeReceiving an individual call Receiving a net callTo answer an incoming call Receiving an AnyCallReceiving a sounding call Receiving a bidirectional handshake callLink State Function is not available when receiving an AllCallAbcpack To display LQA for the received callRPL MORE, F1 To replace the channel Replacing the Current Channel While in the Link StateAddress Using the Caller StackTo view the calls in the stack To return a call to a station registered in the stackEND Calling Disconnecting CallsTo remove an address from the stack To disconnect an incoming callTo select a net Transmitting Calls in ALE ModeUsing the MON F4 key Selecting the Desired NetTo transmit an individual call with MultiNet OFF Calls to an Individual StationTo transmit an individual call with MultiNet on Pressing Best F3 is the first scanned channel of the net Channel mode. If the other station is in the Channel modeYour radio switches to the Channel mode for the duration To transmit on a specific channelTo send a quick call Quick CallContained a message Data existsTo use Autodial to send a call Using AutodialTo transmit an individual call with a message Sending MessagesAMD11 AMD Mess To send a message during a call link state ALL Other Types of CallsTo select a special call type Option Capabilities See Page …Self GRPANY WildLink GL Allcall To send global AllCall using the ESC keyTo send global AllCall using the Call function GL AllcallIf you decide to send a Global AllCall, press Glob F3 To send selective AllCallIf you decide to send a global AllCall, press Glob F3 or ? Link SL Allcall To transmit a net call Transmitting Net CallsCall NET Transmitting Group Calls Characters. Therefore, when an address is not an exactExplained on page 6, each ALE word must include Request is rejected and you will see for a few seconds AT To transmit a group callAfter pressing ADD F1 you will see To define or change a groupIf adding the station would cause Total length of the station addressesTransmitting AnyCalls DIR BUDIR BUD Call ANY To transmit an AnyCallALL Ending Link ANY ALL ENDING1ALL ENDING59 You can press Stop F1 or ESC to abort the entire processTo transmit a wildcard call Transmitting Wildcard CallsAT Least Call WildYou can also include the self address in a group call Transmitting a Self CallTo send a self-call MICOM-2 can also be programmed to automatically initiate Bidirectional HandshakeOptions Bdir LQABdir NET To execute a bidirectional handshake with a netChange the net, see To manually initiate sounding SoundingSond Sound OFF Radio that does not support the full ALE capabilities Using the Inlink FunctionDo not enable the inlink function when communicating with a All the stationsTransmitting ALE Calls in the Channel Mode NET RCV To enter the ALE Programming modeMenu ProgOPT Auto Stor Programming NetsDIR AMD You can also edit, or prepare a new message, on-lineName Memb Chan GET Eras Default ValuesSetting the Net Options Directory Parameters AMD Message ConfigurationIf the directory is full, new addresses will not be added ALE Options ConfigurationExal Alrt Mlqa QcalMNT Ilnk BdlkIlnk Bdlk Auto Dial ParametersStoring ALE Parameters AMDUsing the New Station Address Filter

MICOM-2ES/2RS/2TS ALE specifications

Motorola MICOM-2ES/2RS/2TS ALE is a sophisticated communication system designed for critical and emergency communication applications. The system is part of Motorola’s esteemed MICOM range, known for its ruggedness and reliability in challenging environments. ALE, or Automatic Link Establishment, is a crucial feature of the MICOM series, enabling efficient and automated establishment of radio links between devices, which is essential for operations where timely communication is a matter of urgency.

One of the main features of the MICOM-2 series is its robust ALE capabilities, allowing operators to automatically find the best frequency for communication based on current conditions. This dynamic frequency selection not only enhances the reliability of the communication link but also minimizes the possibility of interference from other signals, which can be critical in emergency situations.

The MICOM-2ES, 2RS, and 2TS models feature advanced digital signal processing technologies that optimize audio clarity and reception. This ensures that communication remains clear even in noisy environments, which is a pivotal factor in emergency response scenarios. With a digital signal processor onboard, the system is capable of filtering out unwanted noise and enhancing the quality of the transmitted audio.

These models support multiple modes of operation, including both simplex and duplex communications. Such versatility allows users to adapt the system to various communication needs, augmenting its effectiveness in a range of operation scenarios. Furthermore, the MICOM-2 series is compatible with various antenna configurations, enhancing the operational range and flexibility of the system.

User-friendliness is another hallmark of the MICOM-2ES/2RS/2TS ALE systems, as they feature an intuitive user interface that simplifies operation, allowing for quick and efficient communication in high-pressure situations. Emergency responders and military personnel benefit greatly from such ease of use, leading to faster response times and improved overall coordination.

Additionally, the robustness of the Motorola MICOM-2 series ensures that it can withstand extreme environmental conditions. The units are designed to operate in harsh weather and rugged terrains, making them ideal for outdoor usage in emergency or military applications. All these features combined make the Motorola MICOM-2ES/2RS/2TS ALE a reliable choice for organizations that require high-performance communication solutions in demanding conditions.