MICOM-2ES/2RS/2TS ALE Supplement to Owner’s Guide

MNT MultiNet: enable/disable the scanning of multiple ALE nets. When enabled, this feature lets the radio communicate with stations in nets other than the currently selected net.

MxCH Maximum Scan Channels: when MultiNet is enabled, the time needed for scanning all the nets may be rather long. This parameter is used to adapt the duration of the calling signal to the number of scanned net, to ensure that communications are not disrupted.

You can use automatic selection, or select a specific value in the range of 0 to 59 seconds.

ANY AnyCall: enable/disable the sending of AnyCalls.

WILD Wildcard: enable/disable the sending wildcard calls.

AMD Automatic Message Display: enable/disable the sending of AMD messages.

ILNK

BDLK

Inlink: enable/disable the inlink facility, which enables notifying other call participants when each participant disconnects from the link. All participants must be programmed to use the same selection (either YES or NO).

Do not enable the inlink function when communicating with a radio that does not support the full ALE capabilities in accordance with MIL-STD-188-141B.

Bidirectional link: enable/disable the automatic setting up of a link on the best channel after a bidirectional handshake with an individual station.

The ALE options have the following factory-default values:

PTT Timeout

No timeout

Alert

Yes

External Alarm

Yes

Auto Address

No

Quick Call

Yes

Minimum LQA score

0

Accept Link Timeout

Yes

MNT

Yes

MxCH

Auto

ANY

Yes

WILD

Yes

60_________________________________________________________________________________________________

Image 74
Contents MICOM-2ES/2RS/2TS ALE Page Commercial Warranty Standard Computer Software Copyrights MICOM-2ES/2RS/2TS ALE HF-SSB Transceiver Page General Safety Precautions Consumer or similar use This radio is intended for use in occupational/controlledRadio device is not authorized for general population Federal Communication Commission Regulations Communication Commission Regulations section Driver Safety Interference EMI if inadequately shielded, designed, orOperational Warnings Table of Contents Viii Introduction Channel CH Menu Frequency Freq Menu Prog Menu Radio Parameters Programming Prog Menu ALE Parameters Programming Selective Calling ALE Addressing MethodIndividual Station Address Use of @ Stuffing SymbolAddress and Call Types Special Addressing Modes Use of Wildcards Net AddressesGroup Addresses Use of ? Wildcard Symbol ? ? ?Use of ? Wildcard Symbol AllCall AddressesNull Address AnyCallsSelf Addresses Inlink AddressUsing the MultiNet Feature Messages Using ALE Functions in the Channel ModeUsing the Caller Stack Quick CallTo enter the ALE mode Entering the ALE ModeEnabling the ALE Mode ALE and Rx Only or Tx Only ChannelsALE Mode Options ALE NETOperating instructions presented in previous publications Receiving and Transmitting Calls in ALE ModeInformation appearing in this section updates the ALE ALE operating instructions appearing in this SupplementReceiving a net call Receiving Calls in ALE ModeReceiving an individual call Receiving an AllCallReceiving a bidirectional handshake call Receiving an AnyCallReceiving a sounding call To answer an incoming callTo display LQA for the received call Function is not available when receiving an AllCallAbcpack Link StateRPL MORE, F1 Replacing the Current Channel While in the Link State To replace the channelTo return a call to a station registered in the stack Using the Caller StackTo view the calls in the stack AddressTo disconnect an incoming call Disconnecting CallsTo remove an address from the stack END CallingSelecting the Desired Net Transmitting Calls in ALE ModeUsing the MON F4 key To select a netCalls to an Individual Station To transmit an individual call with MultiNet OFFTo transmit an individual call with MultiNet on To transmit on a specific channel Channel mode. If the other station is in the Channel modeYour radio switches to the Channel mode for the duration Pressing Best F3 is the first scanned channel of the netData exists Quick CallContained a message To send a quick callUsing Autodial To use Autodial to send a callAMD11 AMD Mess Sending MessagesTo transmit an individual call with a message To send a message during a call link state Option Capabilities See Page … Other Types of CallsTo select a special call type ALLWild GRPANY SelfGL Allcall To send global AllCall using the ESC keyTo send global AllCall using the Call function Link GL AllcallIf you decide to send a global AllCall, press Glob F3 or ? To send selective AllCallIf you decide to send a Global AllCall, press Glob F3 Link SL Allcall Call NET Transmitting Net CallsTo transmit a net call Explained on page 6, each ALE word must include Characters. Therefore, when an address is not an exactTransmitting Group Calls To transmit a group call Request is rejected and you will see for a few seconds ATTotal length of the station addresses To define or change a groupIf adding the station would cause After pressing ADD F1 you will seeDIR BUD DIR BUTransmitting AnyCalls ALL Ending To transmit an AnyCallCall ANY You can press Stop F1 or ESC to abort the entire process ALL ENDING1ALL ENDING59 Link ANYTransmitting Wildcard Calls To transmit a wildcard callCall Wild AT LeastTo send a self-call Transmitting a Self CallYou can also include the self address in a group call Options Bidirectional HandshakeMICOM-2 can also be programmed to automatically initiate LQA BdirChange the net, see To execute a bidirectional handshake with a netBdir NET Sond Sound OFF SoundingTo manually initiate sounding All the stations Using the Inlink FunctionDo not enable the inlink function when communicating with a Radio that does not support the full ALE capabilitiesTransmitting ALE Calls in the Channel Mode Prog To enter the ALE Programming modeMenu NET RCVYou can also edit, or prepare a new message, on-line Programming NetsDIR AMD OPT Auto StorName Memb Chan Default Values GET ErasSetting the Net Options AMD Message Configuration Directory ParametersMlqa Qcal ALE Options ConfigurationExal Alrt If the directory is full, new addresses will not be addedIlnk Bdlk MNTAMD Auto Dial ParametersStoring ALE Parameters Ilnk BdlkUsing the New Station Address Filter

MICOM-2ES/2RS/2TS ALE specifications

Motorola MICOM-2ES/2RS/2TS ALE is a sophisticated communication system designed for critical and emergency communication applications. The system is part of Motorola’s esteemed MICOM range, known for its ruggedness and reliability in challenging environments. ALE, or Automatic Link Establishment, is a crucial feature of the MICOM series, enabling efficient and automated establishment of radio links between devices, which is essential for operations where timely communication is a matter of urgency.

One of the main features of the MICOM-2 series is its robust ALE capabilities, allowing operators to automatically find the best frequency for communication based on current conditions. This dynamic frequency selection not only enhances the reliability of the communication link but also minimizes the possibility of interference from other signals, which can be critical in emergency situations.

The MICOM-2ES, 2RS, and 2TS models feature advanced digital signal processing technologies that optimize audio clarity and reception. This ensures that communication remains clear even in noisy environments, which is a pivotal factor in emergency response scenarios. With a digital signal processor onboard, the system is capable of filtering out unwanted noise and enhancing the quality of the transmitted audio.

These models support multiple modes of operation, including both simplex and duplex communications. Such versatility allows users to adapt the system to various communication needs, augmenting its effectiveness in a range of operation scenarios. Furthermore, the MICOM-2 series is compatible with various antenna configurations, enhancing the operational range and flexibility of the system.

User-friendliness is another hallmark of the MICOM-2ES/2RS/2TS ALE systems, as they feature an intuitive user interface that simplifies operation, allowing for quick and efficient communication in high-pressure situations. Emergency responders and military personnel benefit greatly from such ease of use, leading to faster response times and improved overall coordination.

Additionally, the robustness of the Motorola MICOM-2 series ensures that it can withstand extreme environmental conditions. The units are designed to operate in harsh weather and rugged terrains, making them ideal for outdoor usage in emergency or military applications. All these features combined make the Motorola MICOM-2ES/2RS/2TS ALE a reliable choice for organizations that require high-performance communication solutions in demanding conditions.