New Buck Corporation 1110 manual Technical Service, Model, Modulating Valve

Page 38

TECHNICAL SERVICE

 

MODEL 1110

 

 

MODULATING VALVE

 

BTU.

10,000

10,000

Type Gas

Propane (LP)

Natural

Ignition

Piezo

 

Pressure Regulator Setting

9" W.C.

3.5" W.C.

Inlet Gas Pressure (in. of water)*

 

 

Maximum

14"

10.5" W.C.

Minimum

11"

5.0" W.C.

Dimensions, Inches (HxWxD)

 

 

Heater

22" x 20 - 1/8" x 7"

 

Weight (pounds)

 

 

Heater

45 pounds

 

Shipping

 

 

* For purposes of input adjustment

36

Image 38
Contents Manufacturer NEW BUCK CORPORATION P.O. Box NEW BUCK CORPORATIONMODEL 1110 VENT-FREEGAS HEATER 8000 Highway 226 South Spruce Pine, NCPage TABLE OF CONTENTS Page SAFETY INFORMATION WARNINGS Do not try to light any appliance 22.”WARNING Failure to keep the primary air openings of the burners clean may result in sooting and property damage.” PRODUCT IDENTIFICATION SAFETY DEVICE PRODUCT FEATURESUNPACKING PIEZO IGNITION SYSTEMMINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION 2.Freestanding heater with optional pedestal INSTALLATION1.Wall Mounted 3.Freestanding with optional wooden mantelCLEANING INFORMATION FREESTANDING WITH OPTIONAL PEDESTAL INSTALLATION FREESTANDING OPTIONAL WOODEN MANTEL INSTALLATIONOPTIONAL “L” BRACKETS 2 AND SCREWS 2 PRO PRODUCING ADEQUATE VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONVent-freeheater VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDINGVENTILATION AIR FROM OUTDOORS GAS CONNECTION FLAMEExternal Regulator Vent Pointing Down CONNECTING TO A GAS SUPPLYPropane Supply Tank Installation must include manual shutoff valve and plugged 1/2 NPT tap. Locate NPT tap within reach for test gauge hook-up.NPT tap must be upstream from unit GAS PRESSURE CHECK Front View of Logs LOG PLACEMENT FORLogs are shipped secured in unit OPERATING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS MODULATING VALVEMAXITROL for “LOW” LIGHTING INSTRUCTIONSto IGNITE and for “HIGH”O.D.S PILOT BURNER TO TURN OFF GAS TO APPLIANCEIGNITER ELECTRODE THERMO-COUPLE MANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATIONNATURAL FLAME CHECKFLAME PROPANEFigure 1815 - Correct Burner Flame Pattern BURNER FLAME PATTERNCORRECT FLAME PATTERN AT HIGH POSITION INCORRECT FLAME PATTERN AT HIGH POSITIONMOTOR WIRING DIAGRAMPOWER CORD JUMPERTHERMOSTATREPAIR PARTS SERVICINGIMPORTANT SAFEGUARDS CLEANINGTROUBLE-SHOOTING OBSERVED PROBLEMSOLUTION POSSIBLE1.Control knob is not fully pressed in Delayed ignition of burner 1. Heater produces a clinking MODULATING VALVE TECHNICAL SERVICEMODEL PARTS LIST BLOWN UP VIEW OF HEATER, FAN MOTOR, AND ALL REMOVABLE PARTSPARTS LIST Maxitrol ValveBLOWN UP VIEW OF BURNER ASSEMBLY LIMITED WARRANTY ON VENT-FREEGAS LOG HEATER NEW BUCK CORPORATION