New Buck Corporation 1110 manual Parts List

Page 39

PARTS LIST

KEY NO.

PART NUMBER

DESCRIPTION

QUANTITY

1

MF 112738

VENT ROD

3

2

PO 1127IM

BRASS TRIM

4

3

PO PNPSNH50JT

FRONT

1

4

MA 1127SC

FRONT SCREEN

1

5

P0 112706

INNER SHIELD CHROME

1

6

MF 112782

LOG HOLDER

2

7

A2-40-01

FAN MOTOR

1

8

PS 112724

MOTOR BRACE

1

9

PS 112740

SCREEN MOTOR COVER

1

10

PE KB9724

FAN SPEED CONTROL LABEL

1

11

PE BC204

RHEOSTAT

1

12

PE BC204A

RHEOSTAT KNOB

1

13

PE 400132

110 DEG. DISC THERMOSTAT

1

14

PE 30JUMPER

THERMO JUMPER WIRE

2

15

PE 400320

STRAIN RELIEF

1

16

PE 400240

POWER CORD

1

17

PO 22GAJ1712

BRASS COVER DOOR LOUVER

3

18

PO WALLMT

LOG SET

1

19

PH 101612PHPTEK

SCREW, #10 x 1/2" PAN

2

20

PH101634TEK

SCREW, #10 x 3/4" HEX

2

21

PH 103212HWSPS5

SCREW, #10 x 1/2" HEX

6

22

PH 6114DWPHILSC

DRYWALL SCREW, 6" x 1 1/2"

2

37

Image 39
Contents 8000 Highway 226 South Spruce Pine, NC NEW BUCK CORPORATIONMODEL 1110 VENT-FREEGAS HEATER Manufacturer NEW BUCK CORPORATION P.O. BoxPage TABLE OF CONTENTS Page SAFETY INFORMATION WARNINGS Do not try to light any appliance 22.”WARNING Failure to keep the primary air openings of the burners clean may result in sooting and property damage.” PRODUCT IDENTIFICATION PIEZO IGNITION SYSTEM PRODUCT FEATURESUNPACKING SAFETY DEVICEMINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION 3.Freestanding with optional wooden mantel INSTALLATION1.Wall Mounted 2.Freestanding heater with optional pedestalCLEANING INFORMATION FREESTANDING OPTIONAL WOODEN MANTEL INSTALLATION FREESTANDING WITH OPTIONAL PEDESTAL INSTALLATIONOPTIONAL “L” BRACKETS 2 AND SCREWS 2 PRO DETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PRODUCING ADEQUATE VENTILATIONVent-freeheater VENTILATION AIR FROM INSIDE BUILDING VENTILATION AIRVENTILATION AIR FROM OUTDOORS FLAME GAS CONNECTIONCONNECTING TO A GAS SUPPLY Propane Supply TankExternal Regulator Vent Pointing Down Installation must include manual shutoff valve and plugged 1/2 NPT tap. Locate NPT tap within reach for test gauge hook-up.NPT tap must be upstream from unit GAS PRESSURE CHECK LOG PLACEMENT FOR Logs are shipped secured in unitFront View of Logs FOR YOUR SAFETY, READ BEFORE LIGHTING LIGHTING INSTRUCTIONS MODULATING VALVEMAXITROLOPERATING INSTRUCTIONS for “HIGH” LIGHTING INSTRUCTIONSto IGNITE and for “LOW”TO TURN OFF GAS TO APPLIANCE IGNITER ELECTRODE THERMO-COUPLEO.D.S PILOT BURNER THERMOSTAT CONTROL OPERATION MANUAL LIGHTING PROCEDUREPROPANE FLAME CHECKFLAME NATURALINCORRECT FLAME PATTERN AT HIGH POSITION BURNER FLAME PATTERNCORRECT FLAME PATTERN AT HIGH POSITION Figure 1815 - Correct Burner Flame PatternJUMPERTHERMOSTAT WIRING DIAGRAMPOWER CORD MOTORSERVICING REPAIR PARTSCLEANING IMPORTANT SAFEGUARDSTROUBLE-SHOOTING POSSIBLE PROBLEMSOLUTION OBSERVED1.Control knob is not fully pressed in Delayed ignition of burner 1. Heater produces a clinking TECHNICAL SERVICE MODELMODULATING VALVE PARTS LIST MOTOR, AND ALL REMOVABLE PARTS BLOWN UP VIEW OF HEATER, FANMaxitrol Valve PARTS LISTBLOWN UP VIEW OF BURNER ASSEMBLY NEW BUCK CORPORATION LIMITED WARRANTY ON VENT-FREEGAS LOG HEATER