New Buck Corporation 1110 manual Observed, Possible, Problem, Cause, Solution

Page 34
OBSERVED

OBSERVED

POSSIBLE

 

 

 

PROBLEM

CAUSE

 

 

SOLUTION

 

 

 

 

 

1. Igniter button is pressed. No 1.

Igniter electrode positioned

1.

Replace igniter

spark at ODS/Pilot

incorrectly

 

 

 

2.

Igniter electrode broken

2.

Replace igniter

3.

Igniter electrode not

3.

Reconnect igniter cable

 

connected to igniter cable

 

 

 

4.

Igniter cable pinched or wet

4.

Free igniter cable if pinched

 

 

 

 

by any metal or tubing. Keep

 

 

 

 

igniter cable dry.

5.

Piezo igniter nut is loose

5.

Tighten nut holding piezo

 

 

 

 

igniter to heater cabinet. Nut

 

 

 

 

is located inside heater

 

 

 

 

cabinet at top.

6.

Broken igniter cable

6.

Replace igniter cable

7.

Bad piezo igniter

7.

Replace piezo igniter

 

 

 

 

 

2.Igniter button is Spark at ODS/Pilot No Ignition

pressed 1.

Gas supply turned off or

1.

Turn on gas supply or open

 

manual shutoff valve is

 

manual shutoff valve

 

closed

 

 

2.

Control knob not in “PILOT”

2.

Turn control knob to “PILOT”

 

position

 

position

3.

Control knob not pressed in

3.

Press in control knob while in

 

while in “PILOT” position

 

“PILOT” position.

4.

Air in gas lines when installed 4.

Continue to hold down control

 

 

 

knob. Repeat igniting

5.

Depleted gas supply

 

operation until air is removed.

 

 

5.

Contact local propane gas

6.

ODS/Pilot is clogged

 

company

 

 

6.

Clean ODS/Pilot or replace

7.

Gas regulator setting is not

 

ODS/Pilot assembly

 

correct

7.

Replace gas regulator

32

Image 34
Contents Manufacturer NEW BUCK CORPORATION P.O. Box NEW BUCK CORPORATIONMODEL 1110 VENT-FREEGAS HEATER 8000 Highway 226 South Spruce Pine, NCPage TABLE OF CONTENTS Page SAFETY INFORMATION WARNINGS Do not try to light any appliance 22.”WARNING Failure to keep the primary air openings of the burners clean may result in sooting and property damage.” PRODUCT IDENTIFICATION SAFETY DEVICE PRODUCT FEATURESUNPACKING PIEZO IGNITION SYSTEMMINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION 2.Freestanding heater with optional pedestal INSTALLATION1.Wall Mounted 3.Freestanding with optional wooden mantelCLEANING INFORMATION FREESTANDING WITH OPTIONAL PEDESTAL INSTALLATION FREESTANDING OPTIONAL WOODEN MANTEL INSTALLATIONOPTIONAL “L” BRACKETS 2 AND SCREWS 2 PRO PRODUCING ADEQUATE VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONVent-freeheater VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDINGVENTILATION AIR FROM OUTDOORS GAS CONNECTION FLAMEPropane Supply Tank CONNECTING TO A GAS SUPPLYExternal Regulator Vent Pointing Down Installation must include manual shutoff valve and plugged 1/2 NPT tap. Locate NPT tap within reach for test gauge hook-up.NPT tap must be upstream from unit GAS PRESSURE CHECK Logs are shipped secured in unit LOG PLACEMENT FORFront View of Logs LIGHTING INSTRUCTIONS MODULATING VALVEMAXITROL FOR YOUR SAFETY, READ BEFORE LIGHTINGOPERATING INSTRUCTIONS for “LOW” LIGHTING INSTRUCTIONSto IGNITE and for “HIGH”IGNITER ELECTRODE THERMO-COUPLE TO TURN OFF GAS TO APPLIANCEO.D.S PILOT BURNER MANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATIONNATURAL FLAME CHECKFLAME PROPANEFigure 1815 - Correct Burner Flame Pattern BURNER FLAME PATTERNCORRECT FLAME PATTERN AT HIGH POSITION INCORRECT FLAME PATTERN AT HIGH POSITIONMOTOR WIRING DIAGRAMPOWER CORD JUMPERTHERMOSTATREPAIR PARTS SERVICINGIMPORTANT SAFEGUARDS CLEANINGTROUBLE-SHOOTING OBSERVED PROBLEMSOLUTION POSSIBLE1.Control knob is not fully pressed in Delayed ignition of burner 1. Heater produces a clinking MODEL TECHNICAL SERVICEMODULATING VALVE PARTS LIST BLOWN UP VIEW OF HEATER, FAN MOTOR, AND ALL REMOVABLE PARTSPARTS LIST Maxitrol ValveBLOWN UP VIEW OF BURNER ASSEMBLY LIMITED WARRANTY ON VENT-FREEGAS LOG HEATER NEW BUCK CORPORATION