3 Maintenance and Service

Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.

When properly maintained, your fireplace will give you many years of trouble-free service. We recommend an- nual service by a qualified service technician.

A. Maintenance Tasks-Homeowner

Installation and repair should be done by a qualified service technician only. The fireplace should be inspected before use and at least annually by a professional service person.

The following tasks may be performed annually by the homeowner. If you are uncomfortable performing any of the listed tasks, please call your dealer for a service ap- pointment.

More frequent cleaning may be required due to lint from carpeting or other factors. Control compartment, burner and circulating air passageway of the fireplace must be kept clean.

CAUTION! Risk of Burns! The fireplace should be turned off and cooled before servicing.

Glass Cleaning

Frequency: Seasonally

By: Homeowner

Tools Needed: Protective gloves, glass cleaner, drop cloth and a stable work surface.

CAUTION! Handle fixed glass assembly with care. Glass is breakable.

Avoid striking, scratching or slamming glass

Avoid abrasive cleaners

DO NOT clean glass while it is hot

Prepare a work area large enough to accommodate fixed glass assembly and door frame by placing a drop cloth on a flat, stable surface.

Note: Fixed glass assembly and gasketing may have res- idue that can stain carpeting or floor surfaces.

Remove door or decorative front from fireplace and set aside on work surface.

See Sections 9.I and 9.K for instructions to remove fixed glass assembly.

Clean glass with a non-abrasive commercially available cleaner.

-Light deposits: Use a soft cloth with soap and water

-Heavy deposits: Use commercial fireplace glass cleaner (consult with your dealer)

Carefully set fixed glass assembly in place on fireplace. Hold glass in place with one hand and secure glass latches with the other hand.

Reinstall door or decorative front.

Doors, Surrounds, Fronts

Frequency: Annually

By: Homeowner

Tools needed: Protective gloves, stable work surface

Inspect for scratches, dents or other damage and repair as necessary.

Check that louvers are not blocked.

Vacuum and dust surfaces.

Remote Control

Frequency: Seasonally

By: Homeowner

Tools needed: Replacement batteries and remote con- trol instructions.

Locate remote control transmitter and receiver.

Verify operation of remote. Refer to remote control operation instructions for proper calibration and setup procedure.

Place batteries as needed in remote transmitters and battery-powered receivers.

Place remote control out of reach of children.

If not using your fireplace for an extended period of time (summer months, vacations/trips, etc), to prevent unin- tended operation:

Remove batteries from remote controls.

Unplug 6 volt adapter plug on IPI models.

Remove battery backup from control module.

Venting

Frequency: Seasonally

By: Homeowner

Tools needed: Protective gloves and safety glasses.

Inspect venting and termination cap for blockage or obstruction such plants, bird nests, leaves, snow, debris, etc.

Verify termination cap clearance to subsequent construc- tion (building additions, decks, fences, or sheds). See Sections 6 through 8.

Inspect through corrosion or separation.

Verify weather stripping, sealing and flashing remains intact.

Inspect draft shield to verify it is not damaged or missing.

14

Heat & Glo • VRT-AUB2123-980 Rev. H • 5/12

Image 14
Contents What to do if you smell gas Ref No GSCS20166 AS45532008SAI Global Heat & Glo VRT-AUB 2123-980 Rev. H 5/12 Listing Label Information/Location CongratulationsHomeowner Reference Information Table of Contents User GuideElectrical Information TroubleshootingGas Information Reference MaterialsLimited Lifetime Warranty Other RightsOther Rights Perth Listing and Code Approvals Operating Instructions User Guide Lighting Instructions IPI Final inspection byControl Module Operation Control ModuleFrequently Asked Questions After Fireplace is LitMaintenance and Service Logs Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection FireboxBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Selecting Appliance LocationOptional Stone Surround Installed Stone SurroundTermination Locations Vent Termination Minimum ClearancesMIN. Clearance in. mm Use of Elbows Flue InformationFlue Components Measuring StandardsFlueing Diagrams For Natural, Propane and Butane GasesNatural Gas One 90 Elbow System Natural Gas Two 90 Elbows System Minimum Maximum H1 + H2 Max 457 mm 610 mm Natural Gas Two 90 Elbows System Minimum Maximum Propane Three 90 Elbows System Minimum Maximum H1 + H2 Max + H1 + H2 = Max ft .97 m H1 Max. = 7 ft .13 m Flue Pipe Assembly Horizontal Penetration Framing StepFIG. B Minimum Clearance Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble Vertical Termination StepSecure Flashing with NON-HARDENING Sealant Roofing Nails Vertical Flue Restrictor Twist-lock the flue cap and sealWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe SLPVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Unbolting Appliance from the Pallet Appliance SetupRemove Shipping Materials Leveling and Bolting Down the ApplianceAccessories Top to Rear Flue ConversionInstalling the Baffle On Back of AppliancePositioning the Logs Placing Mineral WoolFront Door Glass Assembly Installation Inner Glass Door Assembly ReplacementAdjustments And Replacement Parts Components Removal For ServiceParts Replacement Install Trim and/or SurroundInstalling Vent Pipe SLP Pipe Assemble Vent SectionsAssemble Slip Sections Secure The Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Support Brackets Install FirestopsFor Horizontal Terminations using the SLP-TRAP Flue TerminationInstall Metal Roof Flashing Heat Shield Requirements for Horizontal TerminationAssemble and Install Storm Collar Install Vertical Termination CapGas Information Gas Pressure Requirements Gas ConnectionHeat & Glo VRT-AUB 2123-980 Rev. H 5/12 Optional Accessories Requirements Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Electrical InformationBlower Control Module Operation Fireplace Specific Information Kit ContentsInstallation Precautions IntroductionChanging Temperature Scale Installation of Remote Control HousingProgramming the RC300CE to the Control Module AUX300CE Module InstallationFan Installation Display Screen Idle When Remote is in on ModeStandby mode Function ButtonsAdjusting Flame Height About on ModeAbout OFF Mode Adjusting Fan SpeedSetting the Child Lock Adjusting ThermostatAdjusting Timer Power OutageFrequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire PlusIgnition System TroubleshootingSymptom Possible Cause Corrective Action IntelliFire Plus Ignition System Appliance Dimension Diagram Reference MaterialsAppliance Dimension with Stone Surround Diagram Hearth PadMaintenance Tasks Inspect Maintenance TasksCeiling Firestop Vent Components DiagramsElbow Support25 mm Vertical Termination Cap184 mm Service Parts Log Set Assembly Part number list on followingVRT-AUB VRT-AUB Contact Information

VRT-BZ-P-AUB, VRT-GY-N-AUB, VRT-BZ-N-AUB, VRT-GY-P-AUB specifications

Heat & Glo is renowned for its innovative fireplace solutions, and the LifeStyle series, including models VRT-BZ-N-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB, and VRT-GY-P-AUB, exemplifies the brand's commitment to quality and style. These contemporary fireplaces blend modern aesthetics with advanced technology, making them an ideal addition to any living space.

One of the standout features of these models is their versatile design that allows for seamless integration into any room. The LifeStyle series boasts multiple finish options, including a sleek bronze and an elegant gray, giving homeowners the flexibility to match their fireplace with their interior decor. The linear design not only promotes a minimalist look but also enhances the ambiance of any environment, serving as a captivating focal point.

In terms of technology, these fireplaces are equipped with advanced control systems, allowing users to adjust flame height, heat output, and ambiance with minimal effort. The intuitive controls can often be managed via a remote or smartphone app, providing convenience and flexibility for the modern homeowner.

Safety is also a key consideration in the LifeStyle series. With features such as automatic shut-off mechanisms and safety screens, these fireplaces prioritize user safety without compromising on style. The combustion technology employed ensures efficient heating and reduced emissions, making the LifeStyle series an environmentally conscious choice.

Additionally, with various installation options available, including built-in and wall-mounted configurations, these fireplaces can be customized to fit different spaces and preferences. This flexibility makes them perfect for both renovations and new constructions alike.

The LifeStyle series is designed for ease of maintenance, with accessible components that simplify cleaning and upkeep. This aspect is especially beneficial for busy homeowners who desire a stylish focal point in their homes without the burden of extensive maintenance demands.

In conclusion, Heat & Glo's LifeStyle VRT-BZ-N-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB, and VRT-GY-P-AUB models offer a unique combination of contemporary design, advanced technology, and user-friendly features. Whether for cozy evenings or entertaining guests, these fireplaces elevate any space while providing warmth and comfort.