Heat & Glo LifeStyle VRT-BZ-N-AUB Secure Flashing with NON-HARDENING Sealant Roofing Nails

Page 35

Step 3.

To install the round support box/wall thimble cover in a flat ceiling, cut a 229 mm square hole in the ceiling, centered on the hole drilled in Step 2. Frame the hole as shown in Figure 7.22.

CEILING JOISTS

SHINGLES OVERLAP ON TOP EDGE OF FLASHING

FRAMING

229 mm x 229 mm

ROUND CEILING SUPPORT BOX/WALL THIMBLE COVER

CAP AND STORM COLLAR NOT SHOWN FOR CLARITY

Figure 7.23

Step 7.

40 mm LONG WOOD SCREWS

Figure 7.22

Step 4.

Assemble the desired lengths of pipe and elbows neces- sary to reach from the gas stove up through the round sup- port box. Ensure that all pipe and elbow connections are in their fully twist-locked position. Assemble as instructed.

Step 5.

Cut a hole in the roof centered on the small drill hole placed in the roof in Step 2. The hole should be of sufficient size to meet the minimum requirements for clearance to com- bustibles, as specified. Continue to assemble lengths of pipe and elbows necessary to reach from the ceiling support box/wall thimble up through the roof line. Galva- nized pipe and elbows may be utilized in the attic, as well as above the roofline. The galvanized finish is desirable above the roofline, due to its higher corrosion resistance (compared to black pipe).

NOTE:

(1) If an offset is necessary in the attic to avoid obstruc- tions, it is important to support the flue pipe every 91.4cm to avoid excessive stress on the elbows, and possible separation. Wall straps are available for this purpose, Figure 7.10, page 15.

(2)Whenever possible, use 45° elbows, instead of 90° elbows. The 45° elbow offers less restriction to the flow of flue gases and intake air.

Step 6.

Slip the flashing over the pipe section(s) protruding through the roof. Secure the base of the flashing to the roof with roofing nails. Ensure the roofing material over- laps the top edge of the flashing as shown in Figure 7.23. Verify that the chimney is the required height above the roof. See roof pitch table, Figure 4.3.

Continue to assemble pipe sections until the height of the flue (before adding the termination cap) meets the mini- mum local code requirements. Note that for steep roof pitches, the flue height must be increased. See Roof Pitch Table (Figure 4.3). In high wind conditions, nearby trees adjoining rooflines, steep pitched roofs, and other similar factors can result in poor draft, or down drafting. In these cases increasing the flue height or switching to the high wind termination cap may solve this problem.

Step 8.

Slip the storm collar over the pipe, and push it down to the top of the flashing (Figure 7.24). Use non-hardening sealant above and below the joint between the storm collar and the pipe.

SECURE FLASHING WITH

NON-HARDENING SEALANT

AND ROOFING NAILS

Figure 7.24

Heat & Glo • VRT-AUB2123-980 Rev. H • 5/12

35

Image 35
Contents What to do if you smell gas Ref No GSCS20166 AS45532008SAI Global Heat & Glo VRT-AUB 2123-980 Rev. H 5/12 Listing Label Information/Location CongratulationsHomeowner Reference Information User Guide Table of ContentsReference Materials TroubleshootingGas Information Electrical InformationOther Rights Limited Lifetime WarrantyOther Rights Perth Listing and Code Approvals Operating Instructions User Guide Final inspection by Lighting Instructions IPIControl Module Control Module OperationAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Selecting Appliance Location Framing and ClearancesStone Surround Optional Stone Surround InstalledVent Termination Minimum Clearances Termination LocationsMIN. Clearance in. mm Measuring Standards Flue InformationFlue Components Use of ElbowsFor Natural, Propane and Butane Gases Flueing DiagramsNatural Gas One 90 Elbow System Natural Gas Two 90 Elbows System Minimum Maximum H1 + H2 Max 457 mm 610 mm Natural Gas Two 90 Elbows System Minimum Maximum Propane Three 90 Elbows System Minimum Maximum H1 + H2 Max + H1 + H2 = Max ft .97 m H1 Max. = 7 ft .13 m Step Flue Pipe Assembly Horizontal Penetration FramingFIG. B Minimum Clearance Assembling Slim Line Trim Ring and Heat Shield Installing Slim Line Trim Ring and Heat ShieldSlim Line Wall Thimble Step Vertical TerminationSecure Flashing with NON-HARDENING Sealant Roofing Nails Twist-lock the flue cap and seal Vertical Flue RestrictorCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe SLP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Leveling and Bolting Down the Appliance Appliance SetupRemove Shipping Materials Unbolting Appliance from the PalletTop to Rear Flue Conversion AccessoriesOn Back of Appliance Installing the BafflePlacing Mineral Wool Positioning the LogsInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationInstall Trim and/or Surround Components Removal For ServiceParts Replacement Adjustments And Replacement PartsAssemble Vent Sections Installing Vent Pipe SLP PipeSecure The Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsInstall Firestops Install Support BracketsFlue Termination For Horizontal Terminations using the SLP-TRAPHeat Shield Requirements for Horizontal Termination Install Metal Roof FlashingInstall Vertical Termination Cap Assemble and Install Storm CollarGas Pressure Requirements Gas Connection Gas InformationHeat & Glo VRT-AUB 2123-980 Rev. H 5/12 Electrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Accessories RequirementsBlower Control Module Operation Introduction Kit ContentsInstallation Precautions Fireplace Specific InformationInstallation of Remote Control Housing Changing Temperature ScaleProgramming the RC300CE to the Control Module AUX300CE Module InstallationFan Installation Function Buttons Idle When Remote is in on ModeStandby mode Display ScreenAdjusting Fan Speed About on ModeAbout OFF Mode Adjusting Flame HeightPower Outage Adjusting ThermostatAdjusting Timer Setting the Child LockSymptom Possible Cause Corrective Action Frequently Asked Questions/TroubleshootingIntelliFire PlusIgnition System TroubleshootingSymptom Possible Cause Corrective Action IntelliFire Plus Ignition System Reference Materials Appliance Dimension DiagramHearth Pad Appliance Dimension with Stone Surround DiagramInspect Maintenance Tasks Maintenance TasksSupport Vent Components DiagramsElbow Ceiling Firestop25 mm Vertical Termination Cap184 mm Log Set Assembly Part number list on following Service PartsVRT-AUB VRT-AUB Contact Information

VRT-BZ-P-AUB, VRT-GY-N-AUB, VRT-BZ-N-AUB, VRT-GY-P-AUB specifications

Heat & Glo is renowned for its innovative fireplace solutions, and the LifeStyle series, including models VRT-BZ-N-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB, and VRT-GY-P-AUB, exemplifies the brand's commitment to quality and style. These contemporary fireplaces blend modern aesthetics with advanced technology, making them an ideal addition to any living space.

One of the standout features of these models is their versatile design that allows for seamless integration into any room. The LifeStyle series boasts multiple finish options, including a sleek bronze and an elegant gray, giving homeowners the flexibility to match their fireplace with their interior decor. The linear design not only promotes a minimalist look but also enhances the ambiance of any environment, serving as a captivating focal point.

In terms of technology, these fireplaces are equipped with advanced control systems, allowing users to adjust flame height, heat output, and ambiance with minimal effort. The intuitive controls can often be managed via a remote or smartphone app, providing convenience and flexibility for the modern homeowner.

Safety is also a key consideration in the LifeStyle series. With features such as automatic shut-off mechanisms and safety screens, these fireplaces prioritize user safety without compromising on style. The combustion technology employed ensures efficient heating and reduced emissions, making the LifeStyle series an environmentally conscious choice.

Additionally, with various installation options available, including built-in and wall-mounted configurations, these fireplaces can be customized to fit different spaces and preferences. This flexibility makes them perfect for both renovations and new constructions alike.

The LifeStyle series is designed for ease of maintenance, with accessible components that simplify cleaning and upkeep. This aspect is especially beneficial for busy homeowners who desire a stylish focal point in their homes without the burden of extensive maintenance demands.

In conclusion, Heat & Glo's LifeStyle VRT-BZ-N-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB, and VRT-GY-P-AUB models offer a unique combination of contemporary design, advanced technology, and user-friendly features. Whether for cozy evenings or entertaining guests, these fireplaces elevate any space while providing warmth and comfort.