Heat & Glo LifeStyle VRT-GY-P-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB Inspect Maintenance Tasks

Page 69

C. Maintenance Tasks

Inspect

 

Maintenance Tasks

 

 

Doors

1. Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

2.

Verify no obstructions to airflow.

 

 

 

 

3.

Verify maintenance of proper clearance to combustible household objects.

 

 

Gasket Seal, Glass

1. Inspect gasket seal and its condition.

Assembly and Glass

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

 

 

 

 

 

3.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

4. Verify that latches engage properly, clip studs are not stripped, and glass attachment components are intact

 

 

and operating properly. Replace as necessary.

 

 

 

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.

 

 

Valve Compartment

1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw tips

and Firebox Top

 

that have penetrated the sheet metal are sharp and should be avoided.

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

Logs

1. Inspect for broken, damaged, or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

Firebox

1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.

 

 

 

 

2.

Replace appliance if firebox has been perforated.

 

 

Burner Ignition and

1. Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

 

 

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.

 

 

 

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

7.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

8.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

9. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery

 

 

cloth or replace as required.

Flueing

1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks, fences or sheds)

 

 

has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

 

Remote controls

1. Verify operation of remote.

 

 

 

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

 

Heat & Glo • VRT-AUB2123-980 Rev. H • 5/12

69

Image 69
Contents Ref No GSCS20166 AS45532008 SAI GlobalWhat to do if you smell gas Heat & Glo VRT-AUB 2123-980 Rev. H 5/12 Congratulations Homeowner Reference InformationListing Label Information/Location User Guide Table of ContentsGas Information TroubleshootingElectrical Information Reference MaterialsOther Rights Limited Lifetime WarrantyOther Rights Perth Listing and Code Approvals Operating Instructions User Guide Final inspection by Lighting Instructions IPIControl Module Control Module OperationAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianLogs FireboxIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesStone Surround Optional Stone Surround InstalledVent Termination Minimum Clearances Termination LocationsMIN. Clearance in. mm Flue Components Flue InformationUse of Elbows Measuring StandardsFor Natural, Propane and Butane Gases Flueing DiagramsNatural Gas One 90 Elbow System Natural Gas Two 90 Elbows System Minimum Maximum H1 + H2 Max 457 mm 610 mm Natural Gas Two 90 Elbows System Minimum Maximum Propane Three 90 Elbows System Minimum Maximum H1 + H2 Max + H1 + H2 = Max ft .97 m H1 Max. = 7 ft .13 m Step Flue Pipe Assembly Horizontal Penetration FramingFIG. B Minimum Clearance Installing Slim Line Trim Ring and Heat Shield Slim Line Wall ThimbleAssembling Slim Line Trim Ring and Heat Shield Step Vertical TerminationSecure Flashing with NON-HARDENING Sealant Roofing Nails Twist-lock the flue cap and seal Vertical Flue RestrictorPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe SLP Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Remove Shipping Materials Appliance SetupUnbolting Appliance from the Pallet Leveling and Bolting Down the ApplianceTop to Rear Flue Conversion AccessoriesOn Back of Appliance Installing the BafflePlacing Mineral Wool Positioning the LogsInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationParts Replacement Components Removal For ServiceAdjustments And Replacement Parts Install Trim and/or SurroundAssemble Vent Sections Installing Vent Pipe SLP PipeSecure The Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsInstall Firestops Install Support BracketsFlue Termination For Horizontal Terminations using the SLP-TRAPHeat Shield Requirements for Horizontal Termination Install Metal Roof FlashingInstall Vertical Termination Cap Assemble and Install Storm CollarGas Pressure Requirements Gas Connection Gas InformationHeat & Glo VRT-AUB 2123-980 Rev. H 5/12 IntelliFire PlusTM Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical InformationBlower Control Module Operation Installation Precautions Kit ContentsFireplace Specific Information IntroductionInstallation of Remote Control Housing Changing Temperature ScaleAUX300CE Module Installation Fan InstallationProgramming the RC300CE to the Control Module Standby mode Idle When Remote is in on ModeDisplay Screen Function ButtonsAbout OFF Mode About on ModeAdjusting Flame Height Adjusting Fan SpeedAdjusting Timer Adjusting ThermostatSetting the Child Lock Power OutageSymptom Possible Cause Corrective Action Frequently Asked Questions/TroubleshootingTroubleshooting Symptom Possible Cause Corrective ActionIntelliFire PlusIgnition System IntelliFire Plus Ignition System Reference Materials Appliance Dimension DiagramHearth Pad Appliance Dimension with Stone Surround DiagramInspect Maintenance Tasks Maintenance TasksElbow Vent Components DiagramsCeiling Firestop SupportVertical Termination Cap 184 mm25 mm Log Set Assembly Part number list on following Service PartsVRT-AUB VRT-AUB Contact Information

VRT-BZ-P-AUB, VRT-GY-N-AUB, VRT-BZ-N-AUB, VRT-GY-P-AUB specifications

Heat & Glo is renowned for its innovative fireplace solutions, and the LifeStyle series, including models VRT-BZ-N-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB, and VRT-GY-P-AUB, exemplifies the brand's commitment to quality and style. These contemporary fireplaces blend modern aesthetics with advanced technology, making them an ideal addition to any living space.

One of the standout features of these models is their versatile design that allows for seamless integration into any room. The LifeStyle series boasts multiple finish options, including a sleek bronze and an elegant gray, giving homeowners the flexibility to match their fireplace with their interior decor. The linear design not only promotes a minimalist look but also enhances the ambiance of any environment, serving as a captivating focal point.

In terms of technology, these fireplaces are equipped with advanced control systems, allowing users to adjust flame height, heat output, and ambiance with minimal effort. The intuitive controls can often be managed via a remote or smartphone app, providing convenience and flexibility for the modern homeowner.

Safety is also a key consideration in the LifeStyle series. With features such as automatic shut-off mechanisms and safety screens, these fireplaces prioritize user safety without compromising on style. The combustion technology employed ensures efficient heating and reduced emissions, making the LifeStyle series an environmentally conscious choice.

Additionally, with various installation options available, including built-in and wall-mounted configurations, these fireplaces can be customized to fit different spaces and preferences. This flexibility makes them perfect for both renovations and new constructions alike.

The LifeStyle series is designed for ease of maintenance, with accessible components that simplify cleaning and upkeep. This aspect is especially beneficial for busy homeowners who desire a stylish focal point in their homes without the burden of extensive maintenance demands.

In conclusion, Heat & Glo's LifeStyle VRT-BZ-N-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB, and VRT-GY-P-AUB models offer a unique combination of contemporary design, advanced technology, and user-friendly features. Whether for cozy evenings or entertaining guests, these fireplaces elevate any space while providing warmth and comfort.