Heat & Glo LifeStyle VRT-BZ-N-AUB Adjusting Thermostat, Adjusting Timer, Setting the Child Lock

Page 63

Adjusting Thermostat

Press the MENU button to activate the menu.

Using the UP and DOWN arrows highlight the THERMO icon and press SELECT.

Use the UP and DOWN arrows to turn the THERMO ON or OFF, then press SELECT (the SET TEMP will start blinking). Using the UP and DOWN arrows select the desired temperature and press SELECT.

NOTICE: If the THERMO function is on, the SET TEMP can be adjusted at any time by pressing the UP and DOWN arrows.

NOTICE: As the ROOM TEMP (RT) approaches SET TEMP (ST), the remote system will automatically adjust the flame height. If the RT rises above ST, the fireplace will shut down the main burner. After this, the fireplace will turn back on after the RT drops below the ST.

NOTICE: The system will remember the previous TEM- PERATURE setting when THERMOSTAT mode is cycled ON or OFF.

NOTICE: If your installation includes an optional wired ON/ OFF wall switch, it should be in the OFF position when using the RC300AU in thermostat mode.

Adjusting Timer

Press the MENU button to activate the menu.

Using the UP and DOWN arrows highlight the TIMER icon and press SELECT.

Use the UP and DOWN arrows to turn the TIMER ON or OFF, then press SELECT. Using the UP and DOWN arrows select the desired set time and press SELECT. Timer operates in increments of 15, 30, 45, 60, 90, 120 and 180 minutes.

Setting the Child Lock

Press and hold the MENU and UP arrow buttons simul- taneously for 4 seconds to enable or disable the child lock feature.

NOTICE: No functions will be usable until child lock feature is disabled.

Power Outage

If fireplace battery backup system IS installed at time of power outage, fireplace operation will not be interrupted.

If fireplace battery backup system IS NOT installed at time of power outage, fireplace will shut off. To resume fireplace operation, install battery backup.

NOTICE: Battery polarity must be correct or module damage will occur.

Manual Fireplace Shutoff

In the unlikely event that the remote wall switch malfunc- tions and will not turn off the fireplace, call your dealer for service assistance. In the meantime, you may choose one of the following actions to turn off the fireplace:

CAUTION! Risk of burns! Fireplace surfaces are hot when operating and during cool down. Use care and wear gloves when opening the front and accessing com- ponents inside the fireplace.

Check remote screen for battery level indicator, replace the batteries if low battery is indicated (See Figure 12.13).

Turn off the control module:

Open or remove the decorative front to access the control module.

Move switch to OFF (See Figure 12.11).

Disconnect power to the control module:

Open or remove the decorative front to access power cord to the junction box and/or back-up batteries.

Unplug the control module and/or remove back-up batteries.

Shut off gas to the appliance:

Open or remove the decorative front and locate the gas shut-off valve to the left of the gas control.

Rotate the shut off valve 90 degrees to turn off gas supply.

Turn off power to the fireplace (if back-up batteries are not installed):

Locate house circuit breaker for fireplace.

Turn off the circuit breaker.

Heat & Glo • VRT-AUB2123-980 Rev. H • 5/12

63

Image 63
Contents Ref No GSCS20166 AS45532008 SAI GlobalWhat to do if you smell gas Heat & Glo VRT-AUB 2123-980 Rev. H 5/12 Congratulations Homeowner Reference InformationListing Label Information/Location User Guide Table of ContentsReference Materials TroubleshootingGas Information Electrical InformationOther Rights Limited Lifetime WarrantyOther Rights Perth Listing and Code Approvals Operating Instructions User Guide Final inspection by Lighting Instructions IPIControl Module Control Module OperationAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Selecting Appliance Location Framing and ClearancesStone Surround Optional Stone Surround InstalledVent Termination Minimum Clearances Termination LocationsMIN. Clearance in. mm Measuring Standards Flue InformationFlue Components Use of ElbowsFor Natural, Propane and Butane Gases Flueing DiagramsNatural Gas One 90 Elbow System Natural Gas Two 90 Elbows System Minimum Maximum H1 + H2 Max 457 mm 610 mm Natural Gas Two 90 Elbows System Minimum Maximum Propane Three 90 Elbows System Minimum Maximum H1 + H2 Max + H1 + H2 = Max ft .97 m H1 Max. = 7 ft .13 m Step Flue Pipe Assembly Horizontal Penetration FramingFIG. B Minimum Clearance Installing Slim Line Trim Ring and Heat Shield Slim Line Wall ThimbleAssembling Slim Line Trim Ring and Heat Shield Step Vertical TerminationSecure Flashing with NON-HARDENING Sealant Roofing Nails Twist-lock the flue cap and seal Vertical Flue RestrictorCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe SLP Install the Ceiling FirestopInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Leveling and Bolting Down the Appliance Appliance SetupRemove Shipping Materials Unbolting Appliance from the PalletTop to Rear Flue Conversion AccessoriesOn Back of Appliance Installing the BafflePlacing Mineral Wool Positioning the LogsInner Glass Door Assembly Replacement Front Door Glass Assembly InstallationInstall Trim and/or Surround Components Removal For ServiceParts Replacement Adjustments And Replacement PartsAssemble Vent Sections Installing Vent Pipe SLP PipeSecure The Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsInstall Firestops Install Support BracketsFlue Termination For Horizontal Terminations using the SLP-TRAPHeat Shield Requirements for Horizontal Termination Install Metal Roof FlashingInstall Vertical Termination Cap Assemble and Install Storm CollarGas Pressure Requirements Gas Connection Gas InformationHeat & Glo VRT-AUB 2123-980 Rev. H 5/12 Electrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Accessories RequirementsBlower Control Module Operation Introduction Kit ContentsInstallation Precautions Fireplace Specific InformationInstallation of Remote Control Housing Changing Temperature ScaleAUX300CE Module Installation Fan InstallationProgramming the RC300CE to the Control Module Function Buttons Idle When Remote is in on ModeStandby mode Display ScreenAdjusting Fan Speed About on ModeAbout OFF Mode Adjusting Flame HeightPower Outage Adjusting ThermostatAdjusting Timer Setting the Child LockSymptom Possible Cause Corrective Action Frequently Asked Questions/TroubleshootingTroubleshooting Symptom Possible Cause Corrective ActionIntelliFire PlusIgnition System IntelliFire Plus Ignition System Reference Materials Appliance Dimension DiagramHearth Pad Appliance Dimension with Stone Surround DiagramInspect Maintenance Tasks Maintenance TasksSupport Vent Components DiagramsElbow Ceiling FirestopVertical Termination Cap 184 mm25 mm Log Set Assembly Part number list on following Service PartsVRT-AUB VRT-AUB Contact Information

VRT-BZ-P-AUB, VRT-GY-N-AUB, VRT-BZ-N-AUB, VRT-GY-P-AUB specifications

Heat & Glo is renowned for its innovative fireplace solutions, and the LifeStyle series, including models VRT-BZ-N-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB, and VRT-GY-P-AUB, exemplifies the brand's commitment to quality and style. These contemporary fireplaces blend modern aesthetics with advanced technology, making them an ideal addition to any living space.

One of the standout features of these models is their versatile design that allows for seamless integration into any room. The LifeStyle series boasts multiple finish options, including a sleek bronze and an elegant gray, giving homeowners the flexibility to match their fireplace with their interior decor. The linear design not only promotes a minimalist look but also enhances the ambiance of any environment, serving as a captivating focal point.

In terms of technology, these fireplaces are equipped with advanced control systems, allowing users to adjust flame height, heat output, and ambiance with minimal effort. The intuitive controls can often be managed via a remote or smartphone app, providing convenience and flexibility for the modern homeowner.

Safety is also a key consideration in the LifeStyle series. With features such as automatic shut-off mechanisms and safety screens, these fireplaces prioritize user safety without compromising on style. The combustion technology employed ensures efficient heating and reduced emissions, making the LifeStyle series an environmentally conscious choice.

Additionally, with various installation options available, including built-in and wall-mounted configurations, these fireplaces can be customized to fit different spaces and preferences. This flexibility makes them perfect for both renovations and new constructions alike.

The LifeStyle series is designed for ease of maintenance, with accessible components that simplify cleaning and upkeep. This aspect is especially beneficial for busy homeowners who desire a stylish focal point in their homes without the burden of extensive maintenance demands.

In conclusion, Heat & Glo's LifeStyle VRT-BZ-N-AUB, VRT-GY-N-AUB, VRT-BZ-P-AUB, and VRT-GY-P-AUB models offer a unique combination of contemporary design, advanced technology, and user-friendly features. Whether for cozy evenings or entertaining guests, these fireplaces elevate any space while providing warmth and comfort.