B. Constructing the Appliance Chase

A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should enclosed inside the chase.

NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase may vary with the type of building. These instructions are not substitutes for the requirements of local building codes. Therefore, you MUST check local building codes to determine the requirements to these steps.

Chases should be constructed in the manner of all out- side walls of the home to prevent cold air drafting prob- lems. The chase should not break the outside building envelope in any manner.

Walls, ceiling, base plate and cantilever fl oor of the chase should be insulated. Vapor and air infiltration barriers should be installed in the chase as per regional codes for the rest of the home. Additionally, in regions where cold air infi ltration may be an issue, the inside surfaces may be sheetrocked and taped for maximum air tightness.

To further prevent drafts, the wall shield and ceiling fire- stops should be caulked with caulk with a minimum of 300ºF continuous exposure rating to seal gaps. Gas line holes and other openings should be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with unfaced insulation. If the appliance is being installed on a cement surface, a layer of plywood may be placed underneath to prevent conducting cold up into the room.

The factory-supplied non-combustible board must be used in all installations. It must be directly attached to structural framing adjacent to the appliance. Screw fas- teners should be installed in the pilot holes provided in the outer perimeter of the non-combustible board. See Figure 13.3.

The factory-supplied board is designed such that its edg- es will be at the approximate center of the adjacent fram- ing, assuming it is 1-1/2 in. nominal thickness. This will allow the wallboard joints to occur on the center of the framing where the panels can be fastened properly. If the framing thickness is less than 1-1/2 in. nominal, such as with formed steel systems, then it may be necessary to adjust the adjacent framing dimensions so that the non- combustible board and wallboard joints are centered on the framing.

18

Heat & Glo • SLR-B2195-900 Rev. P • 12/11

Image 18
Contents Model What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Decorative Doors and FrontsWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsInitial Break-in Procedure After Fireplace is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection FireboxGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase Minimum Framing Dimensions ClearancesMantel and Wall Projections Combustible Mantels IN. Thick Wall Sheathing12Non-combustible Mantels Thick Wall Sheathing Non-Combustible Zone Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Top Vent Horizontal Termination Venting with 1 elbow Top Vent Horizontal Termination Venting with 2 elbows Top Vent Horizontal Termination Venting with 3 elbows SLR-BInstalled Horizontally Top Vent Vertical Termination No Elbows V1 = 44 ft. Max .4 m Exhaust restrictor InstructionsTop Vent Vertical Termination Venting with 2 elbows V1 Minimum Maximum V1 + V2 MinimumTop Vent Vertical Termination Venting with 3 elbows Top Vent Vertical Termination Venting with 4 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MINClearances to Combustibles Prior to installing the gas applianceCoaxial to Colinear Venting Termination Cap Flue DamperFloor Hearth Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Termination CAP Inlet AIR Vent PipeWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentSecuring and Leveling the Appliance Proper Positioning, Leveling And Securing Of AnInstalling Vent Pipe SLP Pipe Assemble Vent SectionsAssemble Slip Sections Secure The Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Install Decorative Wall ComponentsHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 17 Venting through the wallFuel Conversion Access Through the Valve AssemblyGas Information Gas PressureGas Connection Disconnect Gas ValveIntelliFire Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical InformationElectrical Service and Repair Junction Box Installation Finishing Instructions FinishingFraming and Finishing Instructions Non-Combustible Materials SpecificationNON-COMBUSTIBLE Boar D Painting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard Wallboard Joint-Crack Prevention and RepairCombustible Mantels MAX Measurement 14 IN. from TOP of MIN. Fireplace OpeningFacing Material Overlap Fit Method Tonic or Martini Decorative FrontHeat & Glo SLR-B 2195-900 Rev. P 12/11 Dimensions of Tonic Decorative Front Decorative FrontsAppliance Setup Pilot Shield Install the Mesh Air Shutter SettingAir Shutter Settings Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System With fi xed glass assembly in place, verify that fl ame is en Appliance Dimension Diagram Reference MaterialsCOOL-ADD Vent Components DiagramsDRC-RADIUS DVP-BEK2Extended Heat Shield SLP-45 45 ElbowSLP90- 90 Elbow Ceiling FirestopSnorkel Support Box-Black AdapterBlack 305 mm 178 mm 15-1/2 394 mm SLP-TRAP SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAPSLP-LPC Optional Wire HarnessPVI-SLP LINK-DV30B DVP-2SL DV-46DVA-GCLContact Information Do not Discard this Manual

SLR-B (COSMO) specifications

The Heat & Glo LifeStyle SLR-B (COSMO) is a revolutionary gas fireplace that embodies modern design while prioritizing efficiency and sophistication. Known for its sleek lines and contemporary aesthetic, the SLR-B blends seamlessly into various home décors, making it a popular choice among homeowners who value both style and functionality.

One of the standout features of the SLR-B is its panoramic viewing glass. The expansive front glass panel offers an unobstructed view of the flames, creating a stunning focal point in any room. This design not only enhances the ambiance but also allows for a more radiant heat output, efficiently warming the space while inviting a captivating visual element into the home.

The SLR-B utilizes advanced burner technology, which ensures a clean and efficient burn, producing realistic flames that mimic the look of natural wood fires. The unique firebox design enhances combustion efficiency, maximizing heat output while minimizing emissions. This aligns with modern environmental standards and provides homeowners with peace of mind regarding their energy consumption.

Compatibility with home automation systems is another attractive aspect of the SLR-B. With options for remote control and smart technology integration, users can control the fireplace settings from anywhere in the home, providing convenience and comfort. The inclusion of adjustable flame height adds personalization, allowing users to create the ideal atmosphere based on their preferences.

Safety is paramount in the design of the SLR-B. The fireplace comes with a sealed combustion system, which prevents drafts and enhances indoor air quality by minimizing the infiltration of outside air. Additionally, an intuitive control system informs users of the fireplace's status and ensures the right operation settings, contributing to a safer user experience.

With customizable media options, including various decorative stones or logs, the SLR-B allows for personal expression, harmonizing the design with individual tastes. This versatility makes it suitable for diverse spaces, from modern apartments to traditional homes.

In summary, the Heat & Glo LifeStyle SLR-B (COSMO) combines cutting-edge technology with aesthetic appeal. Its panoramic design, eco-friendly combustion, smart technology integration, safety features, and customizable options make it a top choice for homeowners seeking a sophisticated heating solution that enhances their living spaces.