D. Install Attic Insulation Shield

WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield.

The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constructed of 26 gauge minimum metal that extends at least 2 in. (51 mm) above insulation.

Attic shields must meet specifi ed clearance and be se- cured in place.

Flat Ceiling Installation

• Remove one shield from box.

NOTICE: Cut previously installed batt insulation to make room for the attic insulation shield.

Wrap shield around pipe if pipe is already installed in area to be insulated.

Match the three holes in each side and fasten with three screws to form a tube.

Bend three tabs on the bottom of the shield outward to allow attachment to the ceiling fi restop.

Bend the remaining bottom tabs inward 90° to maintain the air space between the pipe and the shield. Set the shield on the ceiling fi restop and attach to the fi restop.

Bend all tabs inward 90° around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance.

Vaulted Ceiling Installation

• Remove one shield from box.

NOTICE: Cut previously installed batt insulation to make room for the attic insulation shield.

Cut the attic insulation shield (if application is for vaulted ceiling) to fi t your ceiling pitch. Snip cut edge to recreate 1 in. bend tabs all the way around the bottom.

Wrap shield around pipe if pipe is already installed in area to be insulated.

Match the three holes in each side and fasten with three screws to form a tube.

Bend three tabs on the bottom of the shield outward to allow attachment to the ceiling fi restop.

Bend the remaining bottom tabs inward 90° to maintain the air space between the pipe and the shield. Set the shield on the ceiling fi restop and attach to the fi restop.

Bend all tabs inward 90° around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance.

BEND ALL TABS INWARD 90°

TO MAINTAIN CLEARANCE

AND PREVENT INSULATION

FROM FALLING INSIDE

 

BEND 3 TABS

 

OUTWARD TO

 

FASTEN TO CEILING

 

FIRESTOP-BEND

 

REMAINING TABS

 

INWARD 90 DEGREES

 

TO MAINTAIN

INSERT 3

CLEARANCE

 

SCREWS

 

Figure 8.6 Attic Insulation Shield

Heat & Glo • SLR-B2195-900 Rev. P • 12/11

37

Image 37
Contents What to do if you smell gas ModelHOT Surfaces Homeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyClear Space Decorative Doors and FrontsFinal inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveInitial Break-in Procedure Frequently Asked QuestionsIssue Solutions After Fireplace is LitMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianVenting FireboxTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase Clearances Minimum Framing DimensionsCombustible Mantels IN. Thick Wall Sheathing12 Mantel and Wall ProjectionsNon-combustible Mantels Thick Wall Sheathing Non-Combustible Zone Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Covered Alcove ApplicationsVent Information and Diagrams Top Vent Horizontal Termination Venting with 1 elbow Top Vent Horizontal Termination Venting with 2 elbows SLR-B Top Vent Horizontal Termination Venting with 3 elbowsInstalled Horizontally Exhaust restrictor Instructions Top Vent Vertical Termination No Elbows V1 = 44 ft. Max .4 mV1 Minimum Maximum V1 + V2 Minimum Top Vent Vertical Termination Venting with 2 elbowsTop Vent Vertical Termination Venting with 3 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MIN Top Vent Vertical Termination Venting with 4 elbowsCoaxial to Colinear Venting Prior to installing the gas applianceClearances to Combustibles Termination Cap Flue DamperConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Connecting the DV-46DVA-GCL Adapter to Appliance Top VentFloor Hearth Termination CAP Inlet AIR Vent PipePipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe SLP Install the Ceiling FirestopFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Top Vent Appliance PreparationProper Positioning, Leveling And Securing Of An Securing and Leveling the ApplianceAssemble Vent Sections Installing Vent Pipe SLP PipeSecure The Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingInstall Decorative Wall Components Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination 17 Venting through the wall Install Horizontal Termination CapGas Information Access Through the Valve AssemblyFuel Conversion Gas PressureDisconnect Gas Valve Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntelliFire Ignition System Wiring Electrical InformationElectrical Service and Repair Junction Box Installation Framing and Finishing Instructions FinishingFinishing Instructions Non-Combustible Materials SpecificationNON-COMBUSTIBLE Boar D Finishing Around Opening with Gypsum Wallboard Finish and Sealing JointsPainting Wallboard Joint-Crack Prevention and RepairMAX Measurement 14 IN. from TOP of MIN. Fireplace Opening Combustible MantelsOverlap Fit Method Tonic or Martini Decorative Front Facing MaterialHeat & Glo SLR-B 2195-900 Rev. P 12/11 Decorative Fronts Dimensions of Tonic Decorative FrontAppliance Setup Pilot Shield Air Shutter Setting Install the MeshAir Shutter Settings Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Ignition System With fi xed glass assembly in place, verify that fl ame is en Reference Materials Appliance Dimension DiagramDRC-RADIUS Vent Components DiagramsCOOL-ADD DVP-BEK2SLP90- 90 Elbow SLP-45 45 ElbowExtended Heat Shield Ceiling FirestopAdapter Snorkel Support Box-BlackBlack 305 mm 178 mm 15-1/2 394 mm SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP SLP-TRAPPVI-SLP Optional Wire HarnessSLP-LPC LINK-DV30B DVP-2SL DV-46DVA-GCLDo not Discard this Manual Contact Information

SLR-B (COSMO) specifications

The Heat & Glo LifeStyle SLR-B (COSMO) is a revolutionary gas fireplace that embodies modern design while prioritizing efficiency and sophistication. Known for its sleek lines and contemporary aesthetic, the SLR-B blends seamlessly into various home décors, making it a popular choice among homeowners who value both style and functionality.

One of the standout features of the SLR-B is its panoramic viewing glass. The expansive front glass panel offers an unobstructed view of the flames, creating a stunning focal point in any room. This design not only enhances the ambiance but also allows for a more radiant heat output, efficiently warming the space while inviting a captivating visual element into the home.

The SLR-B utilizes advanced burner technology, which ensures a clean and efficient burn, producing realistic flames that mimic the look of natural wood fires. The unique firebox design enhances combustion efficiency, maximizing heat output while minimizing emissions. This aligns with modern environmental standards and provides homeowners with peace of mind regarding their energy consumption.

Compatibility with home automation systems is another attractive aspect of the SLR-B. With options for remote control and smart technology integration, users can control the fireplace settings from anywhere in the home, providing convenience and comfort. The inclusion of adjustable flame height adds personalization, allowing users to create the ideal atmosphere based on their preferences.

Safety is paramount in the design of the SLR-B. The fireplace comes with a sealed combustion system, which prevents drafts and enhances indoor air quality by minimizing the infiltration of outside air. Additionally, an intuitive control system informs users of the fireplace's status and ensures the right operation settings, contributing to a safer user experience.

With customizable media options, including various decorative stones or logs, the SLR-B allows for personal expression, harmonizing the design with individual tastes. This versatility makes it suitable for diverse spaces, from modern apartments to traditional homes.

In summary, the Heat & Glo LifeStyle SLR-B (COSMO) combines cutting-edge technology with aesthetic appeal. Its panoramic design, eco-friendly combustion, smart technology integration, safety features, and customizable options make it a top choice for homeowners seeking a sophisticated heating solution that enhances their living spaces.