Heat & Glo LifeStyle SLR-B (COSMO) owner manual Gas Connection, Disconnect Gas Valve

Page 47

Figure 11.4. Disconnect Gas Valve

Note: Install the gas supply line in accordance with local codes, if any. If not, follow ANSI 223.1. Installation should be done by a qualifi ed installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter).

Note: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 in. (13 mm) T-handle manual shut-off valve and fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Valve Pressure Taps

The pressure taps are available through the front of the appliance. The decorative mesh front and fi replace gas assembly must be removed to gain access to the pressure taps. See Figure 11.5.

PRESSURE TAPS

OPTIONAL REMOTE

 

RECEIVER

Figure 11.5 Valve Pressure Taps and Remote Receiver Location

Note: The manifold and inlet pressure tabs can be ac- cessed from the front of the fi replace when valve assembly is installed.

C. Gas Connection

Refer to Reference Section 16 for location of gas line access in appliance.

Gas line may be run through knockout(s) provided.

The gap between supply piping and gas access hole may be caulked with caulk with a minimum of 300ºF continuous exposure rating or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

Ensure that gas line does not come in contact with outer wrap of the appliance. Follow local codes.

Pipe incoming gas line into valve compartment.

Connect incoming gas line to the 1/2 in. (13 mm) connection on manual shutoff valve.

WARNING! Risk of Fire or Explosion! Support control when attaching pipe to prevent bending gas line.

• A small amount of air will be in the gas supply lines.

WARNING! Risk of Fire or Explosion! Gas build-up dur- ing line purge could ignite.

Purge should be performed by qualified service technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

Light the appliance. It will take a short time for air to purge from lines. When purging is complete the appliance will light and operate normally.

WARNING! Risk of Fire, Explosion or Asphyxiation! Check all fittings and connections with a non-corrosive commercially available leak-check solution. DO NOT use open flame. Fittings and connections could have loos- ened during shipping and handling.

WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce burner orifice 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce burner orifi ce 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Heat & Glo • SLR-B2195-900 Rev. P • 12/11

47

Image 47
Contents HOT Surfaces ModelWhat to do if you smell gas Homeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Decorative Doors and Fronts Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceGAS Valve Lighting Instructions IPIFinal inspection by What to do if YOU Smell GASAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Issue SolutionsRemote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningFirebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Selecting Appliance Location Framing and ClearancesConstructing the Appliance Chase Clearances Minimum Framing DimensionsNon-combustible Mantels Thick Wall Sheathing Mantel and Wall ProjectionsCombustible Mantels IN. Thick Wall Sheathing12 Non-Combustible Zone Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Covered Alcove ApplicationsVent Information and Diagrams Top Vent Horizontal Termination Venting with 1 elbow Top Vent Horizontal Termination Venting with 2 elbows SLR-B Top Vent Horizontal Termination Venting with 3 elbowsInstalled Horizontally Exhaust restrictor Instructions Top Vent Vertical Termination No Elbows V1 = 44 ft. Max .4 mV1 Minimum Maximum V1 + V2 Minimum Top Vent Vertical Termination Venting with 2 elbowsTop Vent Vertical Termination Venting with 3 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MIN Top Vent Vertical Termination Venting with 4 elbowsTermination Cap Flue Damper Prior to installing the gas applianceCoaxial to Colinear Venting Clearances to CombustiblesTermination CAP Inlet AIR Vent Pipe Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Floor HearthCombustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe SLP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Top Vent Appliance PreparationProper Positioning, Leveling And Securing Of An Securing and Leveling the ApplianceAssemble Vent Sections Installing Vent Pipe SLP PipeSecure The Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components 17 Venting through the wall Install Horizontal Termination CapGas Pressure Access Through the Valve AssemblyGas Information Fuel ConversionDisconnect Gas Valve Gas ConnectionElectrical Information Wiring RequirementsOptional Accessories Requirements IntelliFire Ignition System WiringElectrical Service and Repair Junction Box Installation Non-Combustible Materials Specification FinishingFraming and Finishing Instructions Finishing InstructionsNON-COMBUSTIBLE Boar D Wallboard Joint-Crack Prevention and Repair Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard PaintingMAX Measurement 14 IN. from TOP of MIN. Fireplace Opening Combustible MantelsOverlap Fit Method Tonic or Martini Decorative Front Facing MaterialHeat & Glo SLR-B 2195-900 Rev. P 12/11 Decorative Fronts Dimensions of Tonic Decorative FrontAppliance Setup Pilot Shield Air Shutter Settings Install the MeshAir Shutter Setting IntelliFire Ignition System TroubleshootingSymptom Possible Cause Corrective Action With fi xed glass assembly in place, verify that fl ame is en Reference Materials Appliance Dimension DiagramDVP-BEK2 Vent Components DiagramsDRC-RADIUS COOL-ADDCeiling Firestop SLP-45 45 ElbowSLP90- 90 Elbow Extended Heat ShieldBlack 305 mm 178 mm 15-1/2 394 mm Snorkel Support Box-BlackAdapter SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP SLP-TRAPLINK-DV30B DVP-2SL DV-46DVA-GCL Optional Wire HarnessPVI-SLP SLP-LPCDo not Discard this Manual Contact Information

SLR-B (COSMO) specifications

The Heat & Glo LifeStyle SLR-B (COSMO) is a revolutionary gas fireplace that embodies modern design while prioritizing efficiency and sophistication. Known for its sleek lines and contemporary aesthetic, the SLR-B blends seamlessly into various home décors, making it a popular choice among homeowners who value both style and functionality.

One of the standout features of the SLR-B is its panoramic viewing glass. The expansive front glass panel offers an unobstructed view of the flames, creating a stunning focal point in any room. This design not only enhances the ambiance but also allows for a more radiant heat output, efficiently warming the space while inviting a captivating visual element into the home.

The SLR-B utilizes advanced burner technology, which ensures a clean and efficient burn, producing realistic flames that mimic the look of natural wood fires. The unique firebox design enhances combustion efficiency, maximizing heat output while minimizing emissions. This aligns with modern environmental standards and provides homeowners with peace of mind regarding their energy consumption.

Compatibility with home automation systems is another attractive aspect of the SLR-B. With options for remote control and smart technology integration, users can control the fireplace settings from anywhere in the home, providing convenience and comfort. The inclusion of adjustable flame height adds personalization, allowing users to create the ideal atmosphere based on their preferences.

Safety is paramount in the design of the SLR-B. The fireplace comes with a sealed combustion system, which prevents drafts and enhances indoor air quality by minimizing the infiltration of outside air. Additionally, an intuitive control system informs users of the fireplace's status and ensures the right operation settings, contributing to a safer user experience.

With customizable media options, including various decorative stones or logs, the SLR-B allows for personal expression, harmonizing the design with individual tastes. This versatility makes it suitable for diverse spaces, from modern apartments to traditional homes.

In summary, the Heat & Glo LifeStyle SLR-B (COSMO) combines cutting-edge technology with aesthetic appeal. Its panoramic design, eco-friendly combustion, smart technology integration, safety features, and customizable options make it a top choice for homeowners seeking a sophisticated heating solution that enhances their living spaces.