Heat & Glo LifeStyle SLR-B (COSMO) owner manual Gas Information, Fuel Conversion, Gas Pressure

Page 46

11 Gas Information

A. Fuel Conversion

Make sure the appliance is compatible with available gas types.

Conversions must be made by a qualified service technician using Hearth & Home Technologies specifi ed and approved parts.

B. Gas Pressure

Optimum appliance performance requires proper input pressures.

Gas line sizing requirements will be determined in ANSI Z223.1 National Fuel Gas Code in the USA and CAN/ CGA B149 in Canada.

Pressure requirements are:

Gas Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 in. w.c.

11.0 in. w.c.

Maximum inlet pressure

10.0 in. w.c.

13.0 in. w.c.

Manifold pressure

3.5 in. w.c.

10.0 in. w.c.

WARNING! Risk of Fire or Explosion! High pressure will damage valve. Low pressure may cause explosion.

Verify inlet pressures. Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

Note: This appliance does include a manual gas shutoff valve that is located in the valve compartment. This manual gas shutoff valve is accessible for service by removing the base pan, burner assembly and valve plate. See Figure 11.1.

The lower access cover panel is removable if finishing material has not been previously installed.

REMOVE SCREWS

BURNER CLIP

BASE PAN

Figure 11.1 Cover Tray Removal

Access Through the Valve Assembly

The lower access cover panel is removable if finishing material has not been previously installed.

Remove Media Tray, Burner Assembly, and Base pan. To access components:

1.Remove eleven screws around perimeter of valve plate that secure valve plate to the fi rebox bottom. See Figure 11.2.

2.Lift the valve plate from the back so that the gas valve can clear the valve plate hole in the bottom the fi rebox. See Figure 11.3.

Figure 11.2. Remove Valve Plate Screws

3.Set the valve bracket on the front lip of the fi rebox bot- tom. Turn “off” the ball valve. Disconnect gas valve from the gas fl ex ball valve assembly at the pressure fi tting. See Figure 11.4.

Figure 11.3. Remove Valve Plate

4.Lift the valve assembly up and out to make necessary service or repair.

46

Heat & Glo • SLR-B2195-900 Rev. P • 12/11

Image 46
Contents What to do if you smell gas ModelHOT Surfaces Congratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Decorative Doors and FrontsWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveIssue Solutions Frequently Asked QuestionsInitial Break-in Procedure After Fireplace is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection FireboxGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase Minimum Framing Dimensions ClearancesCombustible Mantels IN. Thick Wall Sheathing12 Mantel and Wall ProjectionsNon-combustible Mantels Thick Wall Sheathing Non-Combustible Zone Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Top Vent Horizontal Termination Venting with 1 elbow Top Vent Horizontal Termination Venting with 2 elbows Top Vent Horizontal Termination Venting with 3 elbows SLR-BInstalled Horizontally Top Vent Vertical Termination No Elbows V1 = 44 ft. Max .4 m Exhaust restrictor InstructionsTop Vent Vertical Termination Venting with 2 elbows V1 Minimum Maximum V1 + V2 MinimumTop Vent Vertical Termination Venting with 3 elbows Top Vent Vertical Termination Venting with 4 elbows V1 MIN H1 MAX V2 MIN H2 MAX V3 MINClearances to Combustibles Prior to installing the gas applianceCoaxial to Colinear Venting Termination Cap Flue DamperFloor Hearth Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Termination CAP Inlet AIR Vent PipeWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe SLPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Top VentSecuring and Leveling the Appliance Proper Positioning, Leveling And Securing Of AnInstalling Vent Pipe SLP Pipe Assemble Vent SectionsAssemble Slip Sections Secure The Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Decorative Wall Components Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 17 Venting through the wallFuel Conversion Access Through the Valve AssemblyGas Information Gas PressureGas Connection Disconnect Gas ValveIntelliFire Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical InformationElectrical Service and Repair Junction Box Installation Finishing Instructions FinishingFraming and Finishing Instructions Non-Combustible Materials SpecificationNON-COMBUSTIBLE Boar D Painting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard Wallboard Joint-Crack Prevention and RepairCombustible Mantels MAX Measurement 14 IN. from TOP of MIN. Fireplace OpeningFacing Material Overlap Fit Method Tonic or Martini Decorative FrontHeat & Glo SLR-B 2195-900 Rev. P 12/11 Dimensions of Tonic Decorative Front Decorative FrontsAppliance Setup Pilot Shield Air Shutter Setting Install the MeshAir Shutter Settings Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Ignition System With fi xed glass assembly in place, verify that fl ame is en Appliance Dimension Diagram Reference MaterialsCOOL-ADD Vent Components DiagramsDRC-RADIUS DVP-BEK2Extended Heat Shield SLP-45 45 ElbowSLP90- 90 Elbow Ceiling FirestopAdapter Snorkel Support Box-BlackBlack 305 mm 178 mm 15-1/2 394 mm SLP-TRAP SLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAPSLP-LPC Optional Wire HarnessPVI-SLP LINK-DV30B DVP-2SL DV-46DVA-GCLContact Information Do not Discard this Manual

SLR-B (COSMO) specifications

The Heat & Glo LifeStyle SLR-B (COSMO) is a revolutionary gas fireplace that embodies modern design while prioritizing efficiency and sophistication. Known for its sleek lines and contemporary aesthetic, the SLR-B blends seamlessly into various home décors, making it a popular choice among homeowners who value both style and functionality.

One of the standout features of the SLR-B is its panoramic viewing glass. The expansive front glass panel offers an unobstructed view of the flames, creating a stunning focal point in any room. This design not only enhances the ambiance but also allows for a more radiant heat output, efficiently warming the space while inviting a captivating visual element into the home.

The SLR-B utilizes advanced burner technology, which ensures a clean and efficient burn, producing realistic flames that mimic the look of natural wood fires. The unique firebox design enhances combustion efficiency, maximizing heat output while minimizing emissions. This aligns with modern environmental standards and provides homeowners with peace of mind regarding their energy consumption.

Compatibility with home automation systems is another attractive aspect of the SLR-B. With options for remote control and smart technology integration, users can control the fireplace settings from anywhere in the home, providing convenience and comfort. The inclusion of adjustable flame height adds personalization, allowing users to create the ideal atmosphere based on their preferences.

Safety is paramount in the design of the SLR-B. The fireplace comes with a sealed combustion system, which prevents drafts and enhances indoor air quality by minimizing the infiltration of outside air. Additionally, an intuitive control system informs users of the fireplace's status and ensures the right operation settings, contributing to a safer user experience.

With customizable media options, including various decorative stones or logs, the SLR-B allows for personal expression, harmonizing the design with individual tastes. This versatility makes it suitable for diverse spaces, from modern apartments to traditional homes.

In summary, the Heat & Glo LifeStyle SLR-B (COSMO) combines cutting-edge technology with aesthetic appeal. Its panoramic design, eco-friendly combustion, smart technology integration, safety features, and customizable options make it a top choice for homeowners seeking a sophisticated heating solution that enhances their living spaces.